Loading...
ST0003-LR090107CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94081 163.0030 Service Date: 12/24/08 Report Date:. 01/07/09 Client Project "Ireirracon 8901 Carpenter Frwy, Ste 100 Dallas, TX 75247 214 - 630 -1010 City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 4000 psi @ 28 days Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: 12/24/08 Sample Time: 1000 Louis J. DeRossi Sunny 100 Batch Size (ey): 10 Conveyor 0 0 See Placement Location Approach @ Sta. 10 +80 Mix ID: 2501h Supplier: Tiseo Paving Co Batch Time: 0851 Plant: N/A Truck No.: N/A Ticket No.: N/A Field Test Data Test Result Slump (in): 6 1/2 Air Content (' %p): 4.5 Concrete Temp. (F): 65 Ambient Temp. (F): 55 Specification 3 -5 3 -6 Plastic Unit Wt. (pcf): 148.0 Laboratory Test Data Set Specimen Diameter Area Date No. ID (in) (sq in) Received I 1 6.00 28.27 12/26/08 2 6.00 28.27 12/26/08 3 6.00 28.27 12/26/08 Age at Maximum Compressive Date Test Load Strength Fracture Tested (days) (lbs) (psi) Type 12/31/08 7 114,520 4,050 5 01/21/09 28 01/21/09 28 Comments: Samples Made Lay: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast compressive strength samples. Terracon Rep.: Louis J. DeRossi Reported To: Contractor: Tiseo Report Distribution: (1) City or coppull 'rx (1) Huitt Zollars Inc (1) Tiseo Paving Company Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of 2 CONCRETE COMPRESSIVE STRENGTH TEST REPORT EM Report Number: 94081 163.0030 ooerracon Service Date: 12/24/08 8901 Carpenter Frwy, Ste 100 Report Date: 01/07/09 Dallas, TX 75247 214- 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 750.19 Project Number: 94081163 Material Information Sample Information Specified Strength: 4000 psi @ 28 days Mix ID: 2501h Supplier: Tiseo Paving Co Batch Time: 1032 Plant: N/A Truck No.: N/A Ticket No.: N/A Field Test Data Test Result Slump (in): 5 Air Content (` %o): 4.5 Concrete Temp. (F): 67 Ambient Temp. (P): 57 Specification 3 -5 3 -6 Plastic Unit Wt. (pcf): 148.0 Laboratory Test Data Set Specimen Diameter Area Date No. ID (in) (sq in) Received 2 1 6.00 28.27 12/26/08 2 ? 6.00 28.27 12/26/08 2 3 6.00 28.27 12/26/08 Sample Date: 12/24/08 Sample Time: 1145 Sampled By: Louis J. DeRossi Weather Conditions: Sunny Accumulative Yards: 170 Batch Size (ey): 10 Placement Method: 12/31/08 7 Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: See Placement Location Placement Location: Approach @ Sta. 17 +25 Age at Maximum Compressive Date Test Load Strength Fracture Tested (days) (lbs) (psi) Type 12/31/08 7 133,780 4,730 4 01/21/09 28 01/21/09 28 Comments: Samples Made By: Terracon Services: Obtain samples of flesh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Louis J. DeRossi Reported To: Contractor: Tiseo Report Distribution: (1) City nr Cnppcll TX (1) Huill Zollnrs Inc Reviewed By: (1) Tiseo 1 Company ri . Cleveland, P.E. Senior Project Engineer Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 LABORATORY COMPACTION CHARACTERISTICS OF SOIL am 00 Report Number: 94081163.0033 Herracon Service Date: 12/29/08 8901 Carpenter Frwy, Ste 100 Report Date: 01/07/09 Dallas, TX 75247 214- 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number 94081163 Material Information Source of Material: Treated on site Proposed Use: Paving subgrade Laboratory Test Data Test Procedure: ASTM D698 Test Method: Method A Sample Preparation: Wet Rammer Type: Mechanical Maximum Dry Unit Weight (pcf): 105.6 Optimum Water Content ( %): 19.6 108 107 Q 106 a+ 105 p� 104 N 103 102 101 5 100 99 p 98 97 Sample Information Sample Date: 12/29/09 Sampled By: Armando Rendon Sample Location: Coppell Road, Sta. 21 +00 Sample Description: Tan sandy clay (lime treated) Result Liquid Limit: 36 Plastic Limit: 29 Plasticity Index: 7 In -Place Moisture ( %): Specifications USCS: Zero Air Voids for Assumed Specific Gravity 2.65 - J- -.-t . 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Water Content ( %) Comments: Services: Moisture - Density Relations Terracon Rep: Armando Rendon Reported To: Contractor: Tiseo Report Distribution: (I ) City or Coppcll 'I :\ (I) Fluitt Zollars Inc (I) "risco Pavin Company Reviewed By: Eri eveland, P.E. Senior oject Engineer Test Methods: ASTM D698, ASTM D4318 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of I FIELD DENSITY TEST REPORT EM MM Report Number: 94081 163.0035 Service Date: 01/02/09 8901 Carpenter Frwy, Ste 100 Report Date: 01/07/09 Dallas, TX 75247 214- 630 -1010 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Lab Test Data Project Requirements Optimum Max. Lab Water Dry Unit Water Minimum Mat. Proctor Laboratory Content Weight Content Compaction No. Ref. No.' Classification and Description Test Method ( %) (pef) ( %) ( %) 1 94081 163.0033 Tan sandy clay (lime treated) ASTM D698 19.6 105.6 0/ +4 95 Field Test Data Probe Wet Water Water Dry Unit Percent Test Lift / Mat. Depth Density Content Content Weight Compaction No. Test Location Elev. No. (in) (pcf) (pef) ( %) (pcf) ( %) Paving, Coppell Road 56 Sta. 18 +00 Final 1 6 126.1 21.4 20.4 104.7 99 57 Sta. 21 -4-00 Final 1 6 126.0 20.8 19.8 105.2 100 58 S1a.24 +00 Final 1 6 125.5 21.0 20.1 104.5 99 59 Sta. 26-F00 Final 1 6 126.2 20.7 19.6 105.5 100 60 Sta. 28-1-00 Final 1 6 126.4 22.1 21.2 104.3 99 61 Sta. 31 +00 Final 1 6 126.1 21.5 20.6 104.6 99 Gauge 1D: 35366 Comments: Test results on this report meet project requirements as noted above. Services: Perform in -place density and moisture content tests to determine degree of compactbn and material moisture condition. Terracon Rep.: Armando Rendon Reported To: Contractor Contractor: Tiseo Report Distribution: (1) Cily 01' Coppell Tx (1) Huill Zollars Inc Reviewed By: (1) Tiseo Paving Company Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of I Senior Project Engineer