Loading...
ST0003-LR090220CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94081163.0046 I rerracon Service Date: 01/22/09 8901 Carpenter Frwy, Ste 100 Report Date: 02/20/09 Dallas, TX 75247 214 -630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 28 days Mix ID: 2501H Supplier: TISEO Paving Batch Time: 0917 Plant: Truck No.. 165 Ticket No.: N/A Field Test Data Test Result Slump (in): 3 Air Content (' %): 4.7 Concrete Temp. (F): 63 Ambient Temp. (F): 70 Plastic Unit Wt. (pef): 150.8 Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal) Water Added After (gal): Sample Location: Placement Location: 01/22/09 Sample Time: 0935 Gregory L. Warren Clear 70 Batch Size (cy): 10 Direct Discharge 0 0 See Placement Location Pavement Leaveouts, see attached sketch Specification Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. 1D (in) (sq in) Received Tested (days) (Ibs) (psi) Type 1 1 6.00 28.27 01/23/09 01/29/09 7 153,270 5,420 4 1 2 6.00 28.27 01/23/09 02/19/09 28 216,260 7,650 2 1 3 6.00 28.27 01/23/09 02/19/09 28 211,380 7,480 2 Average (28 days) 7,570 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples, Terracon Rep.: Gregory L. Warren Repurted To: Contractor: Tiseo Report Distribution: (1) City of Coppell TX (1) Huitt Zollars Inc (1) Tiseo Paving Company Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94081163.0046 err Service Date: 01/22/09 8901 Carpenter Frwy, Ste 100 Report Date: 02/20/09 Dallas, TX 75247 214- 630 -1010 Client Project City of Coppell TX Attn: Albert Samaniego Engineering Dept PO Box 9478 Coppell, TX 75019 Coppell Road - #ST00 -03 Sandy Lake Road to Cooper Lane Coppell, TX Project Number: 94081163 Material Information Specified Strength: 28 days Mix ID: 2501H Supplier: TiSEO Paving Batch Time: 1 148 Plant: Truck No.: 163 Ticket No.: N/A Field Test Data Test Result Specification Slump (in): 3 3/4 Air Content (%): 4.5 Concrete Temp. (F): 68 Ambient Temp. (F): 78 Plastic Unit Wt. (pcf): 150.4 Sample Information Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: 01/22/09 Sample Time: 1230 Gregory L. Warren Clear 140 Batch Size (ey): 10 Direct Discharge 0 0 See Placement Location Pavement Leaveouts; see attached sketch Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 2 1 6.00 28.27 01/24/09 01/29/09 7 133,260 4,710 2 2 2 6.00 28.27 01/24/09 02/19/09 28 169,580 6,000 2 2 3 6.00 28.27 01/24/09 02/19/09 28 172,810 6,110 2 Average (28 days) 6,060 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Teri-aeon Services: Obtain samples of fresh concrete at the placement locations, perform required fie samples. Terracon Rep.: Gregory L. Warren Reported To: Contractor: Tiseo Report Distribution: (1) City of Coppell TX (1) Huitt Zollars Inc Reviewed By: (1) Tisco Paving Company Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 Senior Project Manager TERRACON REPORT NO. PROJECT C/ r � PROJECT NO.: 9 I N? 1163' O y 1 Consulting Engineers & Scientists C- CGE►v6 1 (oCtifzn, S