Loading...
ST0701-LR100507CONCRETE COMPRESSIVE STRENGTH TEST REPORT � Report Number: 94091 193.0132 p Service Date: 04/08110 8901 Carpenter Fiwy. Report Date: 05/07/10 Revision 2 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Southwestern Boulevard Attn: Keith Marvin Coppell Road to Grapevine Creel{ PO Box 9478 Coppell, TX Copl) ell, TX 75019 Project Number: 94091 193 Material information Sample Information Specified Strength: 4,000 l)si c7 28 days Sample Date: 04/08/10 Sample Time: 1635 Sampled By: Francisco J. Morillo Mix ID: DCCOG504 weather Conditions: Clear Supplier: Redi-Mix Accumulative Yards: 6 Batch Size (cy): 6 Batch Time: 1532 Plant: 259 Placement Method: Direct Discharge Truck No.: 1321 Ticket No.: 25183555 water Added Before (gal) :0 water Added After (gal): 0 M Feld Test Data Sample Location: See Placement Location Test Result Specification Placement Location: Bridge Beam #4 -- westbound Slump (111): 4 3M5 Air Content ( %): 4.5 3M6 Concrete Temp. (F): 87 Ambient Temp. (F): 82 Plastic Unit Wt. (pcf): 146.0 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date 'Vest Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 25.27 04/1 0/10 04/15/10 7 129 4,570 2 1 2 6.00 28.27 04110110 04/22/10 14 147,840 5 4 1 3 6.00 28.27 04110110 05/06110 28 161,370 5,710 4 1 4 6.00 28.27 04/10/10 05106110 28 160,800 5 2 Average (28 days) 5 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Set-vices: Obtain samples of fresh concrete at the llacement location4 perform required field tests and ca cony ressive strength samples. Terracon Rep.: Francisco J. Morillo Started: 1400 Reported To: Superintendent Finished: 1730 Contractor: Lacy C0 Report Distribution: oi'Co e ll Tx Reviewed By: (1) City of Ci Coppell Tx (} y pp (1) City of Coppell TX (2)14alff Assoc Inc &f cA/. Clev# nd, P.B. (1 Lacy Construction ( 1) PacTrust Pacific Realty Associates LP Senior Projecf Manager Test Methods: ASTM C 31, ASTM C39, ASTM C 13 S, ASTM C 143, ASTM C 172, ASTM 0231, ASTM C 1064, ASTM C 1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Ctttt001, 5- 2t - 0 1 ), Itev.3 Page 1 of l CONCRETE COMPRESSIVE STRENGTH TEST REPORT Repoli N[IIIl7eI`: 9409 193.0155 ra an Service Date: 04/29/10 8901 Carpenter Frwy. Report Date: 05107110 Dallas, TX 75247 214-630 -1010 Reg No: F -3272 Client Project City of Coppell TX Attn: Keith Marvin PQ Sox 9478 Coppell, TX 75019 Southwestern Boulevard Coppell Road to Grapevine Creek Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 25 days Mix ID: DCCOG504 Supplier: Redi -Mix Batch Time: 1346 Plant: 259 Truck No.: 1264 Ticket No.: 25193196 Field Test Data Test Slump (in): Air Content ( Concrete Temp. (F): Ambient Temp. (F): Plastic Unit wt. (pcf): Result Specification 3 3--5 3.3 ) 89 84 147.0 Laboratory Test Data Set Specimen Diameter No. ID (in) 1 1 6.00 Tested 6.00 3 6.00 1 4 6.00 Age at Maximum Area Date Date Test Load (sq in) Received Tested (days) (Ibs) 28.27 04/30/10 05/06/10 7 108 28.27 04/30/10 05/13/10 14 28.27 04/30/10 05127110 25 25.27 04/30/10 05127110 28 Compressive Strength Fracture (psi) Type 3,820 2 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive sti ngth samples. Terracon Rep.: Jose A. Martinez Started: 1030 Reported To: Finished: 1530 Contractor: Lacy Construction Report Distribution: (1) City «1' coppell TX (1) City of Coppell TX Reviewed By: r (1) City oI' Coppe11 TX (?) HalffAssoc Inc J. Cle e nd, P.E. ( 1) Lacy Construction (1) PacTrust Pacific Realty Associates LP renior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM 0138, ASTM 0143, ASTM 0172, ASTM 0231, ASTM 01064, ASTM 01231 Sample Date: 04/29/10 Sample Time: 1428 Sampled By: Jose A. Martinez Weather Conditions: Clear, windy Accumulative Yards: 3 Batch Size (cy): 3 Placement Method: Direct Discharge Water Added Before (gal) :O ''Water~ Added After (gal): 0 Sample Location: See Placement Location Placement Location: wingwalls, East and west side of bridge on westbound lane The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of l Crt0001.;- ?t- 01), Rev. :+ CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94091194.0065 Service Date: 04/08/10 8901 Carpenter Frwy. Report Date: 05/07/10 Revision 2 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project PacTrust Pacific Realty Associates LP Attn: Matthew Oyen 15350 SOnthWeSt Sequoia Pkwy Ste 300 Portland, OR 97224 Southwestern Boulevard Grapevine Creek to Beltline Road Coppell, TX Project Number: 94091194 Material Information Sample Information Specified Strength: 4,000 psi @n 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1449 Plant: 7 Truck No.: 7060 Ticket No.: 7215933 Field Test Data Test Slump (in): Air Content Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 2 3 -5 3.8 3 -6 75 70 149.2 Sample Date: 04/08/10 Sample Time: 1530 Sampled By: Burl E. Thomas Weather Conditions: Clear Accumulative Yards: 10 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):0 Area Water Added After (gal): 0 Sample Location: Across from Elementary School Placement Location: Inlet Bottoms and Sides, westbound No. ID Southwestern Boulevard Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 04/09/10 04/15/10 7 154,240 5,460 2 1 2 6.00 28.27 04/09/10 04/22/10 14 160,020 5,660 2 1 3 6.00 28.27 04/09/10 05/06/10 28 179,720 6,360 2 1 4 6.00 28.27 04/09/10 05/06/10 28 168,670 5,970 2 Average (28 days) 6,170 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and samples. Terracon Rep.: Burl E. Thomas Started: 1300 Reported To: Finished: 1700 Contractor: Lacy Construction Report Distribution: (1) PacTrust Pacific Realty Associates LP (1) City of Coppell TX Reviewed By: (1) City o1' Coppell TX (2) Halff Assoc Inc (I) Lacy Construction ve strength Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CRO00 1,5- 21- 09,Rev.3 Page 1 of 1