Loading...
ST0003-LR090206CON COMPRESSIVE STRENGTH TEST REPORT . Report Number: 94081 163.0048 Service Date: 01/23/09 8901 Carpenter Frwy, Ste 100 Report Date: 02/06/09 Dallas, TX 75247 214- 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 3000 psi @ 28 days Mix ID: 8272 Supplier: TXI Batch Time: 1 122 Plant: 141 Truck No.: 1 109 Ticket No.: 817248 Field Test Data Test Result Specification Slump (in): 4 314 Air Content 5.6 Concrete Temp. (F): 67 Ambient Temp. (F): 74 Plastic Unit Wt. (pef): 144.4 Laboratory Test Data Set Specimen Diameter Area Date No. I D (in) (sq in) Received 1 1 6.00 28.27 01/24/09 1 2 6.00 28.27 01/24/09 1 3 6.00 28.27 01/24/09 Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: 01/23/09 Sample Time: 1207 Christopher P. Moran Partly cloudy 10 Batch Size (cy): 10 Direct Discharge 0 0 See Placement Location Sidewalk, Coppell Rd & Ruby, E side going south 2 blocks Age at Maximum Compressive Date Test Load Strength Fracture Tested (days) (lbs) (psi) Type 01/30/09 7 111,530 3,950 2 02/20/09 28 02/20/09 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cas compressive strength samples. /�� Terracon Rep.: Christopher P. Moran Started: 1030 /� �, Reported To: Contractor: Tiseo Report Distribution: (1) City of Coppell TX (1) Tiseo Paving Company (1) Huitt Zollars Inc Finished: 1230 Reviewed By: SeniolfProject Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of I