Loading...
Rolling Oaks MC-CS081028Page 1 of 1 Michael Garza - Rolling Oaks Memorial Center: COR 003 /Gas Line Extension From: "Ken Baxter" <kbaxter( ',j starchitects.com> To: "Alex Fisher" <AFisher(�'.Haingp.com> Date: 10/28/2008 12:23 PM Subject: Rolling Oaks Memorial Center: COR 003 /Gas Line Extension CC: <rodellgci.coppell.tx.us >, "Brad Reid" <BREIDgci.coppell.tx.us >, "Michael Garza" <mgarzagci.coppell.tx.us >, <jwbrowngstei.com >, <lfsloanegaol.com> Attachments: Response to COR 03.docpdf.pdf; COR 003.pdf; Rolling Oaks Memorial Center.pdf; ROLLING OAKS PROPOSED.pdf; a Gas Contract, Work Assignment Supplement DEV SWPPP offsite SAMPLE.DOC; CROSSING SLEEVE SPECS.pdf; Meter_Spec_Manual_05 -05 .pdf Alex, Attached is our response to COR 003. Thanks, Ken Baxter Senior Project Manager J. Stuart Todd, Inc. Architecture/Interiors /Planning 2919 Welborn Dallas, Texas 75219 214 -522 -4033 214 -522- 7988 fx. file: HC: ADocuments and Settings \radloo \Local Settings\ Temp \XPgrpwise \4907044CCity_of... 4/5/2010 I Stuart Todd ine. 2919 Welborn, Suite 101 Dallas, Texas 75219 ,214) 5224033 Fax: (214) 522-7988 To: The Fain Group Date: 10/28/08 IJob No 04751 Attn: Alex Fisher Re: Rolling Oaks Memorial Center: COR 03 rRANSMIrTED VL4:lst Class Mail —Federal Express -- Delivery_Yax�_ X CONSTRUCTION MEMO: Alex, We have reviewed the Change Order Request 03 regarding the natural gas mainline extension required for We understand that in order to gas mainline extension as prow execute the "Work Assignmen M subcontractor Fain will paperwork and necessary pay requests until final acceptance has been processed by Atmos Energy Corp., This is to be undertaken with an understanding that the City of Coppell is the ultimate party responsible to provide and finalize the required "easement" and "right of way" platting documentation along with the "Form of Bill of Sale and Assignment" and "Form of Easement" Agreements and any other executed agreements or documentation as may be required by Atmos Energy Cor►.. in order for the work to be completed, approved and finalized. We will issue this within the next Change Order Document for the Owner's final review and processing. Please call if you have any questions, Cc: Mike Garza/COP Rick 0"Del]YCOP JST file TITLE: Gas Main Service to Rolling Oaks Site PCO Item: 3 Rolling Oaks Memorial Center Coppell, TX Labor Labor Additional FAIN Labor Items: Crew Unit Hours Rate Cost Ea 0 $ - $ Subtotal FAIN Labor: $ - Burder @ 55 %: $ - Total FAIN Labor. $ - Additional FAIN Material Items: Quantity Unit Unit Cost Material Cost Total Material: $ - ji Additional FAIN Equipment: Quantity Unit Hours Equipment Unit Equipment Cost Subtotal FAIL Equipment: $ - Fuel, Oil & Grease: $ Total FAIN Equipment $ Additional Subcontractor Items: Quantities Unit Unit Price Total. Murray Construction (contractor running gas service) LS $ 11,500.00 $ 11,500.00 Brack Environmental (SWPPP) LS $ 1,200.00 $ 1,200.00 LS $ - $ Total Subcontractor Items: $ 12,700.00 Summary of Costs Total FAIN Items: $ 10% Overhead $ Subtotal $ 5% Profit $ Subtotal $ - Subcontractor Unit Price: $ 12,700.00 10% Overhead on Sub Items $ 120.00 Subtotal $ 12,820.00 Bond - 1.18% $ 151.28 UNIT PRICE hp 12,971.28 QUOTE - Gas Infrastructure DATE: 09/22/08 TO: Alex Fisher