Loading...
ST0701-LR100202CONCRETE COMPRESSIVE STRENGTH TEST REPORT I= HIM Report Number: 94091 193.0077 lFerracon Service Date: 01/25/10 8901 Carpenter Frwy. Report Date: 02/02/10 Dallas, TX 75247 214- 630 -1010 Reg No:F -3272 Client City of Coppel I TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Project Southwestern Boulevard Coppell Road to Grapevine Creek Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi n 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1 127 Plant: 6 Truck No.: 7025 Ticket No.: 6365113 Field Test Data Test Slump (in): Air Content (' %,): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 3 1/2 3 -5 4.3 3 -6 62 58 150.7 Laboratory Test Data Set Specimen Diameter No. ID (in) 1 1 6.00 1 2 6.00 1 3 6.00 1 4 6.00 Samples Made By: Terracon Sample Date: 01/25/10 Sample Time: 1247 Sampled By: Barry Cuble Weather Conditions: Sunny, breezy Accumulative Yards: 3.5 Batch Size (cy): 3.5 Placement Method: Direct Discharge Water Added Before (gal):8 Water Added After (gal): 0 Sample Location: See Placement Location Placement Location: Pavement, inlet strip at Sta. 3 +95 Age at Area Compressive Load S Test (sq in) (psi) Type 126,300 4 (days) 28.27 7 28.27 14 28.27 28 28.27 28 Date Received 01/26/10 01 /26/ 10 O 1 /26110 01/26/10 Date Tested 02/01/10 02/08/10 02/22/ 10 02/22/10 Maximum C Compressive Load S Strength Fracture (Ibs) ( (psi) Type 126,300 4 4,470 2 c Redly Associates LP Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cuuuni. s -v•uo, ucv.J Page I of I ' REINFORCING STEEL OBSERVATIONS REPORT "Irerracon Report Number: 94091193.0079 Service Date: 01/27/10 8901 Carpenter Frwy. Report Date: 02/02/10 Dallas, TX 75247 214 - 630 -1010 Reg No: F-3272 Client Project City of Coppell TX Southwestern Boulevard Attn: Kcith Marvin Coppell Road to Grapevine Creek PO Box 9475 Coppell, TX Coppell, TX 75019 Proiect Number: 94091193 PROJECT DATA Drawings Utilized: SL1.10 Locations /Items Observed: Bridge - Wing Walls at south side, east and west walls Test Method: Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Vapor Barrier Rebar Clean X Dowel Bars In Place X Welded Splices Trash & Debris Removed X Proper Bar Supports X Mechanical Splices Number of Bars X Proper Cover /Clearance X Lapped Splices X Discrepancies /Comments: No discrepancies were noted at the time of this observation. Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Barry Cuble Reported To: Contractor: Lacy Construction Report Distribution: (1) City of Coppell "I'x (1) City al'Cnppell'1'X (1) Lacy Umisirucliun (1) City of Coppell Tx (2) Flalff Assoc Inc Reviewed By: (1) PacTrust Pacific Really Associates LP The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of I Sa Senior Project Manager FIELD DENSITY TEST REPORT Report Number: 94091 193.0081 iierracon Service Date: 01/27/10 8901 Carpenter Frwy. Report Date: 02/02/10 Dallas, TX 75247 214 - 630 -1010 Reg No: -3272 Client Project City of Coppell TX Southwestern Boulevard Attn: Keitli Marvin Coppell Road to Grapevine Creek PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091193 Material Information Lab Test Data Project Requirements Optimum Max. Lab Water Dry Unit Water Minimum Mat. Proctor Laboratory Content Weight Content Compaction No. Rel'. No. Classification and Description Test Method ( %) (pcf) ( %) ( %) 1 94091 193.0002 Dark brown clay, with sand ASTM D698 24.2 94.6 0/ +4 95 Field Test Data Probe Wet Water Water Dry Unit Percent Test Lift / Mat. Depth Density Content Content Weight Compaction No. Test Location Elev. No. (in) (pef) (pcf) ( %) (pcf) ( %) 8" Seger, B -1 34 Sta. 12 +88 Final 1 6 119.6 25.4 27.0 94.2 100 Gauge ID: 1960 Comments: Test results on this report meet project requirements as noted above. Services: Perform in -place density and moisture content tests to determine degree of compaction and malr'• condition. Terracon Rep.: Barry Cuble Reported To: Oscar, Lacy Construction Contractor: Lacy Construction Report Distribution: (1) City of Coppell •I'x (1) City of Coppell TX Reviewed By: (1) City ol'Coppcll '1'x (2) linlff Assoc Inc iIC J. (1) Lacy C'onsuvctian (1) PacTntst Pncific Renhy Associates LP Senior Test Methods: ASTM D6938 moisture ect Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. C'Itniwq..t- :a.iw. Rt 1%2 Page I of I