Loading...
ST0701-LR100420CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091193.0121 Irerracon Service Date: 04/05/10 8901 Carpenter Frwy. Report Date: 04/20/10 Revision I Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Southwestern Boulevard Attn: Keith Marvin Coppell Road to Grapevine Creek PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Sample Date: 04/05/10 Sample Time: 1040 Sampled By: Jose A. Martinez Mix ID: DCCOG501 Weather Conditions: Cloudy Supplier: Redi -Mix Accumulative Yards: 6.5 Batch Size (cy): 6.5 Batch Time: 0950 Plant: 259 Placement Method: Direct Discharge Truck No.: 1333 Ticket No.: 25181412 Water Added Before (gal):5 Water Added After (gal): 0 Field Test Data Sample Location: Abutment #4; Piers A and B Test Result Specification Placement Location: Drilled Piers, see Foundation Slump (in): 6 1/4 5 -7 Observations Report #94091193.0120, Air Content ( %): 1.4 dated 04/05/10, for pier locations Concrete Temp. (F): 76 Ambient Temp. (F): 78 Plastic Unit Wt. (pcf): 148.7 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 04/06/10 04/12/10 7 126,180 4,460 2 1 2 6.00 28:27 04/06/10 04/19/10 14 147,720 5,230 2 1 3 6.00 28.27 04/06/10 05/03/10 28 1 4 6.00 28.27 04/06/10 05/03/10 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required fie: samples. Terracon Rep.: Jose A. Martinez Reported To: Contractor: Lacy Construction Report Distribution: Reviewed By: (1) City of Coppell TX (1) City of Coppell TX (1) City of Coppell TX (2) Halff Assoc Inc (1) Lacy Construction (1) PacTrust Pacific Realty Associates LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1, 5- 21 -09, Rev.3 Page 1 of 1 Senior Project Manager