Loading...
Shake & Shingle 2-LR100617 REPORT OF FIELD DENSITY TESTS Ingle Office Buildings 3 & 4 Northlake Drive and E. Belt Line Road Coppell, Texas REPORTED TO:REPORT NO. Ratcliff Constructors 47 4200 Beltway Drive REPORT DATE: 06-17-10 Addison, Texas 75001 REG PROJECT NO. 16566 ATTN: Mr. Charley Conway TECHNICIAN: T. Gleaves PAGE: 1 of 2 CONTRACTOR: Ratcliff Constructors ProctorASTMOptimumMaximum No.StandardDescriptionMoisture, % Density, PCF 1 D-698 Brown sandy clay 21.8 100.2 2 D-698 Brown and reddish brown sandy clay w/gravel16.9 109.2 3 D-698 Reddish brown clayey sand 11.5 113.8 4 D-698 Reddish tan clayey sand 11.1 117.2 5 D-698 Brown sandy clay (lime-treated) 17.8 103.6 Depth Below FieldField TestFinal S. G.Density MoistureProctorCompaction No.DateLocation(feet)(pcf) (%) IDLevel (%) 51 06-02-10 Bldg 3 Leave-out: 1’S, 35’W(1) 0.0 104.2 20.1 2 95.4 52 Bldg 3 Leave-out: 40S, 69’W 0.0 103.9 20.4 2 95.1 53 Bldg 3 Leave-out: 160’S, 69’W(1) 0.0 105.1 19.7 2 96.2 54 Bldg 3 Leave-out: 199’S, 65’W(1) 0.0 104.7 19.5 2 95.9 55 Bldg 3 Leave-out: 180’S, 1’W(1) 0.0 106.1 18.9 2 97.2 56 Bldg 3 Leave-out: 60’S, 1’W(1) 0.0 105.5 19.3 2 96.6 57 06-03-10 Bldg 4 Leave-out: 30’N(2) 0.5 103.5 14.6 2 94.7(*) 58 Bldg 4 Leave-out:120’N(2) 0.7 97.9 17.9 2 89.6(*) 59 Bldg 4 Leave-out: 30’S(3) 0.5 104.0 10.4 2 95.2(*) 60 Bldg 4 Leave-out: 30’W(3) 0.5 98.5 20.2 2 90.2(*) 61 Bldg 4 Leave-out: 54’S(4) 0.2 101.0 13.1 2 92.0(*) 62 Bldg 4 Leave-out:87’N(5) 0.3 91.7 12.5 2 83.9(*) 63 Bldg 4 Leave-out: 18’N(5) 0.5 117.5 8.0 2 107.6(*) 64 Bldg 4 Leave-out: 33’E(5) 0.2 101.5 15.6 2 92.9(*) 2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 [214] 350 5600 [214] 350 0019 TELFAX REPORT NO. 47 REPORT DATE: 06-17-10 REG PROJECT NO. 16566 PAGE: 2 of 2 Comments: Where tested, materials were in compliance with project specifications, unless noted otherwise. (*) Indicates failing test, not retested as of this report. Footnotes: (1) Measurements referenced from N.E. corner of Building 3. (2) Measurements referenced from S.E. corner of Building 4. (3) Measurements referenced from N.E. corner of Building 4. (4) Measurements referenced from N.W. corner of Building 4. (5) Measurements referenced from S.W. corner of Building 4. E-MailSubmitted by: Distribution: (1) Ratcliff Constructors/ REED ENGINEERING GROUP, LTD. Mr. Charley Conway Registration Number F-3114 (1) City of Coppel/Mr. Larry Davis (1) City of Coppell/Mr. Mike Arellano (1) Ratcliff Constructors/Mr. Derek Free (1) McHale Engineering/ Mr. Gary McHale Bill Woolwine Mail Sr. Manager, CMT Distribution: (1) Pross Design Group/Mr. Mark Pross BW/cdl