Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MA1001-CS100504
2010) George Marshall -Need Contact Information Page 1 From: Rhonda Adloo Subject: Need Contact Information >>> "Chris Renzi" < crenzi redflex.com 5/4/2010 4:13 PM >>> Mr. Marshall, According to the construction plans on the server released for construction on May 14, 2007; the Redflex control cabinet obtains power from the existing city power pole at the NE corner. We enter the existing conduit at the j -box just outside the traffic signal cabinet. When are you planning on changing to the underground power service? Let me know if you have any further questions or concerns. Chris Renzi Construction Manager Redflex Traffic Systems, Inc. (915) 727 -1990 Cell crenzi redflex.com - - - -- Original Message---- - From: George Marshall [ mai Ito g marshal l(aD-coppelltx.gov] Sent: Tuesday, May 04, 2010 4:07 PM To: Chris Renzi Subject: Re: Need Contact Information Chris, understand you are the person to talk to about power to the Redflex controller. Currently there is a power pole on the northeast corner of the intersection of Denton Tap & sandy Lake. It is our desire to remove the pole and run underground power to the traffic signal cabinet. How is the Redflex camera obtaining power? Thank You, George George Marshall, PE City of Coppell Engineering 972 - 304 -3562 >>> "Kimberly Chinchilla" < kch inch illa(a 5/3/2010 4:39 PM >>> Our Construction Manager, Chris Renzi, should be able to help. His contact information is as follows. Email: crenzi redflex.com Cell: 915- 727 -1990 Thanks, Kim Sent from Blackberry 2010) George Marshall -Need Contact Information Page 2 From: James Cook < icook _coppelltx.gov To: Kimberly Chinchilla Cc: George Marshall < G MARSHAL L(a Sent: Mon May 03 14:39:30 2010 Subject: Need Contact Information Kim, need some contact information for a person from Redflex who can answer some questions about how the camera system at Sandy Lake and Denton Tap (SLDT) obtains its power. The city is considering moving a power pole at the southeast corner of the intersection in conjunction with the upcoming intersection reconstruction. It is possible that the Redflex equipment is drawing its power off of that pole. George Marshall is a Civil Engineer for the city and needs to know if that pole is moved /removed if it will have any effect on any of the Redflex equipment. Please send him the contact information of the correct person to speak with from your company regarding this issue. George can be reached via email