ST0701-LR100122FIELD DENSITY TEST REPORT Report Number: 94091 194.0024 Irerracan Service Date: 01/11/10 8901 Carpenter Frwy. Report Date: 01/22/10 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client PaCTRISt Pacific Realty Associates LP Attn: Matthew Oyen 15350 Southwest Sequoia Pkwy Ste 300 Portland, OR 97224 Project Southwestern Boulevard Grapevine Creek to Beltline Road Coppell, TX Project Number: 94091194 Material Information Mat. Proctor No. Ref. No. 1 9409.1 193.00.55 Field Test Data Classification and Description Dark gray clay (lime treated) Test No. Test Location Laboratory Test Method ASTM D698 Probe Wet Lift / Mat. Depth Density Elev. No. (in) (pcf) Lab Test Data Project Requirements Optimum Max. Lab Water Dry Unit Water Minimum Content Weight Content Compaction ( % ) (pcf) ( %) ( %) 38.2 79.1 -2/ +4 95 Water Water Dry Unit Percent Content Content Weight Compaction (Pc') ( %) (pef) ( %) Paving, Southwestern Blvd., Eastbound 31 Sta. 8+00 FG 1 6 106.4 28.6 36.8 77.8 98 32 Sta. 10 +00 FG 1 6 108.3 29.8 38.0 78.5 99 33 Sta. 12 +00 FG 1 6 108.9 29.5 37.1 79.4 100 Datum: FG = final grade Gauge ID: 39547 Comments: Test results on this report meet project requirements as noted above. Services: Perform in -place density and moisture content tests to determine degree of compaction and mat;rial moisture condition. Terracon Rep.: Francisco J. Morillo Reported To: Superintendent Contractor: Lacy Construction Report Distribution: (1) PacTrust Pacific Realty Associates LP (1) City of Coppell TX Reviewed By: z 0 (1) City of' Coppcu TX (2) HnlrrAssoc Inc Eric J. Cleveland, P.E. (1) Lacy Consauction Senior Project Manager Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cn0007, 4 -30-0 it-.2 Page 1 of I CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 193.0067 1 lel I cJLun Service Date: 01/14/10 8901 Carpenter Frwy. Report Date: 01/22/10 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Southwestern Boulevard Attn: Keith Marvin Coppell Road to Grapevine Creek PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Sample Date: 01/14/10 Sample Time: 0955 Sampled By: Christopher P. Moran Mix ID: DCSOHSO4 Weather Conditions: Overcast, light breeze Supplier: Redi -Mix Accumulative Yards: 10 Batch Size (cy): 10 Batch Time: 0916 Plant: 136 Placement Method: Pump Truck No.: 1 192 Ticket No.: 25154810 Water Added Before (gal): 15 Water Added After (gal): 0 Field Test Data Sample Location: Sta. 13 +85 Test Result Specification Placement Location: Bridge Deck, east Bound, Sta. 13 +56 to Slump (in): 5 3 -5 Sta. 14 +05 Air Content (' %o): 6.0 3 -6 Concrete Temp. (F): 57 Ambient Temp. (F): 50 Plastic Unit Wt. (pcf): 146.1 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 01/15/10 01/18/10 4 110,400 3,910 4 1 2 6.00 28.27 01115110 01/21/10 7 136,420 4,830 2 1 3 6.00 28.27 01115110 01/28/10 14 1 4 6.00 28.27 01/15/10 02/11/10 28 1 5 6.00 28.27 01/15/10 02/11/10 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement location4 perform required field tests and cast compressive strength samples. Terracon Rep.: Christopher P. Moran Started: 0900 Reported To: Finished: 1430 Contractor: Lacy Construction Report Distribution: (1) City of Coppell TX (1) City of Coppell TX Reviewed By: (I) City of Coppell Tx (2) Halff Assoc Inc Eric F Clev land, P.E. (I) Lncy Constriction (1) PncTnist Pncific Renity Associates LP Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cltutwl. 5.21.0 Re'3 Page I of REINFORCING STEEL OBSERVATIONS REPORT Irerracon Report Number: 94091193.0069 Service Date: 01 /20/10 8901 Carpenter Frwy. Report Date: 01/22/10 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Southwestern Boulevard Attn: Keith Marvin Coppell Road to Grapevine Creek PO Box 9478 Coppell, TX Coppell, TX 75019 Proiect Number: 94091193 PROJECT DATA Drawings Utilized: SC1.2 Locations /Items Observed: Bridge Deck, East Bound, Sta. 14.02 to Sta. 14 +47 Test Method: Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars In Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover /Clearance X Discrepancies /Comments: No discrepancies were noted at the time of this observation. Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Christopher P. Moran Reported To: Teroy Contractor: Lacy Construction Report Distribution: (1) City of Coppell Tx (1) City of Coppell TX (1) City o r Coppel l 'f N (2) Ha l ff Assoc Inc (1) Lacy C onslructiun (1) PacTrusl Pacific Realty Associates LP Reviewed By: Eric J. C veland, P.E. Senior P /Oject Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of I Sa CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 194.0016 Irerracan Service Date: 01/15110 8901 Carpenter Frwy. Report Date: 01/22/10 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project PacTfUSt Pacific Realty Associates LP Southwestern Boulevard Attn: Matthew Oyen Grapevine Creek to Beltline Road 15350 Southwest Sequoia Pkwy Ste 300 Coppell, TX Portland, OR 97224 Project Number: 94091194 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1439 Plant: 7 Truck No.: 1076 Ticket No.: 7213881 Field Test Data Test Slump (in): Air Content (' %o): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pct) Result Specification 2 1/2 3.6 60 54 148.7 Laboratory Test Data Sample Date: 01115110 Sample Time: 1523 Sampled By: Barry Cuble Weather Conditions: Cloudy, light breeze Accumulative Yards: 7 Batch Size (cy): 7 Placement Method: Direct Discharge Water Added Before (gal):5 6.00 Water Added After (gal): 0 Sample Location: See Placement Location Placement Location: Inlet Walls and Bottom at B /l, Sta. 01/16/10 1 +04; B /3, Sta. 0 +74 Set Specimen Diameter Area Date Date No. ID (in) (sq in) Received Tested 1 1 6.00 28.27 01/16/10 01/22/10 1 2 6.00 28.27 01/16/10 01/29/10 1 3 6.00 28.27 01 /16 /10 02/12/10 1 4 6.00 28.27 01/16/10 02/12/10 Age at Maximum Compressive Test Load Strength Fracture (days) (lbs) (psi) Type 7 170,260 6,020 2 14 28 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast c repressive strength samples. Terracon Rep.: Barry Cuble Started: 1500 Reported To: Finished: 1730 Contractor: Lacy Construction Report Distribution: Reviewed By: (1) PacTrusl Neilic Really Associates LP (1) City of Coppell TX (1) City of Coppell 'I'X (2) Halff Assoc Inc IC . CI eV and, P.E. (1) LacyConxunctiini Senior Projett Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of I f'RINw 1. i-2 1-00. Rcr.