ST0003-LR090126CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94081 163.0030 Service Date: 12/24/08 Report Date: 01/26/09 "Ireirracon 8901 Carpenter Frwy, Ste 100 Dallas, TX 75247 214 - 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081 163 Material Information Sample Information Specified Strength: 4000 psi rr 28 days Mix ID: 2501h Supplier: Tiseo Paving Co Batch Time: 0851 Plant: N/A Truck No.: N/A Ticket No.: N/A Field Test Data Test Stamp (in): Air Content (` %o): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pef): Result Specification 6 1/2 3 -5 4.5 3 -6 65 55 148.0 Laboratory Test Data Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: Set Specimen Diameter Area Date Date No. I D (in) (sq in) Received Tested 1 1 6.00 28.27 12/26/08 12/31/08 1 2 6.00 28.27 12/26/08 01/21/09 1 3 6.00 28.27 12/26/08 01/21/09 12/24/08 Sample Time: 1000 Louis J. DeRossi Sunny 100 Batch Size (cy): 10 Conveyor 0 0 See Placement Location Approach @ Sta. 10 +80 Age at Maximum Compressive Test Load Strength Fracture (days) (lbs) (psi) Type 7 114,520 4,050 5 28 150,210 5,310 2 28 145,620 5,150 2 Average (28 days) 5,230 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fi concrete at the placement locations perform required field tests and cast compressive strength samples. Terracon Rep.: Louis J. DeRossi Reported To: Contractor: Tiseo Report Distribution: (1) City ol'Coppell Tx (1) Huitt Zollars me (I ) Tisco Paving Company Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I ol'2 CONCRETE COMPRESSIVE STRENGTH TEST REPORT EM EM Report Number: 94081 163.0030 iierracon Service Date: 12/24/08 8901 Carpenter Frwy, Ste 100 Report Date: 01/26/09 Dallas, TX 75247 214 -630 -1010 Client Project City of Coppel I TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 4000 psi @ 28 days Sample Date: 12/24/08 Sample Time: 1145 Maximum Compressive Sampled By: Louis J. DeRossi Mix ID: 2501 h Date Test Weather Conditions: Sunny Supplier: Tiseo Paving Co No. ID (in) Accumulative Yards: 170 Batch Size (cy): 10 Batch Time: 1032 Plant: N/A Placement Method: Type Truck No.: N/A Ticket No.: N/A Water Added Before (gal): 0 133,780 4,730 4 Water Added After (gal): 0 Field Test Data 01/21/09 28 Sample Location: See Placement Location Test Result Specification Placement Location: Approach @ Sta. 17 +25 Slump (in): 5 3 -5 2 Air Content (' %o): 4.5 3 -6 Average (28 days) 6,150 Concrete Temp. (F): 67 Ambient Temp. (F): 57 Plastic Unit Wt. (pcf): 148.0 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 2 1 6.00 28.27 12/26/08 12/31/08 7 133,780 4,730 4 2 2 6.00 28.27 12/26/08 01/21/09 28 173,580 6,140 2 2 3 6.00 28.27 12/26/08 01/21/09 28 174,060 6,160 2 Average (28 days) 6,150 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast co p s' strength samples. Terracon Rep.: Louis .I. DeRossi Reported To: Contractor: Tiseo Report Distribution: (1) City of Coppel I 'I'x (1) Huitt Zollnrs Inc Reviewed By: (1) Tice„ 1 1 av11e C ,,,,, 1 , any Eric J. Cleveland, P.E. Senior Project Engineer Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2