at g marshal l(a or by phone at 972 - 304 -3562. Thanks in advance for your help with this matter. Jim RELEASED FOR CONSTRUCTION MAY 14, 2007 DENTON TAP RD AT SANDY LANE RD Raytheon Lewisville 'llsta \ Ridge Blvd Bus cr � 448A 121 m P :ek Pky� % LISA Frankford R lower Mound CD 446 - /- - S�'_. -<:�C .4456 121 T Enterprise D" o� 54 \ D__- — 553 a - Deforest Rd 2499 y � Ar W ParkW a ��{{ r� ° a oPPell ! M dcg ti r c =U � m Jl� O ^kway Blvd Q W Sandy Lake Rd z o I o Carrollton Q vin Sandy Lake Rd� E Sandy Lake F JIIIJj l� - �) �- ? a� j o }` yd San 26 T _ r Dr - wneei Plantat� lll - - lr r t ar le !_ Park L" l MACARTHUR BLVD AT SANDY LAKE RD ` CI O E Bethel School Rd �� e �+� ✓ \ �t Mcinnisn �u Bethel 0 dy - /� Ir !� Park JIvJ�_ F- 1 Q . — +�+= Bethel Rd , -- - C �e�ti X Rd Rfverchase s �Y� ° __ - - - 121 0. ° Dallas �� — - - - 'ne Rd — CIL ° a m a Southwftt Blvd Wort h Dallas fort —� Airline Or Ai � 3 a 11 LL J Int rar ! No,ti /t Lake Cl;itsrae Dr 0 MACARTHUR BLVD AT BEET F N E R D rt � Wrangler Dr 03 o J �, 'Lake �a F2MTC811 W ` Park Sad .l�� f (� ill '' II ' � 11a _ ,�:, C; 36-on Trail N GENERAL- NOTES: 1. ALL TRAFFIC SIGNAL EQUIPMENT AND ALL CONSTRUCTION IN PUBLIC RIGHT -OF -WAY OR IN EASEMENTS GRANTED FOR PUBLIC USE SHALL CONFORM TO THE STATES DEPARTMENT OF TRANSPORTATION (D.O.T.) STANDARD DRAWINGS AND SPECIFICATIONS, THE CITY POLICY MANUALS AND THE CITY TRAFFIC SIGNAL SPECIAL REQUIREMENTS. 2. TRAFFIC CONTROL SHALL CONFORM TO THE CITY "TRAFFIC CONTROL MANUAL" AND /OR AS DIRECTED BY THE CITY PUBLIC WORKS INSPECTOR. 3. UTILITY LOCATIONS SHOWN ARE BASED UPON THE BEST AVAILABLE INFORMATION. THE CONTRACTOR SHALL CONTACT THE UTILITY LOCATING COMPANY BEFORE CONSTRUCTION AND VERIFY ACTUAL UTILITY LOCATIONS. 4. ALL EQUIPMENT MUST BE LOCATED WITHIN THE RIGHT -OF -WAY 5, ALL EXISTING UTILITIES SHOWN WITHIN THE PLANS ARE PROVIDED BY THE BEST AVAILABLE INFORMATION PROVIDED BY COOPERATING UTILITY COMPANIES. NEITHER REDFLEX, THE CITY NOR THE STATE DOT. ASSUME RESPONSIBILITY AS TO THE PRECISE LOCATION OR ACCURACY OF SHOWN UTILITIES. THE CONTRACTOR SHALL PROPERLY FIELD VERIFY UTILITY LOCATIONS AND SHALL PROPERLY PROTECT, MAINTAIN AND /OR REPAIR ANY DAMAGE OF ALL KNOWN AND ANY EXPOSED UNKNOWN UTILITIES SHOWN WITHIN THE PLANS. REDFLEX, THE CITY AND THE STATE D.O.T. ASSUME NO LIABILITY RESULTING IN POSSIBLE DEFICIENCIES IN UTILITY LOCATIONS AND NO REMEDIAL OR ADDITIONAL COMPENSATION WILL BE ALLOWED. 