Loading...
ST0702-LR100121CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 174.0072 Irerrocan Service Date: 01/06/10 8901 Carpenter Frwy. Report Date: 01/21/10 Revision 1 Dallas, TX 75247 214- 630 -1010 ReQ No: F -3272 Client Project City of Coppell TX Attn: Rick O'Dell Engineering Dept PO Box 9478 Coppell, TX 75019 Material Information Specified Strength: 3,600 psi @ 28 days Mix ID: 1707 Supplier: Lattimore Batch Time: 0755 Plant: 7 Truck No.: 3012 Ticket No.: 7213540 Field Test Data Test Slump (in): Air Content (' %,): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pct) Result Specification 3 1/4 3 -5 5.0 3 -6 50 40 146.2 Laboratory Test Data Coppell Road - #ST07 -02 Bethel Road to Southwestern Blvd. Coppell, TX Proiect Number: 94091174 Sample Information Sample Date: 01/06/10 Sample Time: 0831 Sampled By: Christopher P. Moran Weather Conditions: Overcast, windy Accumulative Yards: 30 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):5 Water Added After (gal): 0 Sample Location: Sta. 2 +90 Placement Location: Pavement fi•om Sta. 2 +50 to Sta. 16 +00 Set Specimen Diameter Area Date Date No. 1 D (in) (sq in) Received Tested 1 1 6.00 28.27 01/07/10 01/13/10 1 2 6.00 28.27 01/07/10 01/20/10 1 3 6.00 28.27 01 /07/10 02/03/10 1 4 6.00 28.27 01/07/10 02/03/10 Comments: Age at Maximum Compressive Test Load Strength Fracture (days) (lbs) (psi) Type 7 148,780 5,260 4 14 163,330 5,780 2 28 28 Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast compressive strength samples. Terracon Rep.: Christopher P. Moran Started: 0600 Reported To: Finished: 1600 Contractor: IRJ Paving Report Distribution: (1) City of Coppell TX (1) Freese and Nichols hic (I) JR1 P;rcinp LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ('10100. 5-2 1 .09. 11 1, Page I of 6 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 174.0072 Irerracon Service Date: 01/06/10 8901 Carpenter Frwy. Report Date: 01/21/10 Revision 1 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 3,600 psi ct 28 days Mix ID: 1707 Supplier: Lattimore Batch Time: 0838 Plant: 7 Truck No.: 9113 Ticket No.: 6364084 Field Test Data Test Slump (in): Air Content ( %,): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pct): Result Specification 5 3 -5 7.2 3 -6 49 40 142.4 Sample Date: 01/06/10 Sample Time: 0932 Sampled By: Christopher P. Moran Weather Conditions: Overcast, windy Accumulative Yards: 130 Batch Size (cy): 10 Placement Method: Direct - Discharge Water Added Before (gal): 10 Water Added After (gal): 0 Sample Location: Sta. 4 +00 Placement Location: Pavement from Sta. 2 +50 to Sta. 16 +00 Laboratory Test Data Set Specimen No. ID 2 1 2 2 2 3 2 4 mments: Diameter Area Date Date (in) (sq in) Received Tested 6.00 28.27 01 /07/ ] 0 01 /13/10 6.00 28.27 01/07/10 01/20/10 6.00 28.27 01 /07/ 10 02/03/10 6.00 28.27 O 1 /07/ 10 02/03/10 Age at Test (days) 7 14 28 28 Maximum Compressive Load S Strength Fracture (lbs) ( (psi) Type 126,540 4 4,480 2 147,930 5 5,230 2 .a Page 2 ot'G CONCRETE COMPRESSIVE STRENGTH TEST REPORT 1 111111111 Report Number: 94091 174.0072 [erracon Service Date: 01/06/10 8901 Carpenter Frwy. Report Date: 01/21/10 Revision 1 Dallas, TX 75247 214- 630 -10 10 Reg No:F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 3,600 psi @ 28 days Mix ID: 1707 Supplier: Lattimore Batch Time: 0930 Plant: 7 Truck No.: 1027 Ticket No.: 6364293 Field Test Data Test Slump (in): Air Content Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 4 3 -5 5.3 3 -6 49 40 145.5 Laboratory Test Data Set Specimen Diameter No. ID (in) 3 I 6.00 3 2 6.00 3 3 6.00 3 4 6.00 Sample Date: 01/06/10 Sample Time: 1012 Sampled By: Christopher P. Moran Weather Conditions: Overcast, windy Accumulative Yards: 280 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):0 