Loading...
ST0003-LR090401CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94081163.0073 Irerracon Service Date: 03/03/09 8901 Carpenter Frwy, Ste 100 Report Date: 04/01/09 Dallas, TX 75247 214- 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 3,000 psi @ 28 days Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water. Added After (gal): Sample Location: Placement Location: 03/03/09 Sample Time: 1055 Mario A.Garcia Clear, Mild Breeze 10 Batch Size (cy): 10 Direct Discharge 10 0 Set #1, see attached sketch Sidewalk, northbound Coppell Rd; see attached sketch for placement area Mix ID: 8272 Supplier: TXI Batch Time: 0920 Plant: 141 Truck No.: 8004 Ticket No.: 835919 Field Test Data Test Result Slump (in): 5 Air Content ( %): 5.2 Concrete Temp. (F): 61 Ambient Temp. (F): 56 Specification Plastic Unit Wt. (pcf): 145.2 Laboratory Test Data Set Specimen Diameter Area Date No. ID (in) (sq in) Received 1 1 6.00 28.27 03/04/09 1 2 6.00 28.27 03/04/09 1 3 6.00 28.27 03/04/09 Age at Maximum Compressive Date Test Load Strength Fracture Tested (days) (lbs) (psi) Type 03/10/09 7 90,460 3,200 5 03/31/09 28 128,420 4,540 4 03/31/09 28 111,470 3,940 2 Average (28 days) 4,240 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Mario A.Garcia Started: 0900 Reported To: Contractor: Tiseo Report Distribution: (1) City of Coppell TX (1) Huitt Zollars Inc (1) Tiseo Paving Company Finished: 1200 Reviewed By: Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of I zk q US --Q V) I i 3A I T n E REPORT NO. -0 - 2- ,9 --o (IM CL SCkOL f& CAPE