ST0003-LR090206CON COMPRESSIVE STRENGTH TEST REPORT .
Report Number: 94081 163.0048
Service Date: 01/23/09 8901 Carpenter Frwy, Ste 100
Report Date: 02/06/09 Dallas, TX 75247
214- 630 -1010
Client Project
City of Coppell TX Coppell Road - #ST00 -03
Attn: Albert Samaniego Sandy Lake Road to
Engineering Dept Cooper Lane
PO Box 9478 Coppell, TX
Coppell, TX 75019 Project Number: 94081163
Material Information Sample Information
Specified Strength: 3000 psi @ 28 days
Mix ID: 8272
Supplier: TXI
Batch Time: 1 122 Plant: 141
Truck No.: 1 109 Ticket No.: 817248
Field Test Data
Test
Result Specification
Slump (in):
4 314
Air Content
5.6
Concrete Temp. (F):
67
Ambient Temp. (F):
74
Plastic Unit Wt. (pef): 144.4
Laboratory Test Data
Set Specimen Diameter
Area
Date
No. I D (in)
(sq in)
Received
1 1 6.00
28.27
01/24/09
1 2 6.00
28.27
01/24/09
1 3 6.00
28.27
01/24/09
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
01/23/09 Sample Time: 1207
Christopher P. Moran
Partly cloudy
10 Batch Size (cy): 10
Direct Discharge
0
0
See Placement Location
Sidewalk, Coppell Rd & Ruby, E side
going south 2 blocks
Age at Maximum Compressive
Date
Test Load
Strength Fracture
Tested
(days) (lbs)
(psi) Type
01/30/09
7 111,530
3,950 2
02/20/09
28
02/20/09
28
Comments:
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cas compressive strength
samples. /��
Terracon Rep.: Christopher P. Moran Started: 1030 /� �,
Reported To:
Contractor: Tiseo
Report Distribution:
(1) City of Coppell TX
(1) Tiseo Paving Company
(1) Huitt Zollars Inc
Finished: 1230
Reviewed By:
SeniolfProject Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Page I of I