The Fain Group Location: Rolling Oaks Memorial Center Coppell,TX ITEM/DESCRIPTION QTY UNIT UNIT PRICE TOTAL ESTIMATE Install Atmos infrastructure in project : 1 lots $ 11,500.00 $ 11,500.00 includes all labor, material,sandbackfill and equipment to required to install per Atmos design dated : 09 -05- 08 - (950) I.f.2" poly by open cut along Ruby Rd. - (40) I.f. 2" by directional bore along Ruby Rd beside the existing fence - install 1 - 1 1/4" SL Riser w/ stop & plug - testing,bends,tees,test stations, caps, collars,signs,tracer wire,and marker tape TOTAL 1 $ 11,500.00 NOTES: We will require 4 working days to complete the gas infrastructure. We will bill for the entire amount of the above quote upon completion of work, since Atmos accepts responsibility for the new infrastructure it is assumed that no retainage will be held from this billing . 515 N. KEALY LEWIS\ALLE. TX 75057 (972) 436 -4566 PHONE (972) 219-0019 Fax It is assumed that staking and density testing, if required, will be paid by others and any spoils will be placed on site. ( Quote Good for 30 days ) Signature 9/22/2008 Date IMM.,nii C � PROJECT SUMMARY: INSTALL APPROXIMATELY 940 FEET OF 2 INCH POLY MAIN AND ONE 1 1/4 INCH POLY SERVICE LINE AND THREADED RISER AS SHOWN 301 rRLR 25 DEVELOPER IS RESPONSIBLE FOR \ 3 +97 SVC -TAP 6 12 +91 svc - rA@ - G Q H U a Fa' U V N p , GAS MAIN ROUTES AND SERVICE + Pl-xlx>q t z, awh ABAND T R30 RR 550 TR — �p , , PI',10 +15 CB & TL -10 +19 `y 550 TRLRI — 10 +i2 L�t R 550 TRLR 3 I 0+90 XX +XX SVC - TAF& - ' X1 550 TRLRi3 13 +6 540T — > 1 +50 650 TRLF 550 TRLR ��,. ._ �— DEVELOPER IS RESPONSIBLE FOR SURVEYING /STAKING ALL EASEMENTS, ROW'S 12 +91 svc - rA@ - p , GAS MAIN ROUTES AND SERVICE 550 TRL9 4( LINE LOCATIONS INCLUDING ANY SWPPP — �p , , REQUIREMENTS PRIOR TO CONSTRUCTION. R I � 13 +6 540T — > 550 TRLR -- PARKING AR F - _ 10 550 TRLR kMORTUaARYe 102 14 +38 SVC -TAFO— I J Q J CGWMBNRIUM 5 50 TRLIR 550 T RLR ,A I'/ � ° 14 +7 CTAW -`- 550 TRLR' - ---------- - -- -- ---------------- +fi + DE - & CBS 5 +65 ON POND PRpPOSE° — TRUCK C A� 550 264 � 4 +44 Legend ola nn [�aa_malrn,mmnl Main. Existing HIM Pressure Roele Main.Existing Intertnetliate Pressure Route Maln. Existing Low Pressure Route - -- V., -posed lnl —dlate Pressure R-t. d Metn PUa Annotalion Annotation <I Main Olfsel Texl.Annolalion A J Main OHse Symh =I Main Protect Nai ie Ani� Main Small AnnolallonAnaOlallon �rvmaTCa._ unl a�X TaPAaa� 5 - .E tmg Low P ule —s oo Peaeem Rume O Id P E' g OAnnotanonc [Gec_ais libmion7 at o, m Al . <r Gas NoteAnnolalior. u�o.r Oes Note COnstraction Annotation E XSsTS GAS CONSTRUCTION PRINT PRa1E1NO NR NA PROJ ECT Hay,. Run — — 8 WORK ASSIGNMENT SUPPLEMENT This Work Assignment Supplement is entered into effective , 200_, by and between ( "CONTRACTOR'"), ( "DEVELOPER"), and Atmos Energy Corporation ( "COMPANY "). PERFORMANCE OF WORK - CONTRACTOR will perform the work identified herein (the "Work ") as authorized by COMPANY, pursuant to the terms and conditions in the Assigned Task Agreement between COMPANY and CONTRACTOR, which Agreement is incorporated herein by reference. When and as expressly authorized by COMPANY, and notwithstanding any provision to the contrary in the above- referenced Assigned Task Agreement, DEVELOPER will, without