6. PROTECT IN PLACE ALL CITY SIGNAL EQUIPMENT AND LOOPS. ANY EQUIPMENT OR LOOPS DAMAGED AS A RESULT OF THIS INSTALLATION WILL BE RESTORED AT THE COST OF THE CONTRACTOR. A (3)HEAVY HEX NUTS PER BOLT (1)HARD WASHER PER BOLT A a" THK STEEL TEMPLATE (TOP), g" THK STEEL Q TEMPLATE (BOTTOM) SEE POLE SCHEDULE FOR POLE HEIGHT VIDEO VEHICLE DETECTOR CAMERA S.S. BANDING TO LUMINAIRE POLE W /SIAMESE CABLE ROUTED THROUGH REDFLEX FLASH POLE, REDFLEX CONDUIT AND BACK T0. REDFLEX CABINET. w_o z REDFLEX FLASH POLE az z o a� �Q az o SIAMESE CABLE ROUTED BACK. TO REDFLEX CABINET o i FOR CONFIGURATION REDFLEX CABINET P NEW JUNCTION BOX IR A i NEW CONDUIT STUB FROM NEW CONDUIT W /SIAMESE CABLE REDFLEX CABINET TO ROUTED THROUGH CONDUIT AND EXISTING JUNCTION BOX INTO NEW REDFLEX CONDUIT AT NEW JUNCTION BOX PLATE FLASH AND VIDEO VEHICLE RED LIGHT CAMERA SYSTEM DETECTOR CAMERA ON REDFLEX POLE SCALE: N.T,S. (1) LOCKWASHER� PER BOLT 14 y" 1 41 "0 BAR TACK WELD 3 17 3° B.C. PLACES (TYP) SECTION A ANCHOR BOLT ASSEMBLY RED LIGHT CAMERA SYSTEM SCALE: N.T.S. SECTION VIEW TOP VIEW 2' -4" SIDE 2 -4" W /DOOR GROUND ROD SIDEWALK z�z °!; P, .� j. 4 'X15' GROUND 2"0 TYP. ANCHOR BOLT (VERIFY BOLT HOLE ROD SPACING W /RTS BASE PRIOR TO INSTALLATION NOTE: SEAL CABINET AND FOUNDATION JOINT WITH OUTDOOR GRADE SILICONE SEALANT. CABINET FOUNDATION RED LICHT CAMERA SYSTEM (REDUGHT) SCALE: N.T.S. 4 "O STD. GALVANIZED STEEL PIPE (ATM A53 SCH 40 4 2 1 " O.D.) o FRANGIBLE BASE (CASE ALUMINUM OR CAST IRON) 14" SQUARE AT THE BASE GROUND LINES SIDEWALK OR ISLAND N 1 "X36 "X4" LENGTH AS I �� o REQUIRED BY MANUFACTURER` GROUND ROD (3/4 ") /\ j / / /; BOUNDED TO POLE & BACK TO RTS 23 (MIN.) CABINET H 1 0 ANCHOR BOLTS - f B C-' (4)X36" (ASTIR) A -36 OR FOUNDATION A -307 13 2' BOLT CIRCLE . 4_ J ° TEMPLATE -� FOUNDATION MAY BE ROUND OR SQUARE POLE - TYPE 1 RED LIGHT CAMERA SYSTEM SCALE: N.T.S. NOT CO SCALE SEAL CAST ALUMINUM J A POLE CAP W /(3) S.ST'L SET SCREWS r w SEE ANCHOR BOLT F Q ASSEMBLY z G WITH 6"X6" WEIDED o �m ° o a 0 zo WIRE FABRIC 0 SECTION A -A ALUMINUM REINFORCEMENT l4t�' TRANSFORMER BASE A G 6 - VERTICAL " REINFORCEMENT BARS GROUND ROD BOUNDED A TO POLE & BACK TO 30 POLE ASSEMBLY RTS CABINET I RED LIGHT CAMERA SYSTEM SCALE: N. 5C 2 2.$ A RELEASED FOR CONSTRUCTION MAY 14, 2007 11E- 10.00x6.05x28' -3" ROUND zo STEEL MONOTUBE (.14 ITALY TAPER) z o FRANGIBLE BASE (CASE ALUMINUM) "� FOUNDATION SHALL BE EVEN WITH FINISHED GRADE (1:6 GROUND LINE `ro 2' 1 MAX NEGATIVE SIDE SLOPE) 2 -6° j 1 a "0 ANCHOR BOLTS 6' -6 "0 (4)x30'; 17 "° BOLT CIRCLE PALE - TYPE 2 RED LIGHT CAMERA SYSTEM SCALE: NS.S. "'0 MIN. POLYPROPYLENE PULL ROPE �a EXISTING TELCO PEDESTAL RTS HUB AND /OR ROUTER CABINET (REDFLEX OR TELCO PROVIDER) S Q �-- D PROVIDE 4' E6 SOLID o >? GROUND WIRE BOUNDED n TO CABINET GROUND ROD 3 MIN, .v i RAD IF (TYP.) ROUGH IN CONDUIT NEXT TO _ /GROUND ROD PEDESTAL, INSTALL PULL ROPE TO RTS CABINET. 