ST0003-LR081223CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94081 163.0024 Ireirracon
Service Date: 12/11/08 8901 Carpenter Frwy, Ste 100
Report Date: 12/23/08 Dallas, TX 75247
214 -630 -1010
Client Project
City of Coppel I TX Coppell Road - #ST00 -03
Attn: Albert Samaniego Sandy Lake Road to
Engineering Dept Cooper Lane
PO Box 9478 Coppell, TX
Coppell, TX 75019 Project Number: 94081163
Material Information Sample Information
Specified Strength: 4000 psi @ 28 days
Mix ID: 9339
Supplier: Southern Star
Batch Time: 1455 Plant: I I 1
Truck No.: 3553 Ticket No.: 1423036
Field Test Data
Test
Result Specification
Slump (in):
2
Air Content (%)):
3.0
Concrete Temp. (F):
61
Ambient Temp. (F):
68
Plastic Unit Wt. (pef): 148.8
Laboratory Test Data
Set Specimen Diameter Area Date
No. I D (in) (sq in) Received
1 1 4.00 12.57 12/13/08
2 4.00 12.57 12/13/08
3 4.00 12.57 12/13/08
(1) Huitt Zollms Inc
Comments:
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Bradley W.1-latch Started: 1430
Reported To:
Contractor: Tiseo
Report Distribution:
(1) City of C'oppcll Tx
(1) Tisco Pavint: Compally
Test Methods
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
12/11/08 Sample Time: 1545
Bradley W.Hatch
Clear
7.5 Batch Size (cy): 7.5
Direct Discharge
0
0
See Placement Location
Inlet bottoms and walls; Lateral A -8,
Sta. 0 +12; Lateral A -5, Sta. 0+ 12
Age at
Maximum
Compressive
Date Test
Load
Strength Fracture
Tested (days)
(lbs)
(psi) Type
12/18/08 7
57,080
4,540 2
01/08/09 28
01/08/09 28
Finished: 1630
Reviewed By:
Senidr Project Engineer
ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only, applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Page I of 1