Loading...
Rolling Oaks MC-LR081105CTLITHOMPSON CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 Date: 1110512008 Report ID: K61992 - DA08152.000 Report of Concrete Compressive Strength Tests Project: ROLLING OAKS MEMORIAL CENTER PHASE I Supplier: TXI INDUSTRIES FREEPORT PARKWAY Location: PAVING, 120' SE OF THE NORTH FIRE HYDRANT Cast Date: 1012412008 Ticket: 775493 Batch Time: 15:53 Concrete Mix: 8274 In -Lab Date: 1012512008 Truck Number: 8001 Test Time: 17:20 Specimens Made By: BB Initial Curing Final Curing Curing Method: Min. Temp: Max Temp: Curing Method: Other ° F ° F Fog Room Physical Properties of Concrete (ASTM C143, C231, C138, C1064) Specified Strength (fc) Slump Air Content Density Temperature 3600 psi @ 28 days 5.25 in. 3.1% 84 deg. F Compressive Strengths (ASTM C39) Specimen Age in Number Days 1 1 7 2 1 7 Diameter (inches) Area (sq. inches) 4.00 12.57 4.00 12.57 Max. Load Compressive Percent Type of (Ibs.) Strength (psi) of f'c Fracture 56,430 4490 Shear 55,360 4410 Cone Average: 4450 124 cc: TXI INDUSTRIES J. STUART TODD ARCHITECTS THE FAIN COMPANY T�r ,�: c • r ••'�cS+ Irl CTLIThomps n Texas, LLG; * :►;� * t�, .R ,J. HAMWERBERG �. .� ...... ,.... p RICHARD TWUMERBE , P 1 �o41 ,• ��c FN SENIOR PRINCIPAL ? F S tilt llit �0.�'►~� ~-• 10575 Newkirk Street, Suite 780 1 Dallas, TX 75220 1 Phone: 972 - 831 -1111 This test report relates only to the items tested and shall not be reproduced, except in full, without the written approval of CTLIThompson Texas, LLC MR.—Miu ULGairs J, I ;*& • milli IQ T E X A S L L C CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 Date: 1110512008 Report ID: K61993 - DA08152.000 Report of Concrete Compressive Strength Tests Project: ROLLING OAKS MEMORIAL CENTER PHASE / Supplier: TX/ INDUSTRIES FREEPORT PARKWAY Location: PAVING, 15' WEST OF THE NORTH CURB (MEDIAN) Cast Date: 1012412008 Ticket: 775535 Batch Time: 18:03 Concrete Mix: 8274 In -Lab Date: 1012512008 Truck Number: 1579 Test Time: 19:10 Specimens Made By: BB Initial Curing Final Curing Curing Method: Min. Temp: Max Temp: Curing Method: Other ° F ° F Fog Room Physical Properties of Concrete (ASTM C143, C231, C138, C1064) Specified Strength (fc) Slump Air Content Density Temperature 3600 psi @ 28 days 5.00 in. 2.8% 84 deg. F Compressive Strengths (ASTM C39) Specimen Age in Diameter Area Number Days (inches) (sq. inches) 1 7 4.00 12.57 2 7 4.00 12.57 r ., a OF 1 1 , CTL�Thorr� son Texasp 'OfiJ ... .................•........`.... r r r ..J. HAMMERBERG RICHARD . HAMME., 4 • a;`';r ••: SENIOR PRINCIPAL ITItA2llOfIAt`�` -�` Max. Load Compressive Percent Type of (lbs.) Strength (psi) of f'c Fracture 63,520 5050 Cone 58,700 4670 Cone Average: 4860 135 cc: TXI INDUSTRIES J. STUART TODD ARCHITECTS THE FAIN COMPANY 10575 Newkirk Street, Suite 780 1 Dallas, TX 75220 1 Phone: 972 - 831 -1111 This test report relates only to the items tested and shall not be reproduced, except in full, without the written approval of CTLIThompson Texas, LLC CTL I THOMPSON CITY OF COPPELL 255 PARKWAY BOULEVARD Date: 1110512008 P.O. BOX 478 Report ID: K61997 - DA08152.000 COPPELL TX 75019 Report of Concrete Compressive Strength Tests Project: ROLLING OAKS MEMORIAL CENTER PHASE I Supplier: TXI INDUSTRIES FREEPORT PARKWAY Location: PAVING, FREEPORT PARKWAY FIRELANE #1, 15' NE OF THE CURB (MEDIAN) Cast Date: 1012412008 Ticket: 775028 Batch Time: 10 :17 Concrete Mix: 8274 In -Lab Date: 1012512008 Truck Number: 1102 Test Time: 11 :30 Specimens Made By: BB Initial Curing Final Curing Curing Method: Min. Temp: Max Temp: Curing Method: Other o F o F Fog Room Physical Properties of Concrete (ASTM C143, C231, C138, C1064) Specified Strength (fc) Slump Air Content Density Temperature 4000 psi @ 28 days 5.50 in. 2.0% 84 deg. F Compressive Strengths (ASTM C39) Specimen Age in Number Days 1 7 2 7 CTLIThom - pson T RICHAKD J! HAMME SENIOR PRINCIPAL Diameter (inches) Area (sq. inches) 4.00 12.57 4.00 12.57 2, . . ......... h!