ST0701-LR100514CONCRETE COMPRESSIVE STRENGTH TEST REPORT `�'' FRI lye _f� {:r iii• x � H : i •i * e � � 8• ;1 77 3liq 6 � � • Y.' a r � i1! '� i Report Number: 94091193.0 142 1 sl3 ►... � Service Date: 04/15/1 8901 Carpenter Frwy. Report Date: 05114110 Revision 1 Dallas, TX 75247 214-630-1010 Reg No: F -3272 Client Project City of Coppell TX Southwestern Boulevard Attn: Keith Marvin Coppell Road to Grapevine Creels PG Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091193 Material Information Sample Information Specified Strength: 3,000 psi a@ 28 days Sample Date: 04115110 Sample Time: 1430 Sampled By: Burl E. Thomas Mix ID: DCB00501 Weather Conditions: Hazy Supplier: Redi -Mix Accumulative Yards: 9 Batch Size (cy): 9 Batch Time: 1319 Plant: 259 Placement Method: Direct Discharge Truck No.: 1383 Ticket No.: 251 87063 Water Added Before (gal): 10 Water Added After (gal): 0 Fi eld Test Data Sample Location: Centerline Test Result Specification Placement Location: Raprap, abutment at westbound Slump (in): 6 3 -5 Southwestern Boulevard Air Content (%): 5.0 3 -6 Concrete Temp. (F): 80 Ambient Temp. (F): 80 Plastic Unit Wt. (pcf): 147.9 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6,00 28.27 04116110 04122110 7 86 3,070 4 1 2 6.00 28.27 04116110 04/29/10 14 10 1,230 3 4 1 3 6.00 28.27 04116/10 05/13/10 28 111,260 3 4 1 4 6.00 28.27 04/16110 05/13110 28 116,180 4 4 Average (28 days) 4 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests samples. T rracon Rep.: Burl E. Thomas Started: 1330 Reported To: Finished: 1630 Contractor: Lacy Construction Report Distribution: Reviewed By: (1) City of Coppell TX ( ) C ; oco C PP e T (1) City of Coppell TX (2) Halff Assoc Inc (1) Lacy Constriction (1) PacTrust Pacific Realty Associates LP strength Eric J. Cleveland, P.E. Senior Project Manager Test Methods: ASTM C 31 , ASTM C3 9, ASTM C 13 8, ASTM C 143, ASTM C 172, ASTM C231, ASTM C 1064, ASTIR C 1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or LOOT test methods. This report s exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cRaaot, 5- 21 -09, Rev.3 Page I of I CONCRETE COMPRESSIVE STRENGTH TEST REPORT IMReport Number: 94091193.0155 a 1-con Service Date: 04/29/10 8901 Carpenter Frwy. Report Date: 05/14/10 Revision 1 Dallas, TX 75247 214 -630 -1010 Reg No: F -327 ................ Client Project City of Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Southwestern Boulevard Coppell Road to Grapevine Creep Coppell, TX Proje Number: 94091193 .................... . ... ... ........ . ..... .... Material Information Sample Information Specified Strength: 4,000 psi c@ 28 days Mix ID: DCCOG504 Supplier: Redi -Mix Latch Time: 1346 Plant: 259 Truck No.: 1264 Ticket No.: 25193196 Field Test Data Test Slump (in ): Air Content Concrete Temp. (F ): Ambient Temp. (F): Plastic Unit Wt. (pef): Result Specification 3 3 -5 3.3 3 -6 89 84 1 47.0 Laboratory Test Data Set Specimen Diameter No. ID (in} 1 1 6.00 1 2 6.00 1 3 6.00 1 4 6.00 Age at Maximum Area Date Date Test Load (sq in) Received Tested (days) (lbs) 28.27 04130/10 05106110 7 108,050 28.27 04130/10 05113110 14 1 15 28.27 04130//0 05127110 28 28.27 04/30/10 05/27/10 28 Compressive Strength Fracture (psi) Type 3,820 2 4,100 4 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cas compressi strength samples. Terracon Rep.: Jose A. Martinez Started: 1 030 Reported To: Finished: 1530 Contractor: Lacy Construction Report Distribution: Reviewed By: (1) City of Coppell TX (1) City of Coppell TX y (1) City of Coppell TX (2)1-Ialff Assoc Inc it/ leve land, P.E. (1) Lacy Constniction (1) PacTnust Pacific Realty Associates LP 0en or roj ect Manager 'Pest Methods: ASTM C 31, ASTM C3 9, ASTM C 13 8, ASTM C 143, ASTM C 172, ASTM 0231, ASTM C 1064, ASTM C 1231 Sample Date: 04129/10 Sample Time: 1428 Sampled By: Jose A. Martinez Weather Conditions: Clear, windy Accumulative Yards: 3 Batch Size (cy ): 3 Placement Method: Direct Discharge Water Added Before (gal ):O Water Added After (gal ): 0 Sample Location: See Placement Location Placement Location: Wingwalls, East and West side of bridge on westbound lane The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CRaool, 5- 31 -09, Rev.3 Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091194.0076 i re rr a o n Service Date: 04/15/10 8901 Carpenter Frwy. Report Date: 05/14/10 Revision I Dallas, TX 75247 214 -630 -1010 Reg No: F -3272 Client Project PacTrust Pacific Realty Associates LP Southwestern Boulevard Attn: Matthew Oyen Grapevine Creels to Beltline Road 15350 Southwest Sequoia Pkwy Ste 300 Coppell, TX Portland, OR 97224 Project Number: 94091194 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1142 Plant: 7 Truck No.: 7060 Ticket No.: 7216129 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 3 3 -5 5.0 3 -6 85 80 145.5 Sample Date: 04/15/10 Sample Time: 1240 Sampled By: Burl E. Thomas Weather Conditions: Hazy Accumulative Yards: 8 Batch Size (cy): 8 Placement Method: Direct Discharge Water Added Before (gal):0 Area Water Added After (gal): 0 Sample Location: 3 ft. right of centerline Placement Location: Pavement leave0ut for utility access, No. ID southbound B -Line Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 04/16/10 04/19/10 4 113,490 4,010 4 1 2 6.00 28.27 04/16/10 04/22/10 7 135,910 4,810 2 1 3 6.00 28.27 04/16/10 05/13/10 28 153,710 5,440 4 1 4 6.00 28.27 04/16/10 05/13/10 28 163,200 5,770 4 Average (28 days) 5,610 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and ast o1 res e strength samples. Teri Rep.: Burl E. Thomas Started: 1130 Reported To: Finished: 1330 Contractor: Lacy Construction Report Distribution: Reviewed By: (1) PacTnist Pacific Realty Associates LP (1) City of Coppell TX (1) City of Coppell TX (2) HalffAssoc Inc Eric J. C eveland, P.E. (1) Lacy Constnwtion Senior Pr jest Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5- 21 -09, Rev.3 Page 1 of 1