Water Added After (gal): 0 Sample Location: Sta. 7 +50 Placement Location: Pavement from Sta. 2 +50 to Sta. 16 +00 Age at Area Date Date Test (sq in) Received Tested (days) 28.27 01/07/10 01/13/10 7 28.27 01/07/10 01 /20/10 14 28.27 01/07/10 02/03/10 28 28.27 01/07/10 02/03/10 28 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 153,470 5,430 4 163,100 5,770 2 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locationn4 perform requited field tests and cast compressive strength samples. Terracon Rep.: Christopher P. Moran Started: 0600 Reported To: Contractor: .IR.I Paving Report Distribution: (1) City of Coppell TX (1) JRJ Paving 1.1' (1) Freese and Nichols Inc Finished: 1600 Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests vgere performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CK0101. 9- 21 -119, eea.J Page 3 of 6 CONCRETE COMPRESSIVE STRENGTH TEST REPORT ME Report Number: 94091 174.0072 lerracon Service Date: 01/06/10 8901 Carpenter Frwy. Report Date: 01/21/10 Revision 1 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of coppel I 'rx Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppel I, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 3,600 psi @ 28 days Mix ID: 1707 Supplier: Lattimore Batch Time: 0958 Plant: 7 Truck No.: 1039 Ticket No.: 6364078 Field Test Data Test Slump (in): Air Content Concrete Temp. (P): Ambient Temp. (P): Plastic Unit Wt. (pct): Result Specification 4 1/2 3 -5 6.3 3 -6 50 40 143.5 Laboratory Test Data Set Specimen Diameter No. ID (in) 4 I 6.00 4 2 6.00 4 3 6.00 4 4 6.00 Sample Date: 01/06/10 Sample Time: 1042 Sampled By: Christopher P. Moran Weather Conditions: Overcast, windy Accumulative Yards: 350 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):0 Water Added After (gal): 0 Sample Location: Sta. 10 +00 Placement Location: Pavement from Sta. 2 +50 to Sta. 16 +00 Age at Area Date Date Test (sq in) Received Tested (days) 28.27 01 /07/10 01/13/10 7 28.27 01/07/10 01/20/10 14 28.27 01/07/10 02/03/10 28 28.27 01/07/10 02/03/10 28 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 133,450 4,720 4 145,650 5,150 2 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast compressive strength samples. Terracon Rep.: Christopher P. Moran Started: 0600 Reported To: Finished: 1600 Contractor: JR.1 Paving Report Distribution: (1) City of' CoppelI Tx (1) Freese mid Nichols tic (1),IR.I Paving LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172; ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CRAH , i t- N , te�•�. Page 4 of 6 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 174.0072 Verracon Service Date: 01/06/10 8901 Carpenter Frwy. Report Date: 01/21/10 Revision 1 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppel I TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 3,600 psi @ 28 days Mix ID: 1707 Supplier: Lattimore Batch Time: 1042 Plant: 7 Truck No.: 7059 Ticket No.: 6364107 Field Test Data Test Slump (in): Air Content Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pef): Result Specification 3374 3 -5 6.1 3 -6 50 41 144.5 Sample Date: 01/06/10 Sample Time: 1128 Sampled By: Christopher P. Moran Weather Conditions: Overcast, windy Accumulative Yards: 420 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):5 01/13/10 Water Added After (gal): 0 Sample Location: Sta. 12 +50 Placement Location: Pavement from Sta. 2 +50 to Sta. 16 +00 Laboratory Test Data Set Specimen No. I D Diameter Area Date Date (in) (sq in) Received Tested 6.00 28.27 01/07/10 01/13/10 6.00 28.27 01 /07/ 10 01/20/10 6.00 28.27 01 /07/ 10 02/03/10 6.00 28.27 01/07/10 02/03/10 Age at Test (days) 7 14 28 28 Maximum Compressive Load Strength Fracture (Ibs) (psi) Type 126,310 4,470 4 146,900 5,200 2 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Christopher P. Moran Started: 0600 Reported To: Finished: 1600 Contractor: .IRJ Paving Report Distribution: (I) City ul' Coppell 'I'x (I) Freese and Nichols Inc (I) JR.I Paying LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively forthe use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or Identical materials. cluuxn. 