Loading...
Shake & Shingle 2-LR100401 REPORT OF FIELD DENSITY TESTS Ingle Office Buildings 3 & 4 Northlake Drive and E. Belt Line Road Coppell, Texas REPORTED TO:REPORT NO. Ratcliff Constructors 22 4200 Beltway Drive REPORT DATE: 04-01-10 Addison, Texas 75001 REG PROJECT NO. 16566 ATTN: Mr. Charley Conway TECHNICIAN: D. Gazley PAGE: 1 of 2 CONTRACTOR: Ratcliff Constructors ProctorASTMOptimumMaximum No.StandardDescriptionMoisture, % Density, PCF 1 D-698 Brown sandy clay 21.8 100.2 2 D-698 Brown and reddish brown sandy clay w/gravel16.9 109.2 3 D-698 Reddish brown clayey sand 11.5 113.8 Depth Below FieldField TestFinal S. G. Density MoistureProctorCompaction No.DateLocation(feet)(pcf) (%) IDLevel (%) 33 03-15-10 Storm Line: 150’N, 35’W(1) 0.5 95.6 24.9 1 95.4 () 34 Storm Line: 40’S, 35’W(1) 0.5 96.2 24.6 1 96.0 () 35 Storm Line: 100’N, 35’W(2) 2.0 96.9 24.0 1 96.7 () 36 Storm Line: 225’N, 35’W(2) 0.5 95.4 25.5 1 95.2 () 37 Storm Line: 100’N, 35’W(2) 1.0 97.0 24.7 1 96.8 38 03-18-10 Bldg Pad 3: 40’S, 15’E(3) 0.0 111.5 12.6 3 98.0 39 Bldg Pad 3: 40’S, 60’E(3) 0.0 113.5 11.9 3 99.7 40 Bldg Pad 3: 35’S, 20’E(4) 0.0 112.2 13.1 3 98.6 41 Bldg Pad 3: 60’N, 55’E(4) 0.0 113.0 13.4 3 99.3 42 03-19-10 Bldg Pad 4: 20’N, 10’E(5) 0.0 112.2 14.2 3 98.6 43 Bldg Pad 4: 50’N, 65’E(5) 0.0 112.4 14.4 3 98.8 44 Bldg Pad 4: 25’N, 60’E(5) 0.0 111.3 12.6 3 97.8 45 Bldg Pad 4: 60’N, 10’E(5) 0.0 112.5 13.8 3 98.9 Comments: Where tested, materials were in compliance with project specifications. () Indicates passing retest from 02-19-10, Report No. 15. 2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 [214] 350 5600 [214] 350 0019 TELFAX REPORT NO. 22 REPORT DATE: 04-01-10 REG PROJECT NO. 16566 PAGE: 2 of 2 Footnotes: (1) Measurements referenced from N.W. corner of Building 3. (2) Measurements referenced from N.W. corner of Building 4. (3) Measurements referenced from N.E. corner of Building 3. (4) Measurements referenced from N.E. corner of Building 4. (5) Measurements referenced from S.W. corner of Building 4. Submitted by: E-Mail Distribution: (1) Ratcliff Constructors/ REED ENGINEERING GROUP, LTD. Mr. Charley Conway Registration Number F-3114 (1) City of Coppel/Mr. Larry Davis (1) City of Coppell/Mr. Mike Arellano (1) Ratcliff Constructors/Mr. Derek Free Mail Bill Woolwine Distribution: (1) Pross Design Group/Mr. Mark Pross Sr. Manager, CMT BW/cn REPORT OF OPTIMUM MOISTURE/MAXIMUM DENSITY CURVE Ingle Office Buildings 3 & 4 Northlake Drive and E. Belt Line Road Coppell, Texas REPORTED TO:REPORT NO Ratcliff Constructors . 30 4200 Beltway Drive REPORT DATE: 04-14-10 Addison, Texas 75001 REG PROJECT NO . 16566 ATTN: Mr. Charley Conway SAMPLE DATE: 04-05-10 CONTRACTOR: Ratcliff Constructors CurveOptimumMaximum Density, No.Soil Classification Proctor Type Moisture, % pcf Brown sandy clay 5(lime-treated)ASTM D-698 17.8103.6 104.0 ) 4.5 f s )103.5 t f ( 4.0 c 103.0 r p e ( t 3.5 102.5 t e h 102.0 m g 3.0 i o er 101.5 t e W2.5 101.0 n y e r 100.5 2.0 P D t t100.0 i e 1.5 nk 99.5 c U o 99.0 1.0 P 14.0 16.0 18.0 20.0 22.0 14.0 16.0 18.0 20.0 22.0 Moisture Content (%)Moisture Content (%) E-MailSubmitted by: Distribution: (1) Ratcliff Constructors/ REED ENGINEERING GROUP, LTD. Mr. Charley Conway Registration Number F-3114 (1) City of Coppel/Mr. Larry Davis (1) City of Coppell/Mr. Mike Arellano (1) Ratcliff Constructors/ Mr. Derek Free Mail Bill Woolwine Distribution: (1) Pross Design Group/ Sr. Manager, C.M.T. Mr. Mark Pross BW/rt 2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 [214] 350 5600 [214] 350 0019 TELFAX CONCRETE CYLINDER TEST REPORT Ingle Office Buildings 3 & 4 Northlake Drive and E. Belt Line Road Coppell, Texas REPORTED TO:REPORT NO. Ratcliff Constructors 24 4200 Beltway Drive REG PROJECT NO. 16566 Addison, Texas 75001 SAMPLE DATE: 04-01-10 ATTN: Mr. Charley Conway TECHNICIAN: G. Tsougarakis PAGE: 1 of 1 CONTRACTOR: Ratcliff Constructors Location of Sample Set Number Location Quantity Represented 1 Building 3 Pier: C-6 5/45 Design Information Source of Concrete Mix Identification Specified Strength (psi) TXI 9506 3000 Test Results SetCylinder Age @ Total Load Compressive Average No.IDDate Tested Test(lbs.)Strength (psi) Strength (psi) 1 9808 04-08-10 7 57730 4590 9808 04-29-10 28 79840 6350 9808 04-29-10 28 82090 6530 6440 9808 Hold H Cylinder Data AirConcreteAirUnit SetCylinder SlumpTime of TemperatureTemperatureEntrainmentWeightTicket 3 No.ID(inches)Sample(°F)(°F)(%) (lbs/ft)Number 1 9808 5.0 3:30 AM 65 78 0.8 149.0 982133 Note: (1) Concrete was sampled in accordance with ASTM C-31 (2) Concrete cylinders were tested in accordance with ASTM C-39 E-MailSubmitted by: Distribution: (1) Ratcliff Constructors/ REED ENGINEERING GROUP, LTD. Mr. Charley Conway Registration Number F-3114 (1) City of Coppel/Mr. Larry Davis (1) City of Coppell/Mr. Mike Arellano (1) Ratcliff Constructors/Mr. Derek Free (1) Pavecon Commercial Concrete/ Mr. Chad Robertson Mickey Lawson Assistant Manager, CMT Mail ML/rt Distribution: (1) Pross Design Group/Mr. Mark Pross 2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 [214] 350 5600 [214] 350 0019 TELFAX