Loading...
ST0702-LR100205CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091174.0083 Irey-racon Service Date: 01/22/10 8901 Carpenter Frwy. Report Date: 02/05/10 Revision 1 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Specified Strength: 3,600 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1 128 Plant: 7 Truck No.: 9142 Ticket No.: 3273282 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf) Result Specification 4 1/4 3 -5 4.2 3 -6 68 61 148.7 Laboratory Test Data Sample Information Specimen Sample Date: 01/22/10 Sample Time: 1206 Sampled By: Barry Cuble Weather Conditions: Sunny, breezy Accumulative Yards: 110 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):0 1 Water Added After (gal): 0 Sample Location: Eastbound lane, 12'N of S curb, 15' E 2 of W edge Placement Location: Paving, driveways on Howe at 708, 01/23/10 709, 710, 713, 717 and 821, eastbound 2 at Burns, E of Coppell Road Set Specimen Diameter Area Date Date No. ID (in) (sq in) Received Tested 2 1 6.00 28.27 01/23/10 01/25/10 2 2 6.00 28.27 01/23/10 01/29/10 2 3 6.00 28.27 01/23/10 02/05/10 2 4 6.00 28.27 01/23/10 02/19/10 2 5 6.00 28.27 01/23/10 02/19/10 Age at Maximum Compressive Test Load Strength Fracture (days) (lbs) (psi) Type 3 88,740 3,140 5 7 128,310 4,540 2 14 162,650 5,750 2 28 28 Comments: - Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Barry Cuble Started: 0530 Lunch/ Non - Chargeable: 2.00 Reported To: Finished: 1230 Contractor: JRJ Paving Report Distribution: Reviewed B (1) City of Coppell TX (1) Freese and Nichols Inc y (1) JR.I Paving LP c C eveland, P.E. Senior Pr oject Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. C11000 1, 5- 21 -09, Rev.l Page 2 of 2 R ONCR mb E . COMPRESSIVE STRENGTH TEST REPORT Ireoprocan Service Date: 01/22/10 8901 Carpenter Frwy. Report Date: 02/05/10 Revision I Dallas, TX 75247 214- 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 3,600 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 0704 Plant: 7 Truck No.: 7003 Ticket No.: 7214136 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (Pei): Result Specification 4 3 -5 3.6 3 -6 60 48 151.5 Laboratory Test Data Set Specimen Diameter No. ID (in) 1 1 6.00 1 2 6.00 1 3 6.00 1 4 6.00 mments: Samples Made By: Terracon Area Date (lbs) Test 114,390 4,050 2 132,430 4,680 2 Received 01/23/10 Sample Date: 01/22/10 Sample Time: 0734 Sampled By: Barry Cuble Weather Conditions: Sunny, light breeze Accumulative Yards: 20 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal): 10 Water Added After (gal): 0 Sample Location: 710 Howe, 10' N of S curb, 5'E of W edge Placement Location: Paving, driveways on Howe at 708, 709, 710, 713, 717 and 821, eastbound at Burns, E of Coppell Road Age at Date 02/05/10 02/19/10 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 114,390 4,050 2 132,430 4,680 2 Age at Tested 02/19/10 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 114,390 4,050 2 132,430 4,680 2 Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Barry Cuble Started: 0530 Lunch/ Non - Chargeable: 2.00 Reported To: Finished: 1230 Contractor: JRJ Paving Report Distribution: (1) City of Coppell TX (1) Freese and Nichols Inc MJRJ Paving LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5- 21 -09, Rcv.J Page I of 2