ST0702-LR100127CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091174.0078 Irerracon Service Date: 01/13/10 8901 Carpenter Frwy. Report Date: 01/27/10 Revision I Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Sample Date: 01/13/10 Sample Time: Sampled By: John Halverson Mix ID: 1701 Weather Conditions: Clear Supplier: Lattimore Accumulative Yards: 10 Batch Size (cy): Batch Time: Plant: 07 Placement Method: Direct Discharge Truck No.: 9115 Ticket No.: 7213807 Water Added Before (gal):0 Water Added After (gal): 0 Field Test Data Sample Location: North of railroad tracks Test Result Specification Placement Location: Two inlets at northbound side of road Slump (in): 5 1/2 Air Content ( %): 3.8 Concrete Temp. (F): 55 Ambient Temp. (F): 40 Plastic Unit Wt. (pcf): Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 01/14/10 01/20/10 7 152,120 5,380 2 1 2 6.00 28.27 01/14/10 01/27/10 14 165,740 5,860 4 1 3 6.00 28.27 01/14/10 02/10/10 28 1 4 6.00 28.27 01/14/10 02/10/10 28 Comments: Not tested for plastic unit weight. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast ompressive strength samples. Terracon Rep.: Terry Smith Insp /Testing Started: 1400 Reported To: Finished: 1730 Conti - actor: JRJ Paving Report Distribution: (1) City of Coppell TX (1) Freese and Nichols Inc Reviewed By: (1) JRJ Paving LP Eric J. Cleveland, P.E. Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001. 5- 21 -09, Rev .3 Page 1 of I CONCRETE COMPRESSIVE STRENGTH TEST REPORT EM am Report Number: 94091 174.0081 lerracon Service Date: 01/19/10 8901 Carpenter Frwy. Report Date: 01/27/10 Dallas, TX 75247 214 - 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 3,600 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 0639 Plant: 3 Truck No.: 5023 Ticket No.: 3273054 Field Test Data Test Slump (in): Air Content (' %o): Concrete Temp. (F): Ambient Temp. (f+): Plastic Unit Wt. (pct): Result Specification 41/4 3 -5 5.2 3 -6 67 59 147.5 Sample Date: 01/19/10 Sample Time: 0731 Sampled By: Barry Cuble Weather Conditions: Parly sunny, light breeze Accumulative Yards: 20 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):5 Date Water Added After (gal): 0 Sample Location: East turn lane at INN of S curb, 5'W & No. ID E Placement Location: Pavement, eastbound turn lane off Tested Burns Street and Coppell Road; N & S (lbs) entry at southbound Coppell Road Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 01/20/10 01/26/10 7 111,250 3,940 2 1 2 6.00 28.27 01/20/10 02/02/10 14 1 3 6.00 28.27 01/20/10 02/16/10 28 1 4 6.00 28.27 01/20/10 02/16/10 28 Comments: Samples Made 13y: Terracon Services: Obtain samples of fresh concrete at the placement locationq perform required fie samples. Terracon Rep.: Barry Cuble Started: 0600 Reported To: Contractor: .IR.I Paving Report Distribution: (1) oily of coppcll Tx (1),IR.II'avhig 1.1 (1) Freese mid Nichols Inc Finished: 1100 Reviewed By: Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CRnunl. 5.21.417. He,.3 Page I of