Loading...
ST0003-LR090330CONCRETE COMPRES STRENGTH TEST REPORT Report Num Service Date: 02/27/09 8901 Carpenter Frwy, Ste 100 Report Date: 03/30/09 Dallas, TX 75247 214- 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 3,000 psi @ 28 days Mix ID: 8272 Supplier: TXI Batch Time: 0939 Plant: 141 Truck No.: 1137 Ticket No.: 834465 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 6 4.1 81 60 146.8 Laboratory Test Data Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: Set Specimen Diameter Area Date Date No. ID (in) (sq in) Received Tested 1 1 6.00 28.27 02/28/09 03/06/09 1 2 6.00 28.27 02/28/09 03/27/09 1 3 6.00 28.27 02/28/09 03/27/09 02/27/09 Sample Time: 1040 Louis J. DeRossi Overcast 10 Batch Size (cy): 10 Direct Discharge 15 0 Approximately @ Sta. 36 +00 Sidewalk from Sta. 35 +50 to Sta. 38 +95, Coppell Rd Age at Maximum Compressive Test Load Strength Fracture (days) (lbs) (psi) Type 7 98,390 3,480 2 28 136,570 4,830 4 28 130,950 4,630 4 Average (28 days) 4,730 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Louis J. DeRossi Started: 0930 Reported To: Contractor: Tiseo Report Distribution: (1) City of Coppell TX (1) Tiseo Paving Company (1) Huitt Zollars Inc Finished: 1130 Reviewed By: Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1