Rolling Oaks MC-LR081030. M AS. T M EX L L C CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 Date: 1013012008 Report ID: K61962 - DA08152.000 Report of Concrete Compressive Strength Tests Project: ROLLING OAKS MEMORIAL CENTER PHASE I Supplier: TXI INDUSTRIES FREEPORT PARKWAY Location: PAVING ON FREEPORT, FIRELANE 10' EAST OF SEWER DRAIN Initial Curing Final Curing Curing Method: Min. Temp: Max Temp: Curing Method: Lab ° F 69 ° F Fog Room Physical Properties of Concrete (ASTM C143, C231, C138, C1064) Specified Strength (fc) Slump Air Content Density Temperature 4000 psi @ 28 days 5.75 in. 3.2% 80 deg. F Specimen Number 1 2 Age in Days 7 7 RICHARD J.4-#AMME SENIOR PRINCIPAL Compressive Strengths (ASTM C39) Diameter Area Max. Load Compressive (inches) (sq. inches) (lbs.) Strength (psi) 4.00 12.57 50,650 4030 4.00 12.57 50,030 3980 X111, Average: 4000 �'J. I-IANIMERBE �pE 80610 ' Q Percent of f'c 100 Type of Fracture Cone Cone cc: TXI INDUSTRIES J. STUART TODD ARCHITECTS THE FAIN COMPANY 10575 Newkirk Street, Suite 780 1 Dallas, TX 75220 1 Phone: 972 - 831 -1111 This test report relates only to the items tested and shall not be reproduced, except in full, without the written approval of CTLIThompson Texas, LLC CTLITHOMPSON CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 Date: 1013012008 Report ID: K61963 - DA08152.000 Report of Concrete Compressive Strength Tests Project: ROLLING OAKS MEMORIAL CENTER PHASE I Supplier: TXI INDUSTRIES FREEPORT PARKWAY Location: PAVING - FIRELANE 70' NORTH OF RUBY SOUTH BOUND LANE Initial Curing Final Curing Curing Method: Min. Temp: Max Temp: Curing Method: Lab ° F 68 ° F Fog Room Physical Properties of Concrete (ASTM C143, C231, C138, C1064) Specified Strength (fc) Slump Air Content Density Temperature 4000 psi @ 28 days 8.00 in. 2.6% 80 deg. F CTLIThompson Texas, RICHAR[3'J - 7 A-MMERB SENIOR PRINCIPAL ����•O T��;12tt �; ' •� V ••�cP 1 1 *, • •_...rr .I MAMMFI�,R P. 8061 It 1$IONA$'L* cc: TXI INDUSTRIES J. STUART TODD ARCHITECTS THE FAIN COMPANY 10575 Newkirk Street, Suite 780 1 Dallas, TX 75220 1 Phone: 972 - 831 -1111 This test report relates only to the items tested and shall not be reproduced, except in full, without the written approval of CTLIThompson Texas, LLC Compressive Strengths (ASTM C39) Specimen Age in Diameter Area Max. Load Compressive Percent Type of Number Days (inches) (sq. inches) (lbs.) Strength (psi) of f'c Fracture 1 7 4.00 12.57 49,620 3950 Cone 2 7 4.00 12.57 50,570 4020 Cone Average: 3980 100 CTLIThompson Texas, RICHAR[3'J - 7 A-MMERB SENIOR PRINCIPAL ����•O T��;12tt �; ' •� V ••�cP 1 1 *, • •_...rr .I MAMMFI�,R P. 8061 It 1$IONA$'L* cc: TXI INDUSTRIES J. STUART TODD ARCHITECTS THE FAIN COMPANY 10575 Newkirk Street, Suite 780 1 Dallas, TX 75220 1 Phone: 972 - 831 -1111 This test report relates only to the items tested and shall not be reproduced, except in full, without the written approval of CTLIThompson Texas, LLC T E X A S L L C CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 Date: 1013012008 Report ID: K61977 - DA08152.000 Report of Concrete Compressive Strength Tests Project: ROLLING OAKS MEMORIAL CENTER PHASE I Supplier: TXI INDUSTRIES FREEPORT PARKWAY Location: PAVING, 20' EAST OF LIGHT POLE Cast Date: 10/2212008 Ticket: Diameter (inches) Batch Time: 05:22 Concrete Mix: 8274 In -Lab Date: 1012312008 Truck Number: 1567 2 Test Time: 07:30 Specimens Made By: BB Initial Curing Final Curing Curing Method: Min. Temp: Max Temp: Curing Method: Lab o F 69 OF Fog Room Physical Properties of Concrete (ASTM C143, C231, C138, C1064) Specified Strength (f c) Slump Air Content Density Temperature 4000 psi @ 28 days 5.50 in. 4.1% 81 deg. F Compressive Strengths (ASTM C39) Specimen Number Age in Days Diameter (inches) Area (sq. inches) 1 7 4.00 12.57 2 7 4.00 1 12.57 CTLJThompson Texas, RICHAREf'J. FIWMIMERB SENIOR PRINCIPAL �•�.�tatlt \Zi E rp it : *r J. • r ;•. 80510 tIlls S /GNAL ENS; ~~ Z ttltt�A�'�ti� • ` Max. Load Compressive Percent Type of (lbs.) Strength (psi) of f'c Fracture 51,980 4140 Shear 50,770 4040 Cone Average: 4090 102 cc: TXIINDUSTRIES J. STUART TODD ARCHITECTS THE FAIN COMPANY 10575 Newkirk Street, Suite 780 1 Dallas, TX 75220 I Phone: 972 - 831 -1111 This test report relates only to the items tested and shall not be reproduced, except in full, without the written approval of CTLIThompson Texas, LLC