2" RIGID STEEL CONDUIT W /PULL ROPE INSTALLED. NOTE CONTRACTOR TO LEAVE RADIUS SWEEPS EXPOSED UNTIL INSPECTED AND ACCEPTED BY TELCO. CONTRACTOR SHALL ENSURE PUBLIC SAFETY AROUND INSPECTION HOLES. PEDESTAL CONNECTION (TYP) RED LIGHT CAMERA SYSTEM (UNDERGROUND) SCALE: NT.S. (� J A r F 4" CONCRETE RIPROP z G WITH 6"X6" WEIDED 1 WIRE FABRIC P F REINFORCEMENT l4t�' o xi G 6 - VERTICAL " REINFORCEMENT BARS GROUND ROD BOUNDED " TO POLE & BACK TO .875 4 RTS CABINET 2 -6° j 1 a "0 ANCHOR BOLTS 6' -6 "0 (4)x30'; 17 "° BOLT CIRCLE PALE - TYPE 2 RED LIGHT CAMERA SYSTEM SCALE: NS.S. "'0 MIN. POLYPROPYLENE PULL ROPE �a EXISTING TELCO PEDESTAL RTS HUB AND /OR ROUTER CABINET (REDFLEX OR TELCO PROVIDER) S Q �-- D PROVIDE 4' E6 SOLID o >? GROUND WIRE BOUNDED n TO CABINET GROUND ROD 3 MIN, .v i RAD IF (TYP.) ROUGH IN CONDUIT NEXT TO _ /GROUND ROD PEDESTAL, INSTALL PULL ROPE TO RTS CABINET. 2" RIGID STEEL CONDUIT W /PULL ROPE INSTALLED. NOTE CONTRACTOR TO LEAVE RADIUS SWEEPS EXPOSED UNTIL INSPECTED AND ACCEPTED BY TELCO. CONTRACTOR SHALL ENSURE PUBLIC SAFETY AROUND INSPECTION HOLES. PEDESTAL CONNECTION (TYP) RED LIGHT CAMERA SYSTEM (UNDERGROUND) SCALE: NT.S. (� J A F C G D 5 C F G 1.675 36 5 F e .875 4 4.25 F I G 3.26 5 5C 2 2.$ A b k E " PHOTO N ENFORCED , RlOxIST A B C D E F G H K L M 2A .375 625 fJ COLORS LEGEND OUCK .REE'YELLO'AANOGREEN(usho.11 6ACKGROUND- 'MHITE(RFTROREAECTNE) �S DRAWN By JL REVIEWED BY CITY STAFF APPROVED BY: CITY OF. REDFLEX COPPELL oESCRIPnoN fo DESIGNED BY: DEPARTMENT INITIAL RATE JB PUBLIC WORKS (OPER.) TRAFFIC SYSTEMS CHECKS° °Y PUBLIC WORKS (ENV, PU °LIB WORKS °IRECTOR � CITY ENGINEER D ATE REDLIGHT PHOTO ENFORCEMENT 15020 N. 74TH STREET Pl19LlC WORKS W - ( ATER 7 RECOMMENDED BY: RECOMMENDED BY: SCOTTS DALE, AS 85260 RECOMMENDED By PH: 480 607 0705 PUBLIC WORKS 1TRAT.) DETAIL(S) FIRE DEPT. DEPUTY CITY ENGINEER DEVELOPMENT SERVICES DRAWING N0. 3027 -102 5 C C 1 1.675 36 5 59 . .625 . .875 4 4.25 F F.75 7 7.5 3 3.26 5 5C 2 2.$ A AS 2 225 SERVICES DRAWING N0. 3027 -102 DRAWING N0. 3027 -102 CONSTRUCTION NOTES ❑i INSTALL FOUNDATION AND REDFLEX CONTROL CABINET, 5/8 "x15' GROUND ROD AND BOND TO CABINET AND POLE BASES WITH #8 BARE Cu. SEE CABINET FOUNDATION DETAIL. 