ST0003-LR090420CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94081 163.0085 err
Service Date: 04/10/09 8901 Carpenter Frwy, Ste 100
Report Date: 04/20/09 Dallas, TX 75247
214 - 630 -1010 Reg No: F -3272
Client Project
City of Coppell TX Coppell Road - #ST00 -03
Attn: Albert Samaniego Sandy Lake Road to
Engineering Dept Cooper Lane
PO Box 9478 Coppell, TX
Coppell, TX 75019 Project Number: 94081163
Material Information Sample Information
Specified Strength: 4,000 psi @ 28 days
Mix ID: 2501 M
Supplier: Tiseo Paving
Batch Time: 0747
Truck No.: 181
Field Test Data
Test
Slump (in):
Air Content
Concrete Temp. (F):
Ambient Temp. (F):
Plant:
Ticket No.:
Result Specification
1
4.5
70
53
Plastic Unit Wt. (pcf): 152.8
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
Laboratory Test Data
Age at
Set Specimen Diameter
Area
Date
Date
Test
No. ID (in)
(sq in)
Received
Tested
(days)
1 1 6.00
28.27
04/11/09
04/17/09
7
1 2 6.00
28.27
04/11/09
05/08/09
28
1 3 6.00
28.27
04/11/09
05/08/09
28
04/10/09 Sample Time: 0800
Louis J. DeRossi
Sunny
80 Batch Size (cy): 10
Direct Discharge
0
0
Pavement at Sta. 19 +80
Southbound Coppell Road from Sta.
18 +00 to Sta. 35 +00
Maximum Compressive
Load Strength Fracture
(lbs) (psi) Type
153,620 5,430 4
Comments:
Samples Made By: Terracon
Services: Pick up test cylinders cast by others and return them to the laboratory for curing and testing.
Terracon Rep.: Louis J. DeRossi Started: 0600
Reported To: Finished: 1500
Contractor: Tiseo
Report Distribution:
(1) City or Cnppel I 'I'x (1) Huill Zol Inrs Inc
(1) Tisco Paving Cumpmiy
Test Methods: ASTM C 31, ASTM 09, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
(R -110"1 Page I Of'3 Revised 4/20/2009
CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94081 163.0085 e rr ..
Service Date: 04/10/09 8901 Carpenter Frwy, Ste 100
Report Date: 04/20/09 Dallas, TX 75247
214 -630 -1010 Reg No: F -3272
Client Project
City o1' Coppell TX Coppell Road - #ST00 -03
Attn: Albert Samaniego Sandy Lake Road to
Engineering Dept Cooper Lane
PO Box 9478 Coppell, TX
Coppell, TX 75019 Project Number: 94081163
Material Information Sample Information
Specified Strength: 4,000 psi @ 28 days
Mix ID: 2501 M
Supplier: Tiseo Paving
Batch Time: 0935 Plant:
Truck No.: 165 Ticket No.:
Field Test Data
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
04/10/09 Sample Time: 0950
Louis J. DeRossi
Sunny
260 Batch Size (cy): 10
Direct Discharge
0
0
Pavement at Sta. 25 +50
Southbound Coppell Road from Sta
18 +00 to Sta. 35 +00
Test
Slump (in):
Air Content ( %,):
Concrete Temp. (F):
Ambient Temp. (F):
Plastic Unit Wt. (pcf)
Result Specification
2
4.6
72
59
152.4
Laboratory Test Data
Age at
Maximum
Compressive
Set Specimen Diameter
Area
Date
Date
Test
Load
Strength Fracture
No. ID (in)
(sq in)
Received
Tested
(days)
(lbs)
(psi) Type
2 1 6.00
28.27
04/11/09
04/17/09
7
138,060
4,880 2
2 2 6.00
28.27
04/11/09
05/08/09
28
2 3 6.00
28.27
04/11/09
05/08/09
28
Comments:
Samples Made By: Terracon
Services: Pick up test cylinders cast by others and return them to the laboratory for curing and testing.
Terracon Rep.: Louis J. DeRossi Started: 0600
Reported To: Finished: 1500
Contractor: Tiseo
Report Distribution:
(1) city ol'C'oppell TX (1) Huilt Zollm's Inc
(I) Tiseo Paving Company
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
c tt -turn i Page 2 01' 3 Revised 4/20/2009
CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94081 163.0085 Irerracon
Service Date: 04/10/09 8901 Carpenter Frwy, Ste 100
Report Date: 04/20/09 Dallas, TX 75247
214 -630 -1010 Reg No: F -3272
Client Project
City of Coppell TX Coppell Road - #ST00 -03
Attn: Albert Samaniego Sandy Lake Road to
Engineering Dept Cooper Lane
PO Box 9478 Coppell, TX
Coppell, TX 75019 Project Number: 94081 163
Material Information Sample Information
Specified Strength: 4,000
psi @ 28 days
Sample Date:
04/10/09 Sample Time: 1155
Age at
Maximum
Sampled By:
Louis J. DeRossi
Mix ID: 2501 M
Date
Weather Conditions:
Sunny
Supplier: Tiseo Paving
Strength Fracture
Accumulative Yards:
470 Batch Size (cy): 10
Batch Time: 1 138
Plant:
Placement Method:
Direct Discharge
Truck No.: 186
Ticket No.:
Water Added Before (gal):
0
04/17/09
7
Water Added After (gal):
0
Field Test Data
28.27
Sample Location:
Pavement at Sta. 31 +00
Test Result Specification
Placement Location:
Southbound Coppell Road from Sta.
Slump (in):
2
04/11/09
18 +00 to Sta. 35 +00
Air Content (' %t):
4.6
Concrete Temp. (F):
70
Ambient Temp. (F):
60
Plastic Unit Wt. (pef):
152.8
Laboratory Test Data
Age at
Maximum
Compressive
Set Specimen Diameter
Area
Date
Date
Test
Load
Strength Fracture
No. ID (in)
(sq in)
Received
Tested
(days)
(lbs)
(psi) Type
3 1 6.00
28.27
04/11/09
04/17/09
7
138,500
4,900 2
3 2 6.00
28.27
04/11/09
05/08/09
28
3 3 6.00
28.27
04/11/09
05/08/09
28
Comments:
Samples Made By: Terracon
Services: Pick up test cylinders cast by others and return them to the laboratory for curing and testing.
Terracon Rep.: Louis .1. DeRossi Started: 0600
Reported To: Finished: 1500
Contractor: Tiseo
Report Distribution:
(1) City orCoppell'I\ (1)HuittZollarslnc Reviewed By:
(1) Tiseo Paving Company Eric J. Clev land, P.E.
Senior Proj Engineer
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
('It -nunl Page 3 oi'3 Rev Created 8/14P-007 4/202009