Loading...
ST0701-LR100519CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94091193.0163 Service Date: 05/04/10 8901 Carpenter Frwy. Report Date: 05/19/10 Revision 1 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City o1' Coppell TX Southwestern Boulevard Attn: Keith Marvin Coppell Road to Grapevine Creels PO Boa 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Sample Date: 05/04/10 Sample Time: 1250 Sampled By: Jesus Rojas Mix ID: DCSOHSO4 Weather Conditions: Clear Supplier: Redi -Mix Accumulative Yards: 10 Batch Size (cy): 10 Batch Time: 1222 Plant: 136 Placement Method: Direct Discharge Truck No.: 1 193 Ticket No.: 25194706 Water Added Before (gal): 10 Water Added After (gal): 0 Field Test Data Sample Location: Bridge approach Test Result Specification Placement Location: W Bridge Approach, westbound lane Slump (in): 5 3 -5 Air Content ('%): 4.5 3 -6 Concrete Temp. (F): 82 Ambient Temp. (F): 75 Plastic Unit Wt. (pef): 148.2 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 05105110 05/11/10 7 116,470 4,120 5 1 2 6.00 28.27 05105110 05/18/10 14 124,990 4,420 5 1 3 6.00 28.27 05/05/10 06/01/10 28 1 4 6.00 28.27 05105110 06/01/10 28 Comments: Samples Made By: Terracon Services: Obtain samples of fi concrete at the placement locations perform required field tests and cast compressive samples. Terracon Rep.: Jesus Rojas Started: 1100 Reported To: Finished: 1330 Contractor: Lacy Construction Report Distribution: (1) City of Coppell TX (1) City or Coppell TX Reviewed By: T - (1) City of Coppell TX (2) Halff Assoc Inc (1) Lacy Constriction (1) PacTnist Pacific Realty Associates LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CRO00 1,4- 28- 10,RevA Page 1 of 1 Senior Project Manager