Loading...
ST0003-LR090408REPORT OF SOIL -LIME MIXTURE PULVERIZATION err Consulting Engineers & Scientists 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214- 630 -1010 Date of Service: 04/08/09 Client: City of Coppell TX Engineering Dept PO Box 9478 Coppell, TX 75019 Contractor: Tiseo Test Location: S. Bound Coppell Rd. Sta. 39 +00 - Sta. 52 +50 Test Method: NCTCOG Report No.: 94081163.0083 Project No.: 94081163 Project: Coppell Road - #ST00 -03 Sandy Lake Road to Cooper Lane Coppell, TX Specification Requirements: Minimum Passing 1 -3/4" Sieve: 100% Minimum Passing #4 Sieve: 60% Sample Condition: Field Moist TEST NO. LOCATION 1 -3/4" SIEVE % PASSING #4 SIEVE % PASSING 1 Sta. 39 +75, 10' L of centerline 100 78 2 Sta. 42 +75, 10' L of centerline 100 64 3 Sta. 44 +75, 10' L of centerline 100 69 4 Sta. 47 +25, 10'L of centerline 100 77 5 Sta. 49 +75, 10' L of centerline 100 77 6 Sta. 52 +25, 10'L of centerline 100 86 Comments: Technician: B. Hatch Report Distribution: (1) City of Coppell TX (1) City of Coppell TX (1) Huitt Zollars Inc (1) Tiseo Paving Company Eric J. Cleveland P.E. Senior Project Manager dgr This report is exclusively for the use of tie client indicated above and shall not be reproduced in full without written approval of Terracon.