contribution from or obligation on the part of COMPANY, pay CONTRACTOR the full and complete cost of the Work, as mutually agreed between CONTRACTOR and DEVELOPER. SCOPE OF WORK - CONTRACTOR will perform the Work in accordance with the Scope of Work Attachment and the drawings, specifications, and instructions, if any attached hereto, and identified in the List of Attachments „fit forth herein. DEVELOPER will have the right, at all times, to instruct CONTRACTOR to constrict the Work in a use with the Scope of Work Attachment, but DEVELOPER has no obligation to supervise CONTRACTOR n th ance of the Work, � CONTRACTOR will, in consultation with DEVELOPER, assume full responsibility for inv tigati "conditions of any property or facilities at or with respect to which Work will be performed, for the purpose of e' at ug and determining the existence and magnitude of any hazards resulting from such Work to such property, or to the r of DEVELOPER, or to the property or physical well-being of any of DEVELOPER's employees or a a CONTRACTOR and /or DEVELOPER, as appropriate, will ensure that DEVELOPER's and CONTRACTOR,' emp %ees and agents are advised of and fully understand the nature of such hazards and safety precautions that can be t iuninate or minimize the dangers relating to such hazards. ACCEPTANCE OF WORK - Upon inspection and acceptance by A 's inspector of the Work ( "Final Acceptance "), DEVELOPER will execute and deliver to COMPANY a Bil of and Assignment substantially in the form attached hereto and made a part hereof, conveying the Work to COMP A n addition, if the Work is not located under public rights -of -way or defined public utility easement, DEVELOPE "NN ll -rant to COMPANY an easement over the Work, which easement will be substantially in the form of the easement a ireto and made apart hereof It is understood and agreed that the transfer of the Work installed pursuant to this m i , and the granting of any easements to COMPANY hereunder, will be at no cost to COMPANY whatsoever. DEVELOPER must notify COMPANY's Project Manager " " least five days prior to commencement of constriction. CONTRACTOR must return all required field const uctt i ocimnents to Atmos Energy including, but not limited to, as- built, test charts and print line data within 10 worlin - f completion. INVOICES — All invoices will be sent to DEVLOR at the following address: Address: LIST OF ATTACHMENTS — attachments, if any, are incorporat 1. Scope of Work Attachtne 2. Design Layout of F �11 CONTRACTOR: By Name: Title: DEVELOPER: By Name: Title: DEVELOPER, and CONTRACTOR agree that the following described in their entirety. Form of Bill of Sale and Assignment Form of Easement ATMOS ENERGY CORPORATION Name: Title: WORK ASSIGNMENT SUPPLEMENT SCOPE OF WORK ATTACHMENT PROJECT # PROJECT NAME OR SUBDIVISION & PHASE: NUMBER OF METERS: DEVELOPER REQUIREMENTS: GAS MAIN EXTENSION CSWPPP, DEVELOPER/CONTRACTOR will develop and an and will also submit NOI for the off -site project on behalf R/CONTRACTOR will provide necessary sediment control etc. for installation and restabilization of the off -site project specified responsible for providing gas mains of the mnnber, dimensions, and footages COMPANY will be responsible for the following: L Inspecting all work performed by CONTRACTOR in a reasonably timely manner. 