0 CONTRACTOR SHALL TERMINATE AND LAND ALL POWER CIRCUITS INTO REDFLEX CABINET, [31 INSTALL INLINE FUSE HOLDER ON RED PHASE CONDUCTOR WITH 5 AMP FUSE INSIDE REDFLEX CABINET TO PROTECT CITY TRAFFIC CABINET. ® INSTALL A 40 AMP CIRCUIT BREAKER INTO NEW REDFLEX POWER PANEL FOR 120V SUPPLY TO REDFLEX CABINET. 0 TERMINATE #14 WIRE TO RED PHASE AND NEUTRAL INSIDE CITY TRAFFIC CABINET_ SEE CONDUCTOR SCHEDULE FOR APPROACHES. (NOTE: MUST BE DONE MONDAY- THURSDAY. NOTIFY THE TRAFFIC OPERATIONS DEPARTMENT OF THE CITY 24 HOURS BEFORE CONNECTION) © INSTALL JUNCTION BOX OF THE SIZE AND TYPE PER STANDARDS OF THE CITY - VERIFY BEFORE INSTALLATION. ❑7 INSTALL VIDEO VEHICLE DETECTION CAMERA ON 30' POLE. ROUTE CCTV CABLE BACK TO RTS CABINET. ® INSTALL FOUNDATION POLE AND GROUND ROD FOR REDFLEX EQUIPMENT- SEE DRAWING FOR LOCATION. SEE POLE DETAIL. ❑D INSTALL CAMERA AND FLASH ENCLOSURE ON REDFLEX POLE; AIM AT MONITORED APPROACHES. INCLUDE 3 #14 AWG CONDUCTOR CABLES FROM CAMERA ENCLOSURE TO FLASH. 0INSTALL A 250 WATT FLASH UNIT ON REDFLEX POLE, AIM AT MONITORED APPROACHS. T1 CONNECT POLE TO SOLID BARE BOND GROUND AND GROUNDING ROD IN POLE FOUNDATION AND TO SYSTEM GROUND BONDED BACK AT THE REDFLEX CABINET. I2 TRACER WIRE TO BE RUN THROUGH ALL CONDUIT FROM THE REDFLEX CABINET TO ALL REDFLEX EQUIPMENT. 10 CONDUIT TO BE BORED UNDER ROADWAY TO MIN. STANDARD COVER DEPTH REQUIRED BY THE CITY (24" MINIMUM). 14 EXISTING SIGNAL HEADS HAVE LED'S INSTALLED. IF NEEDED ADJUST SIGNAL HEAD SO IT IS VISIBLE TO THE REDFLEX CAMERA, MUST BE DONE WITH CITY SUPERVISION. 15 REFRESH STRIPING (VIOLATION LINE AND LANES ETC) AS NEEDED AT THE MONITORED APPROACHES, 1TR TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #1 (HOT AND NEUTRAL). 0 TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #2 (HOT AND NEUTRAL). MUST VERIFY EXISTING UTILITY INFO AND LOCATION GENERAL NOTES 1. ALL EXISTING UTILITIES SHOWN WITHIN THE PLANS ARE PROVIDED BY THE BEST AVAILABLE INFORMATION PROVIDED BY COOPERATING UTILITY COMPANIES. NEITHER REDFLEX NOR THE CITY A55UME RESPONSIBILITY AS TO THE PRECISE LOCATION OR ACCURACY OF SHOWN UTILITIES. THE CONTRACTOR SHALL PROPERLY FIELD VERIFY UTILITY LOCATIONS AND SHALL PROPERLY PROTECT, MAINTAIN AND /OR REPAIR ANY DAMAGE OF ALL KNOWN AND ANY EXPOSED UNKNOWN UTILITIES SHOWN WITHIN THE PLANS. REDFLEX AND THE CITY ASSUME NO LIABILITY RESULTING IN POSSIBLE DEFICIENCIES IN UTILITY LOCATIONS AND NO REMEDIAL OR ADDITIONAL COMPENSATION WILL BE ALLOWED. 2. ALL WORK SHALL CONFORM TO ALL NATIONAL BUILDING AND ELECTRICAL CODES EXCEPT WHEN THE STATE D.O.T. AND /OR THE CITY STANDARDS SUPERSEDE. 