Loading...
Shake & Shingle 2-LR100608 CONCRETE CYLINDER TEST REPORT Ingle Office Buildings 3 & 4 Northlake Drive and E. Belt Line Road Coppell, Texas REPORTED TO:REPORT NO. Ratcliff Constructors 39 4200 Beltway Drive REG PROJECT NO. 16566 Addison, Texas 75001 SAMPLE DATE: 05-11-10 ATTN: Mr. Charley Conway TECHNICIAN: R. Hollings PAGE: 1 of 2 CONTRACTOR: Ratcliff Constructors Location of Sample Set Number Location Quantity Represented 1 Building 3 Panels: No. 4 30/266 2 Building 3 Panels: No. 18 110/266 3 Building 4 Panels: No. 2 210/266 Design Information Source of Concrete Mix Identification Specified Strength (psi) TXI 0047 4000 Test Results SetCylinder Age @ Total Load Compressive Average No.IDDate Tested Test(lbs.)Strength (psi) Strength (psi) 1 511 05-18-10 7 54110 4310 511 06-08-10 28 76410 6080 511 06-08-10 28 76350 6070 6080 511 Hold H 2 512 05-18-10 7 53680 4270 512 06-08-10 28 67710 5390 512 06-08-10 28 73710 5870 5630 512 Hold H 3 513 05-18-10 7 47930 3810 513 06-08-10 28 62080 4940 513 06-08-10 28 60850 4840 4890 513 Hold H 2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 [214] 350 5600 [214] 350 0019 TELFAX REPORT No. 39 REG Project No. 16566 SAMPLE Date: 05-11-10 PAGE: 2 of 2 Cylinder Data AirConcreteAirUnit SetCylinder SlumpTime of TemperatureTemperatureEntrainmentWeightTicket 3 No.ID(inches)Sample(°F)(°F)(%) (lbs/ft)Number 1 511 5.0 4:25 AM 64 68 1.3 149.4 996295 2 512 4.0 5:45 AM 66 74 1.7 149.7 996303 3 513 5.0 7:45 AM 70 78 1.2 149.4 996327 Note: (1) Concrete was sampled in accordance with ASTM C-31 (2) Concrete cylinders were tested in accordance with ASTM C-39 Submitted by: E-Mail REED ENGINEERING GROUP, LTD. Distribution: (1) Ratcliff Constructors/ Registration Number F-3114 Mr. Charley Conway (1) City of Coppel/Mr. Larry Davis (1) City of Coppell/Mr. Mike Arellano (1) Ratcliff Constructors/Mr. Derek Free (1) McHale Engineering/ Mickey Lawson Mr. Gary McHale Assistant Manager, CMT (1) Pavecon Commercial Concrete/ ML/rt Mr. Chad Robertson Mail Distribution: (1) Pross Design Group/Mr. Mark Pross REPORT OF STRUCTURAL STEEL OBSERVATION Ingle Office Buildings 3 & 4 Northlake Drive and E. Belt Line Road Coppell, Texas REPORTED TO:REPORT NO. Ratcliff Constructors 42 4200 Beltway Drive REPORT DATE: 06-09-10 Addison, Texas 75001 REG PROJECT NO. 16566 ATTN: Mr. Charley Conway DATE OBSERVED: 06-08-10 TECHNICIAN: J. Gray PAGE: 1 of 1 CONTRACTOR: Ratcliff Constructors Location: Building 4 NonCode Details Observed CompliantCompliant AWS D1.1 AISC Other I) Anchor bolt tension verification of X X steel columns II) Random visual weld verification as follows: a) girder to wall connections X X b) girder to steel column X X connections c) steel joist to girder connections X X d) steel joist to wall connections X X III) Visual weld verification of X X welded steel roof deck IV) Visual verification of Tek screw X X installation at roof deck side laps Other = Structural Drawings Submitted by: E-Mail Distribution: (1) Ratcliff Constructors/ REED ENGINEERING GROUP, LTD. Mr. Charley Conway Registration Number F-3114 (1) City of Coppel/Mr. Larry Davis (1) City of Coppell/Mr. Mike Arellano (1) Ratcliff Constructors/Mr. Derek Free (1) McHale Engineering/ Mr. Gary McHale James D. Gray Mail C.W.I. 07081171 Distribution: (1) Pross Design Group/Mr. Mark Pross JG/cdl 2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 [214] 350 5600 [214] 350 0019 TELFAX