2. Notifying DEVELOPER within a reasonable time after Final Acceptance of the Work by COMPANY. 3. Installing service lines and risers for front lot distribution from service stubs in accordance with Atmos Energy's Meter Specification Manual (available at Atmosenergy.com). WORK ASSIGNMENT SUPPLEMENT DESIGN LAYOUT OF FACILITIES SEE PREVIOUSLY PROVIDED DESIGN WORK ASSIGNMENT SUPPLEMENT FORM OF BILL OF SALE AND ASSIGNMENT STATE OF TEXAS COUNTY OF KNOW ALL MEN BY THESE PRESENTS: THAT for good and valuable consideration, the receipt and sufficiency of which is hereby acknowledged, a corporation (hereinafter referred to as "Seller "), hereby grants, bargains, sells, assigns, transfers, and conveys into Atmos Energy Corporation, 5420 LBJ Frwy, Suite 1800, Dallas, Texas 75240, a Texas and Virginia corporation (hereinafter referred to as `Buyer "), its successors and assigns, all of Seller's right, title, and interest to and in the following, all of which is collectively referred to hereafter as the "Property": (a) that equipment and those facilities described in Attachment "1," located on that p described, configured and sittiated along the route described in Attachment - 2, - all such attachments bein;cr reof. and (b) all easements and permits related to the equipment and facilities set forth above, as° d in Attachment `4," being a part hereof 1 , Seller warrants that it is the lawful owner in every respect of the Property, and that t ie ipeline is free and clear of all liens, security agreements, encumbrances, claims, demands, and charges of eve . iii - hatsoever. Seller fiuther warrants that it is not aware of any existing violations of any law, ordinance, or regtala on r ng to the Property, or of any latent or patent defects in the Property. TO HAVE AND TO HOLD into the said Buyer, its successors and a ever, to warrant and defend the title to the Property against every person whomsoever lawfiilly claiming the Prop r ai y' part of it. Seller fiuther agrees to execute and deliver any and all fiuther co %e r nces, assignments, bills of sale, certificates, instruments of transfer, or other documents that may be necessary or yropriate to effectuate the terms hereof, and the terms of that certain Work Assignment Supplement between Buyer, Sell dated and to vest in Buyer, its heirs, representatives, successors, and assigns, title toA ro erty. IN WITNESS WHEREOF, this Bill of Sale and A ign it is executed on the _ day of 200. Atmos Energy Corporation By By Title: Title: Title: Pipe Installati ®n etas ®d: 1 ®11 Date; June 1, 2006 Page 7 ®f 12 FJ Meter Specification Manual :THOS energy Mid -Tex Division Dated: May 5, 2005 Meter Specification Manual This Meter Specification Manual is to instruct builders, plumbers and other contractors of the installation requirements for natural gas meters and service lines in the Atmos Energy, Mid -Tex Division service territory. These specifications are provided as a courtesy by Atmos Energy to facilitate installations by qualified and licensed contractors. Atmos Energy reserves the right to amend or modify these specifications from time to time. While Atmos Energy will use reasonable efforts to post any revisions hereto upon its website as soon