3 v f E � F4 EXISTING CITY CABINET AND POWER 7 CC F F — A -- — POWER POLE P1w '3 14 I SANDY LAKE RD _ w w w w w w f GF+� �7 I I 1 12 13 12 REDFLEX CABINET - - - - -- ,.d mLa A, COMM. PEDESTAL 12 —COMM. VAULT ll I - - I � j I III z J _ T, FIC — VIDEO VEHICLE DETECTION CAMERA ON POLE. MOUNT CAMERA 3D' UP. ROUTE COAXIAL CABLE BACK TO RTS CABINET. PLATE FLASH ON POLE W /250 WATT FLASH, MOUNTED 10' UP, 2 7 810111217 REDFLEX CAMERA ENCLOSURE W/250 WATT SCENE FLASH COP— MASL -01 On) 9111216 CONDUCTORS POLE SCHEDULE POWER CABINET NO. TYPE CONDUITS NEW/ EXISTING �1 REDFLEX 10' N E.O.P. = EDGE OF PAVEMENT REDFLEX 30' N LzEL TERMINATION RELEASED FOR SOURCE AWG# 3 4 s a D 10 11 z 4 1 1 r POLE 1 CATS 3 3 3 3 CONSTRUCTION REDFLEX CABINET MAY 14, 2007 POLE 1 TSP #14 2 2 POLE 2 POLE 2 VIDEO LOOP DETECTION CCTV 1 1 REDFLEX CABINET RTS POWER PEDESTAL (120V) #8 2 2 2 3 REDFLEX CABINET TRAFFIC SIGNAL RED PHASE (5 OR 7 CABLE CONDUCTOR) #14 1 1 1 1 CABINET POWER CIRCUIT 1 (REDFLEX CABINET) #10 2 2 2 2 POLE 1 POWER CIRCUIT 2 (REDFLEX CABINET) # 10 2 2 POLE 2 SOLID BARE BOND #8 1 1 1 1 ALL REDFLEX EQUIPMENT TRACE WIRE (FOR LOCATING) W10 1 1 1 1 1 ALL REDFLEX EQUIPMENT TELCO POINT OF SERVICE CATS 1 1 REDFLEX CABINET TOTAL NEW CONDUCTORS 12 8 11 11 3 3 1 3 2 CONDUIT SIZE (INCHES) 3 2 3 3 2 2 2 2 2 CONDUIT LENGTH (- FEET). 3 45 4 23 103120 2 32 15 NEW /EXISTING CONDUIT N N N N E E E E N ,.d mLa A, COMM. PEDESTAL 12 —COMM. VAULT ll I - - I � j I III z J _ T, FIC — VIDEO VEHICLE DETECTION CAMERA ON POLE. MOUNT CAMERA 3D' UP. ROUTE COAXIAL CABLE BACK TO RTS CABINET. PLATE FLASH ON POLE W /250 WATT FLASH, MOUNTED 10' UP, 2 7 810111217 REDFLEX CAMERA ENCLOSURE W/250 WATT SCENE FLASH COP— MASL -01 On) 9111216 ® TRAFFIC CONTROL CABINET POLE SCHEDULE POWER CABINET NO. TYPE HEIGHT NEW/ EXISTING �1 REDFLEX 10' N E.O.P. = EDGE OF PAVEMENT REDFLEX 30' N ® TRAFFIC CONTROL CABINET o POWER CABINET reTS REDFLEX CONTROL CABINET TSP - TWISTED SHIELDED PAIR CAMERA W /FLASH LED - LIGHT EMITTING DIODE VIDEO DET. CAMERA & PLATE FLASH o PULL /JUNCTION BOX 10' 0 20' ® ABBREVIATIONS CATS - CATEGORY FIVE CABLE DLC - DETECTOR LOOP CABLE (SHIELDED) SCALE: 1 ° =20' TSP - TWISTED SHIELDED PAIR LED - LIGHT EMITTING DIODE R/W - RIGHT OF WAY E.O.P. = EDGE OF PAVEMENT SEAL �'�VSUNS BELAY " " " ° °" JL REVIEWED BY CITY STAFF APPROVED By CITY OF: ������� PAT E SCHE REDFLEX PER INITIAL DESCRIPTION DESIGNED BY: DEPARTMENT INITIAL DATE (WMMDD) 1 D 070330 JL INITIAL RELEASE N B B PUBLIC WORKS (OPER.) RED