Loading...
Duke Lesley 3A-LR1003298908 Ambassador Row, Dallas, TX 75247 Ro n e Engineering 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Com pressive Strength Test Client: Duke Construction, LP Report No.: 368622 14241 Dallas Pkwy, Ste 1000 Project No.: 0915747 Dallas, TX 75254 -2936 Date of Service: 02/27/2010 Report Date: 03/29/2010 Project: Samsung -Point West VII Parking Lot Expansion Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive samp s and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: LMC Plant: 7 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air ( %): 5% maximum Test Method: ASTM C -172 Batch time: 06:32am ASTM C -31 (except 10.1.2) Temperature - Air: ASTM C -143 Concrete: 45 °F ASTM C -231 Truck No: ASTM C -1064 Ticket No: 7214917 ASTM C -138 Air Content: ASTM C -39 Mix Design I.D.: 1621 Vi' Measured Placement Date: 02/27/2010 Compressive Slump Weather Conditions: Clear Age (inches) Time Sampled: 07:10am Batch time: 06:32am 4.0 Temperature - Air: 32 °F Concrete: 45 °F (in) Truck No: 9150 Ticket No: 7214917 Type Air Content: 5.5% Unit Weight (pcf): NA 5.99 Overall Placement Location: 130,560 4,630 1. Approach at middle of east side of building. 2. Northeast entrance paving to existing slab of paving. (cont below) Sample Location: Approach, southeast corner (curb), 2' north, 1' west REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (lbs) (psi) Type 1 1 03/06/2010 7 5.99 28.18 130,560 4,630 Type 2 1 2 03/27/2010 28 6.00 28.27 163,440 5,780 Type 2 1 3 03/27/2010 28 6.00 28.27 154,420 Type 5 Average 0 1 4 04/24/2010 56 [ILI <11 X I L' I �' -1112 - F1 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /NF) Page 1 of 2 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: Duke Construction, LP Report No.: 368622 14241 Dallas Pkwy, Ste 1000 Project No.: 0915747 Dallas, TX 75254 -2936 Date of Service: 02/27/2010 Report Date: 03/29/2010 Project: Samsung -Point West VII Parking Lot Expansion Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Cont: 3. Northeast entrance curb on right side. Results to superintendent. I PA Technician: Henry Nichols Started: 06:15am Finished: 08:30am Rone Engineering Report Distribution: Ong: Duke Construction, LP (Dallas, TX) - -_ - - -- Attn: Ms. Ashley Hair (1 -ec copy) 1 -ec Duke Construction, LP Attn: Mr. Andy (Maverick) Otten 1 -ec Rone Project Manager Attn: Mr. K. Scott Watson AET K. Scott Watson, AET 1 -ec City of Coppell Attn: Mr. Lee Stone Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /NF) Page 2 of 2