Loading...
ST0003-LR090219 (2)CONCRETE COMPRESSIVE STRENGTH TEST REPORT "Irerracon Report Number: 94081163.0044 Age at Maximum Compressive Set Specimen Diameter Area Date Service Date: 01/21/09 Test Load Strength Fracture 8901 Carpenter Frwy, Ste 100 Report Date: 02/19/09 Received Tested (days) (lbs) Dallas, TX 75247 Type 1 1 6.00 28.27 01/22/09 214- 630 -1010 Client 4,480 2 Project 28.27 City of Coppell TX 02/18/09 28 183,030 Coppell Road - #ST00 -03 2 Attn: Albert Snmaniego 28.27 01/22/09 Sandy Lake Road to 28 170,160 Engineering Dept 2 Cooper Lane PO Box 9478 Average (28 days) 6,250 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 4,000 psi a 28 days Sample Date: 01/21/09 Sample Time: 1130 Sampled By: Ashton L. Varnell Mix ID: 8274 Weather Conditions: Clear, light winds Supplier: TX1 Accumulative Yards: 10 Batch Size (cy): 10 Batch Time: 1033 Plant: 141 Placement Method: Direct Discharge Truck No.: 1070 Ticket No.: 815324 Water Added Before (gal): 10 Water Added After (gal): 0 Field Test Data Sample Location: Driveway, 404 Coppell Test Result Specification Placement Location: Pavement, driveway @ 404 Coppell and Slump (in): 4 1/4 curb, 15' each way from inlet @ 406 Air Content (°/,): 5.2 Coppell Concrete Temp. (F): 78 Ambient Temp. (F): 62 Plastic Unit Wt. (pef): 146.0 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 01/22/09 01/28/09 7 126,790 4,480 2 1 2 6.00 28.27 01/22/09 02/18/09 28 183,030 6,470 2 1 3 6.00 28.27 01/22/09 02/18/09 28 170,160 6,020 2 Average (28 days) 6,250 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive stren samples. Terracon Rep.: Ashton L. Varnell Reported To: Contractor: Tiseo Report Distribution: (1) City ol'Coppell TX (1) Huiu Zollars Inc . Reviewed By: lel — (1) Tiseo Paving Company Eric J leveland, P.E. Seniv Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page t of I