ST0003-LR090130CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94081 163.0040 Ireirracon Service Date: 01/19/09 8901 Carpenter Frwy, Ste 100 Report Date: 01/30/09 Dallas, TX 75247 214- 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 3600 psi @ 28 days Mix ID: 9339 Supplier: Southern Star Concrete Batch Time: 1330 Plant: I 1 1 True[( No.: 9027 Ticket No.: 0144.0687 Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal) Water Added After (gal): Sample Location: Placement Location: Field Test Data Test Slump (in): Air Content ("o): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pef): Result 5 5.6 72 64 144.6 Specification Laboratory Test Data Set Specimen Diameter Area Date No. ID (in) (sq in) Received 1 1 6.00 28.27 01/20/09 1 2 6.00 28.27 01/20/09 1 3 6.00 28.27 01/20/09 01/19/09 Sample Time: 1437 Juan Lopez Sunny, mild winds 7 Batch Size (ey): 7 Direct Discharge 0 0 Inlet approach @ Sta. 0 +12 Inlet approach @ Sta. 0 +12.68; Inlet walls @ Sta. 0 +14.45 Age at Maximum Compressive Date Test Load Strength Fracture Tested (days) (lbs) (psi) Type 01/26/09 7 90,790 3,210 2 02/16/09 28 02/16/09 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast compressive strength samples. Terracon Rep.: Juan Lopez Started: 1330 Reported To: Contractor: Tiseo Report Distribution: (1) City of Coppell 1'x (I) Tiseo Paving Cumpnny (1) Huitt Zollars Inc Finished: 1530 Reviewed By: Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 o l' I Senior Project Engineer CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94081 163.0044 Service Date: 01/21/09 Report Date: 01/30/09 Irerracon 8901 Carpenter Frwy, Ste 100 Dallas, TX 75247 214- 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 4000 psi @ 28 days Mix ID: 8274 Supplier: TX1 Batch Time: 1033 Plant: 141 Truck No.: 1070 Ticket No.: 815324 Field Test Data • Test Result Specification Slump (in): 41/4 Air Content 5.2 Concrete Temp. (F): 78 Ambient Temp. (F): 62 Plastic Unit Wt. (pef): 146.0 Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: 01/21/09 Sample Time: 1 130 Ashton L. Varnell Clear, light winds 10 Batch Size (cy): 10 Direct Discharge 10 0 Driveway, 404 Coppell Pavement, driveway @ 404 Coppell and curb, 15' each way from inlet@ 406 Coppell Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 01/22/09. 01/28/09 7 126,790 4,480 2 1 2 6.00 28.27 01/22/09 02/18/09 28 1 3 6.00 28.27 01/22/09 02/18/09 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Ashton L. Varnell Reported To: Contractor: Tiseo Report Distribution: (1) City of Coppel [Tx (I) Tisco Pavin, Comp my Test Methods: (1) Huitt Zollnrs Inc Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM.C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of I Senior Project Manager FIELD DENSITY TEST REPORT Irerracon Report Number: 94081163.0045 Service Date: 01/21/09 8901 Carpenter Frwy, Ste 100 Report Date: 01/30/09 Dallas, TX 75247 214- 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Lab Test Data Project Requirements Optimum Max. Lab Water Dry Unit Water Minimum Mat. Proctor Laboratory Content Weight Content Compaction No. Ref. No. Classification and Description Test Method ( %) (pef) ( %) ( %) 1 94081 163.0007 Tan and gray sandy silty clay ASTM D698 14.1 116.1 0/ +4 95 Field Test Data Probe Wet Water Water Dry Unit Percent Test Lift / ,Mat. Depth Density Content Content Weight Compaction No. Test Location Elev. No. (in) (pef) (pcf) ( %) (pcf) ( %) 42" Storm Line 65 15'N of S entrance to school Final 1 6 133.3 18.5 16.1 114.8 99 36" Storm Line 66 15' S of S entrance to school Final 1 6 132.1 16.7 14.5 115.4 99 Gauge ID: 31787 Comments: Test results on this report meet project requirements as noted above. Services: Terracon Rep.: Bradley W. Hatch Started: 1030 Reported To: Brandon -NTC Finished: 1200 Contractor: Tiseo Report Distribution: (1) City or Coppell 'I'x (1) Huill Whirs lnc Reviewed By: (1) risen I'aviup Company Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of I