as practicable, the installation contractor retains the obligation to contact Atmos Energy prior to performing any installation to insure proper use of the latest version of the specifications. Please refer back to the Atmos Energy web site at www.atmosenergy.com /txbuilder occasionally to check for updates to this document. Atmos Energy reserves the right to refuse service to any installation which does not comply with these specifications and /or any amendments or modifications hereto. For questions referring to information or illustrations in this document, please call your local Atmos Energy field construction coordinator or the New Construction Support Center at 866 -332 -8667 (toll free). Table of Contents Mid -Tex County Listings Page 3 Meter Location and Clearances Page 4 Above Ground Clearances Page 5 Meter Location With Respect to Main and Service Page 6 Page 2 Atmos Energy, Mid -Tex Division County Listing This Meter Specification Manual is applicable only in the following Texas counties. If your project is not in one of these counties, please contact your local Atmos Energy representative. Anderson, Archer, Bandera, Baylor, Bell, Bosque, Brazos, Brown, Burleson, Burnett, Callahan, Childress, Clay, Coke, Coleman, Collin, Collingsworth, Comanche, Concho, Cooke, Coryell, Cottle, Dallas, Delta, Denton, Eastland, Ellis, Erath, Falls, Fannin, Fisher, Foard, Franklin, Freestone, Gillespie, Grayson, Gregg, Hall, Hamilton, Hardeman, Harrison, Haskell, Henderson, Hill, Hood, Hopkins, Houston, Hunt, Johnson, Jones, Kaufman, Kendall, Kerr, Knox, Lamar, Lampasas, Lee, Leon, Limestone, Llano, Madison, Mclennan, Milam, Mills, Mitchell, Montague, Navarro, Nolan, Palo Pinto, Panola, Parker, Rains, Red River, Robertson, Rockwall, Runnels, San Saba, Scurry, Shackelford, Smith, Somervell, Stephens, Sutton, Tarrant, Taylor, Throckmorton, Tom Green, Travis, Van Zandt, Wichita, Wilbarger, Williamson, Wise, Wood, Young Page 3 AT THE BUILDING (SEE NOTE 6) 8" MIN. P/L P/L 4' TO 6' TYPICAL ELEVATION NOTES: 1. ABOVE GROUND GAS PIPING (METER, RISER, ETC.) MAY NOT BE PLACED WITHIN 36 INCHES HORIZONTAL MEASUREMENT OF: A. AN ELECTRICAL METER OR OTHER ELECTRICAL EQUIPMENT (INCLUDING TRANSFORMER). B. COMBUSTION OR FRESH AIR INTAKE. C. ANY IGNITION SOURCE. C 2. IF THE ABOVE GROUND LOCATION IS VULNERABLE TO VEHICULAR TRAFFIC, CONSIDER INSTALLING A BARRIER. SEE STD. DWG. 10- 002 -00. 3. WITHOUT PRIOR APPROVAL FROM ATMOS ENERGY MID -TEX DIVISION STANDARDS, NO PART OF METER ASSEMBLY MAY BE PLACED UNDER: A. A WINDOW THAT OPENS. B. A FIRE ESCAPE. C. A CARPORT ROOF, AWNING OR ENCLOSURE OTHER THAN A STANDARD EAVE. D. CABLE TV /TELEPHONE EQUIPMENT ENCLOSURES. 4. GREATER CLEARANCE MAY BE REQUIRED BY LOCAL ORDINANCE OR MANUFACTURER'S SPECIFICATIONS. 5. SEE ALSO STD DWG. 10- 005 -00 & 10- 006 -00. SIDE VIEW 6. IF GAS METER IS 5 FEET OR MORE FROM WALL, THEN HORIZONTAL AND VERTICAL DIMENSIONS SHOWN IN ELEVATION ARE NOT APPLICABLE DESIGNED BY: M. KOLKMEIER DRAWN BY: B. BORCOMAN CHECKED BY: P. TUCKER APPROVED APPROVED BY: APPROVED BY: APPROVED BY: P. TUCKER M"k 5/15/02 METER LOCATION 4/18/05 AND CLEARANCES WITH RESPECT 4/20/05 TO BUILDING FEATURES ENGR. ENGINEERING STANDARD MEAS. A.I.N. DSWR #: STDS. 4/22/05 DWG. NO. STD. 10-004-00 ISHT. STD. 950 -01 -00 4/22/05 