Loading...
ST0701-LR100318CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091193.0095 Irerracon Service Date: 02/18/10 8901 Carpenter Frwy. Report Date: 03/18/10 Revision 2 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client City of Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Project Southwestern Boulevard Coppell Road to Grapevine Creels Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: DCCOG504 Supplier: Redi -Mix Batch Time: 1335 Plant: 259 Truck No.: 1028 Ticket No.: 25164077 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 3 1/2 3 -5 4.0 3 -6 74 68 146.0 Laboratory Test Data Set Specimen No. ID 3 4 Diameter Area (in) (sq in) 6.00 28.27 6.00 28.27 6.00 28.27 6.00 28.27 Sample Date: 02/18/10 Sample Time: 1440 Sampled By: Francisco J. Morillo Weather Conditions: Clear Accumulative Yards: 5 Batch Size (cy): 5 Placement Method: Direct Discharge Water Added Before (gal):0 (lbs) Water Added After (gal): 0 Sample Location: Approximately 50' W of E end Placement Location: Bridge Guard Rail Wall, south side Compressive Obtain samples of fresh concrete at the placement locations, perform required fie. Age at Maximum Date Date Test Load Received Tested (days) (lbs) 02/19/10 02/25/10 7 119,620 02/19/10 03/04/10 14 126,530 02/19/10 03/18/10 28 149,640 02/19/10 03/18/10 28 145,020 Average (28 days) Compressive Obtain samples of fresh concrete at the placement locations, perform required fie. Strength Fracture (psi) Type 4,230 4 4,480 4 5,290 4 5,130 5 5,210 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required fie. samples. Terracon Rep.: Francisco J. Morillo Started: 1330 Reported To: Superintendent Finished: 1630 Contractor: Lacy Construction Report Distribution: Reviewed By: (1) City of Coppell TX (1) City of Coppell TX (1) City of Coppell TX (2) Halff Assoc Inc (1) Lacy Construction (1) PacTrust Pacific Realty Associates LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5- 21 -09, Rev.3 Page 1 of 1 Senior Project Manager