„M.AERSERG .ti.. .• . ............�.....� jI2 tl t�0 it t ~~~ Max. Load Compressive Percent Type of (lbs.) Strength (psi) of f'c Fracture 37,110 2950 Cone 37,470 2980 Cone Average: 2960 74 cc: TXI INDUSTRIES J. STUART TODD ARCHITECTS THE FAIN COMPANY 10575 Newkirk Street, Suite 780 1 Dallas, TX 75220 1 Phone: 972 -831 -1111 This test report relates only to the items tested and shall not be reproduced, except in full, without the written approval of CTLIThompson Texas, LLC N \.�. L e i • T C v A C 1 1 !` CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 Date: 1110512008 Report ID: K61998 - DA08152.000 Report of Concrete Compressive Strength Tests Project: ROLLING OAKS MEMORIAL CENTER PHASE I Supplier: TXI INDUSTRIES FREEPORT PARKWAY Location: PAVING, FREEPORT PARKWAY FIRELANE #1, 5' WEST OF THE MEDIAN CURB (MIDDLE) Cast Date: 1012412008 Ticket: 775250 Batch Time: 12:19 Concrete Mix: 8274 In -Lab Date: 1012512008 Truck Number: 8807 Test Time: 13 :10 Specimens Made By: BB Initial Curing Final Curing Curing Method: Min. Temp: Max Temp: Curing Method: Other o F o F Fog Room Physical Properties of Concrete (ASTM C143, C231, C138, C1064) Specified Strength (f c) Slump Air Content Density Temperature 4000 psi @ 28 days 5.75 in. 3.6% 80 deg. F 2b 10575 Newkirk Street, Suite 780 1 Dallas, TX 75220 1 Phone: 972 - 831 -1111 This test report relates only to the items tested and shall not be reproduced, except in full, without the written approval of CTLIThompson Texas, LLC Compressive Strengths (ASTM C39) Specimen Age in Diameter Area Max. Load Compressive Percent Type of Number Days (inches) (sq. inches) (lbs.) Strength (psi) of f'c Fracture 1 7 4.00 12.57 38,790 3090 Cone 2 7 4.00 12.57 32,670 2600 Cone Average: 2840 71 CTLIThompson Texas, lk .'' c c : TXI INDUSTRIES •'' * r .. * J. STUART TODD ARCHITECTS �' R..1. HAM _P r THE FAIN COMPANY Z� RICHA J.: AMMER • . . 6 , • ''� 11 SENIOR PRINCIPAL Fs�.cE.N.S.f It 1 0' 2b 10575 Newkirk Street, Suite 780 1 Dallas, TX 75220 1 Phone: 972 - 831 -1111 This test report relates only to the items tested and shall not be reproduced, except in full, without the written approval of CTLIThompson Texas, LLC CTLITHOMPSON CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 Report of Concrete Compressive Strength Tests Project: ROLLING OAKS MEMORIAL CENTER PHASE I Supplier: TXI INDUSTRIES FREEPORT PARKWAY Location: PAVING, 35' NORTH OF THE SEWER DRAIN Cast Date: 1012412008 Ticket: 775456 Batch Time: 15:00 Concrete Mix: 8274 In -Lab Date: 1012512008 Truck Number: 1567 Test Time: 15:30 Specimens Made By: BB inivai curing Final Curing Curing Method: Min. Temp: Max Temp: Curing Method: Other o F o F Fog Room Physical Properties of Concrete (ASTM C143, C231, C138, C1064) Specified Strength (fc) Slump Air Content Density Temperature 4000 psi @ 28 days 5.50 in. 3.6% 84 deg. F Date: 1110512008 Report ID: K61999 - DA08152.000 Compressive Strengths (ASTM C39) Specimen Age in Number Days 1 1 7 2 7 CTL�Tho pson Texa: Diameter Area (inches) (sq. inches) 4.00 12.57 4.00 12.57 Max. Load Compressive Percent Type of (lbs.) Strength (psi) of f'c Fracture 60,240 4790 Shear 56,910 4530 Cone Average: 4660 117 cc: 7X/ INDUSTRIES J. STUART TODD ARCHITECTS THE FAIN COMPANY RICHARD -T HAMME SENIOR PRINCIPAL e • •qs tit HAi4'IMcRBE E 60610 2 k, ENS . tttZ1 11 0M «.� ;.�; ~ � 10575 Newkirk Street, Suite 780 1 Dallas, TX 75220 1 Phone: 972 - 831 -1111 This test report relates only to the items tested and shall not be reproduced, except in full, without the written approval of CTLIThompson Texas, LLC