PLACES DRAWING DATE TMOS energy 60" MIN. GROUND TRANSFORMER CLEARANCE DETAILS LEFT SIDE GAS METER OPTION ELEVATION BACK SIDE GAS METER OPTION 45" MIN. 60" MIN. TRANSFORMER DO NOT INSTALL GAS METER IN FRONT OF A TRANSFORMER LEFT SIDE GAS METER OPTION PLAN IR" AAIN 1R" AAIN 42" MIN. RIGHT SIDE GAS METER OPTION 42" MIN. RIGHT SIDE GAS METER OPTION Lrri aiur MUM aiur ELEVATION GAS METER OPTION GAS METER OPTION PEDESTAL CLEARANCE DETAILS BACKSIDE GAS METER OPTION LEFT SIDE GAS METER OPTION 1 MIN. 18" MIN. RIGHT SIDE GAS METER OPTION 36" MIN. 21" MIN. _ FRONT SIDE GAS METER OPTION NOTES: 1. MEASUREMENTS ARE REFERENCED FROM THE INLET GAS RISER. PLAN 2. THE MEASUREMENTS WILL ENSURE: A. THAT A MINIMUM CLEARANCE OF 36 INCHES IS ATTAINED BETWEEN THE ENTIRE GAS METER INSTALLATION AND THE TRANSFORMER AND B. THAT A MINIMUM CLEARANCE OF 12 INCHES IS ATTAINED BETWEEN THE ENTIRE GAS METER INSTALLATION AND ALL OTHER ABOVEGROUND FACILITIES INCLUDING ELECTRIC AND OTHER UTILITY PEDESTALS AND HANDHOLES. 3. THIS STANDARD APPLIES TO 630 GAS METER INSTALLATIONS AND SMALLER. FOR LARGER METER INSTALLATIONS, CONTACT ATMOS ENERGY MID -TEX DIVISION STANDARDS FOR ASSISTANCE. 4. THIS DRAWING IS TYPICALLY USED WHEN THE GAS MAIN IS LOCATED IN AN ALLEY OR DEDICATED UTILITY EASEMENT. 5. IF THE ABOVE GROUND LOCATION IS VULNERABLE TO VEHICULAR TRAFFIC, CONSIDER INSTALLING A BARRIER. SEE STD. DWG. 10- 002 -00. DESIGNED BY: E.OSTROVICH DRAWN BY: B. BORCOMAN CHECKED BY: P. TUCKER 8/8/02 4/19/05 ABOVEGROUND CLEARANCES 4/20/05 OF GAS METER INSTALLATIONS APPROVED APPROVED BY: ENGR. ENGINEERING STANDARD APPROVED BY: MEAS. A.I.N. DSWR #: APPROVED BY: P. TUCKER STDS. 4/22/05 DWG. NO. STD. 10-006-00 SHT. STD. 950 -05 -00 I4I22I0 REPLACES DRAWING1 DATE Z mos energy Page 5 i i i i I. MAIN IN STREET: STREET (A) METER SHOULD BE SET AT FRONT OF BUILDING -- - - - - --0 OR WITHIN 15 FEET OF FRONT. q❑ (B) IF BUILDING IS 100 FEET OF MORE FROM 15' MAXIMUM PROPERTY LINE, METER SHOULD BE SET WITHIN LW 1 1/2 FEET OF PROPERTY LINE. F— - -------- --0 U) ' SEE NOTE 1 & 3 100' OR MORE _ ----------- ------------ - - - - - '- 1 -1/2' M AXIMUM Eil L II. MAIN IN ALLEY OF DEDICATED STREET UTILITY EASEMENT: F- z LU (A) METER SHOULD BE SET WITHIN 1 1/2 FEET OF -� ___________________ ❑ A w 1 -1/2' MAXIMUM F PROPERTY LINE OR EASEMENT BOUNDARY LINE. 0 w ' } in w LIJ SEE NOTE 1, 2 & 3. J Q U Lu in i L i III. MAIN IN SPECIAL EASEMENT: STREET ((A) METER SHOULD BE SET AS CLOSE AS W PRACTICAL TO MAIN. z ; --------------- - - - - -- W J Q w ; U) SEE NOTE 1, 2 & 3. �Q w NOTES: 1. SEE ALSO STD. DWGS 10- 004 -00 AND 10- 006 -00. 2. IF THE ABOVE GROUND LOCATION IS VULNERABLE TO VEHICULAR TRAFFIC, CONSIDER INSTALLING A BARRIER. SEE STD. DWG. 10- 002 -00. 3. THE METER INSTALLATION MUST HAVE A MINIMUM CLEARANCE OF 36 INCHES FROM PAD MOUNTED TRANSFORMERS AND 12 INCHES FROM OTHER ABOVEGROUND ELECTRICAL FACILITIES INCLUDING PEDESTALS (STD. 10- 006 -00). STD. 950 -02 -01 4I22I05 REPLACES DRAWING DATE DESIGNED BY: M. KOLKMEIER 11/06/02 METER LOCATION WITH RESPECT TO MAIN AND SERVICE LINE -TMOS DRAWN BY: B. BORCOMAN 4/18/05 CHECKED BY: P. TUCKER 4/20/05 APPROVED iIR energy ENGINEERING STANDARD APPROVED BY: ENGR. A.I.N. DSWR #: APPROVED BY: MEAS. APPROVED BY: P. TUCKER I STDS. 1 4/22/051 DWG. No. STD. 10-005-00 SHT.