3•31.01 ,, lip, -.; Page 5 of G CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 174.0072 Ifierracon Service Date: 01/06/10 8901 Carpenter Frwy. Report Date: 01/21/10 Revision 1 Dallas, TX 75247 214 - 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 3,600 psi @ 28 days Mix ID: 1707 Supplier: Lattimore Batch Time: 1246 Truck No.: 7064 Field Test Data Test Slump (in): Air Content Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pef): Plant: 7 Ticket No.: 7213589 Result Specification 4 3 -5 5.3 3 -6 50 6.00 40 3 146.7 6 Laboratory Test Data Set Specimen Diameter No. ID (in) 6 1 6.00 6 2 6.00 6 3 6.00 6 4 6.00 Sample Date: 01/06/10 Sample Time: 1321 Sampled By: Christopher P. Moran Weather Conditions: Overcast, windy Accumulative Yards: 320 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):0 Water Added After (gal): 0 Sample Location: Sta. 14 +25 Placement Location: Pavement from Sta. 2 +50 to Sta. 16 +00 Age at Area Date Date Test (sq in) Received Tested (days) 28.27 01/07/10 01/13/10 7 28.27 01/07/10 01/20/10 14 28.27 01/07/10 02/03/10 28 28.27 01/07/10 02/03/10 28 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 166,100 5,880 4 182,200 6,440 2 Comments: Samples Made 13y: Terracon Services: Obtain samples of fresh concrete at the placement locationq perform required field tests and cast samples. Terracon Rep.: Christopher P. Moran Started: 0600 Reported To: Finished: 1600 Contractor: .IR.I Paving Report Distribution: (1) Cily or Coppell TX (1) Freese and Nichols Inc Reviewed By: (I)JR.I Paving IT Eric J Cleveland, P.E. Seniot Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for• the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. OWN) I. 5.21.M. Ilcr.i Page 6 of 6 CONCRETE COMPRESSIVE STRENGTH TEST REPORT 11101 IM Report Number: 94091 174.0078 'IffiVerracon Service Date: 01/13/10 8901 Carpenter Frwy. Report Date: 01/21/10 Dallas, TX 75247 214 - 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Ricl< O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi a 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: Truck No.: 9115 Field Test Data Plant: 07 Ticket No.: 7213807 Test Slump (in): Air Content ('%1): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 5172 3.8 55 40 Laboratory Test Data Set Specimen Diameter No. ID (in) 1 1 6.00 1 2 6.00 1 3 6.00 1 4 6.00 Sample Date: 01/13/10 Sample Time: Sampled By: John Halverson Weather Conditions: Clear Accumulative Yards: 10 Batch Size (cy): Placement Method: Direct Discharge Water Added Before (gal):0 Water Added After (gal): 0 Sample Location: North of railroad tracks Placement Location: Two inlets at northbound side of road Age at Area Date Date Test (sq in) Received Tested (days) 28.27 01/14/10 01/20/10 7 28.27 01/14/10 01/27/10 14 28.27 01/14/10 02/10/10 28 28.27 01/14/10 02/10/10 28 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 152,120 5,380 2 Comments: Not tested for plastic unit weight. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locationq perform required field tests and cast compressi strength samples. Terracon Rep.: Terry Smith Insp /Testing Started: 1400 Reported To: Finished: 1730 Contractor: JRJ Paving Report Distribution: (1) City or Coppell 'rx (1) Freese and Nichols Inc Reviewed By: (t).1R.11';iviaE Ll' Eric J. Cleveland, P.E. Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of-other apparently similar or identical materials. CWX)01. 5.21.00 (i , 3 Page 1 of I