ST0003-LR090319CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94081163.0061 Service Date: 02/18/09 Report Date: 03/19/09 m irerracon 8901 Carpenter Frwy, Ste 100 Dallas, TX 75247 214- 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 2501H Supplier: Tiseo Paving Batch Time: 0815 Truck No.: 161 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plant: Ticket No.: Result Specification 4 3 -5 5.0 3 -6 70 55 Plastic Unit Wt. (pcf): 150.8 Laboratory Test Data Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: Set Specimen Diameter Area Date Date No. ID (in) (sq in) Received Tested 1 1 6.00 28.27 02/19/09 02/21/09 1 2 6.00 28.27 02/19/09 02/25/09 1 3 6.00 28.27 02/19/09 03/18/09 1 4 6.00 28.27 02/19/09 03/18/09 02/18/09 Sample Time: 0855 Louis J. DeRossi Sunny 80 Batch Size (cy): 10 Direct Discharge Sta. .31 +20 Coppell Rd, NB inside lane @ Sta. 28 +80 to Sta. 44 +45 Age at Maximum Compressive Test Load Strength Fracture (days) (lbs) (psi) Type 3 94,850 3,360 6 7 115,680 4,090 4 28 144,890 5,120 2 28 149,750 5,300 2 Average (28 days) 5,210 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Louis J. DeRossi Reported To: Contractor: Tiseo Report Distribution: (1) City of Coppell TX (1) Tiseo Paving Company (1) Huitt Zollars Inc Started: 0700 Finished: 1700 Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page] of 3 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94081163.0061 Service Date: 02/18/09 Report Date: 03/19/09 "Irerracon 8901 Carpenter Frwy, Ste 100 Dallas, TX 75247 214 - 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 2501H Supplier: Tiseo Paving Batch Time: 1041 Truck No.: 165 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plant: Ticket No.: Result Specification 5 3 -5 5.8 3 -6 72 65 Plastic Unit Wt. (pcf): 150.0 Laboratory Test Data Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: Set Specimen Diameter Area Date Date No. ED (in) (sq in) Received Tested 2 1 6.00 28.27 02/19/09 02/21/09 2 2 6.00 28.27 02/19/09 02/25/09 2 3 6.00 28.27 02/19/09 03/18/09 2 4 6.00 28.27 02/19/09 03/18/09 02/18/09 Sample Time: 1110 Louis J. DeRossi Sunny 220 Batch Size (cy): 10 Direct Discharge 0 0 Sta. 38 +20 Coppell Rd, NB inside lane @ Sta. 28 +80 to Sta. 44 +45 Age at Maximum Compressive Test Load Strength Fracture (days) (lbs) (psi) Type 3 93,650 3,310 6 7 120,830 4,270 4 28 156,560 5,540 2 28 146,530 5,180 2 Average (28 days) 5,360 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Louis J. DeRossi Reported To: Contractor: Tiseo Report Distribution: (1) City ofCoppell TX (1) Tiseo Paving Company (1) Huitt Zollars Inc Started: 0700 Finished: 1700 Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94081163.0061 Service Date: 02/18/09 Report Date: 03/19/09 Client Project Terracon 8901 Carpenter Frwy, Ste 100 Dallas, TX 75247 214- 630 -1010 City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 2501H Supplier: Tiseo Paving Batch Time: 1306 Plant: Truck No.: 161 Ticket No.: Field Test Data Test Result Slump (in): 5 Air Content ( %): 5.2 Concrete Temp. (F): 80 Ambient Temp. (F): 70 Plastic Unit Wt. (pcf): 150.4 Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: 02/18/09 Sample Time: 1330 Louis J. DeRossi Sunny 370 Batch Size (cy): 10 Direct Discharge 0 0 Sta. 41 +20 Coppell Rd, NB inside lane @ Sta. 28 +80 to Sta. 44 +45 Specification 3 -5 3 -6 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 3 1 6.00 28.27 02/19/09 02/21/09 3 71,120 2,520 6 3 2 6.00 28.27 02/19/09 02/25/09 7 135,680 4,800 3 3 3 6.00 28.27 02/19/09 03/18/09 28 167,890 5,940 4 3 4 6.00 28.27 02/19/09 03/18/09 28 173,230 6,130 4 Average (28 days) 6,040 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Louis J. DeRossi Started: 0700 Reported To: Finished: 1700 Contractor: Tiseo Report Distribution: (1) City of Coppell TX (1) Huitt Zollars Inc Reviewed By: (1) Tiseo Paving company JAric J. Cleveland, P.E. Senior Project Engineer Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3