Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Shake & Shingle 2-LR100314
REPORT OF PIER OBSERVATION Ingle Office Buildings 3 & 4 Northlake Drive and E. Belt Line Road Coppell, Texas REPORTED TO:REPORT NO. Ratcliff Constructors 25 4200 Beltway Drive REPORT DATE: 03-14-10 Addison, Texas 75001 REG PROJECT NO. 16566 ATTN: Mr. Charley Conway TECHNICIAN: G. Tsougarakis PAGE: 1 of 1 CONTRACTOR: Ratcliff Constructors Building 3 Pier Diameter Bell Diameter Depth Before Final Depth Concrete DatePier No. (inches)(inches)Bell (feet) of Pier (feet) Length (feet) 03-31-10 B-2 24 48 18.2 19.4 19.3 B-3 24 48 18.3 19.0 18.1 B-4 24 48 18.6 16.8 18.5 A-1 24 48 15.9 16.1 15.4 A-2.5 24 48 16.2 16.4 14.7 A-2 24 48 18.0 18.6 17.0 A-2.5 24 48 18.4 18.8 16.7 A-3.0 24 48 18.4 18.8 16.7 A-3.5 24 48 18.0 18.5 16.7 04-01-10 A.7-1 24 48 18.0 20.0 17.6 B.3-1 24 48 18.0 19.5 17.0 C-1 24 48 18.0 20.0 17.6 D-1.5 24 48 17.5 20.0 16.0 D-3 24 48 18.0 18.5 16.0 B.9-3 24 48 19.0 19.3 18.0 B.9-15 24 48 18.0 21.1 17.0 D-2 24 48 18.6 20.0 16.0 D-2.5 24 48 18.0 20.6 16.6 D-3.5 24 48 18.0 19.0 18.0 B.9-2.5 24 48 19.0 19.8 15.8 B.9-4 24 48 18.0 18.2 15.8 D-4 24 48 10.0 11.0 9.5 C-6 24 48 10.5 11.4 10.0 Reinforcing Steel: 24” 6-#7 bars with #3 ties at 18 inches O.C. E-MailSubmitted by: Distribution: (1) Ratcliff Constructors/ REED ENGINEERING GROUP, LTD. Mr. Charley Conway Registration Number F-3114 (1) City of Coppel/Mr. Larry Davis (1) City of Coppell/Mr. Mike Arellano (1) Ratcliff Constructors/Mr. Derek Free Mail Distribution: (1) Pross Design Group/Mr. Mark Pross Ronald F. Reed, P.E. BW/mg 2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 [214] 350 5600 [214] 350 0019 TELFAX REPORT OF PIER OBSERVATION Ingle Office Buildings 3 & 4 Northlake Drive and E. Belt Line Road Coppell, Texas REPORTED TO:REPORT NO. Ratcliff Constructors 27 4200 Beltway Drive REPORT DATE: 04-14-10 Addison, Texas 75001 REG PROJECT NO. 16566 ATTN: Mr. Charley Conway TECHNICIAN: G. Tsougarakis PAGE: 1 of 1 CONTRACTOR: Ratcliff Constructors Building 3 ShaftRequiredDepth to Total DepthActualConcrete Size PenetrationStratumof Pier PenetrationLength DatePier No. (inches)(feet)(feet)(feet)(feet)(feet) 04-01-10 B-5 24 6.0 23.0 29.5 6.5 29.5 Reinforcing Steel: 6-#7 bars with #3 ties at 18 inches O.C. Note: Pier required use of temporary casing. Submitted by: E-Mail Distribution: (1) Ratcliff Constructors/ REED ENGINEERING GROUP, LTD. Mr. Charley Conway Registration Number F-3114 (1) City of Coppel/Mr. Larry Davis (1) City of Coppell/Mr. Mike Arellano (1) Ratcliff Constructors/Mr. Derek Free Mail Distribution: (1) Pross Design Group/Mr. Mark Pross Ronald F. Reed, P.E. BW/mg 2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 [214] 350 5600 [214] 350 0019 TELFAX