LAG HT PHOTO E N FORCEM ENT DRAWING No. 1.1 070426 ILEUM uPTD NOTES 5 AND 14 ADDED UTILITIES. TRAFFIC SYSTEMS CHECKED RY_ PUOLi� WORKS (ENV.) PUBLIC WORKS DIRECTOR T CITY ENGINEER DATE 1.2 070526 JPM ' HANGED LOWE R POLE LocnnoN EB 15020 N. 74TH STREET EeoMMENDeO ev: - TITLE: 3027 SB SCOTTSDALE, AZ 85260 R eUBLC WORKS (WATER) RECOMMENDED BY: RECOMMENDED BY: WB PH: 480 607 0705 P WORKS (HERE.) MACARTHUR BLVD AT SANDY LAKE RD -103 DEPUTY CITY ENGINEEF DEVELOPMENT SERVICES CONSTRUCTION NOTES ❑i INSTALL FOUNDATION AND REDFLEX CONTROL CABINET, 5/8 "x15' GROUND ROD AND BOND TO CABINET AND POLE BASES WITH #8 BARE Cu. SEE CABINET FOUNDATION DETAIL. 0 CONTRACTOR SHALL TERMINATE AND LAND ALL POWER CIRCUITS INTO REDFLEX CABINET, O INSTALL INURE FUSE HOLDER ON RED PHASE CONDUCTOR WITH 5 AMP FUSE INSIDE REDFLEX CABINET TO PROTECT CITY TRAFFIC CABINET. ® INSTALL A 40 AMP CIRCUIT BREAKER INTO EXISTING POWER PANEL FOR 120V SUPPLY TO REDFLEX CABINET.. 0 TERMINATE #14 WIRE TO RED PHASE AND NEUTRAL INSIDE CITY TRAFFIC CABINET_ SEE CONDUCTOR SCHEDULE FOR APPROACHES. (NOTE: MUST BE DONE MONDAY- THURSDAY. NOTIFY THE TRAFFIC OPERATIONS DEPARTMENT OF THE CITY 24 HOURS BEFORE CONNECTION) © INSTALL JUNCTION BOX OF THE SIZE AND TYPE PER STANDARDS OF THE CITY - VERIFY BEFORE INSTALLATION, 0 INSTALL VIDEO VEHICLE DETECTION CAMERA ON 30' POLE. ROUTE CCTV CABLE BACK TO RTS CABINET. ® INSTALL FOUNDATION POLE AND GROUND ROD FOR REDFLEX EQUIPMENT. SEE DRAWING FOR LOCATION. SEE POLE DETAIL. ❑0 INSTALL CAMERA AND FLASH ENCLOSURE ON REDFLEX POLE; AIM AT MONITORED APPROACHES. INCLUDE 3 #14 AWO CONDUCTOR CABLES FROM CAMERA ENCLOSURE TO FLASH. 10INSTALL A 250 WATT FLASH UNIT ON REDFLEX POLE, AIM AT MONITORED APPROACHS. 11 CONNECT POLE TO SOLID BARE BOND GROUND AND GROUNDING ROD IN POLE FOUNDATION AND TO SYSTEM GROUND BONDED BACK AT THE REDFLEX CABINET. H TRACER WIRE TO BE RUN THROUGH ALL CONDUIT FROM THE REDFLEX CABINET TO ALL REDFLEX EQUIPMENT. 13 CONDUIT TO BE BORED UNDER ROADWAY TO MIN. STANDARD COVER DEPTH REQUIRED BY THE CITY (24" MINIMUM). ® EXISTING SIGNAL HEADS HAVE LED'S INSTALLED. IF NEEDED ADJUST SIGNAL HEAD SO IT IS VISIBLE TO THE REDFLEX CAMERA, MUST BE DONE WITH CITY SUPERVISION. i5 REFRESH STRIPING (VIOLATION LINE AND LANES ETC) AS NEEDED AT THE MONITORED APPROACHES. 1D TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #1 (HOT AND NEUTRAL), T7 TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #2 (HOT AND NEUTRAL). MUST VERIFY EXISTING UTIUTY INFO AND LOCATION GENERAL NOTES 1. ALL EXISTING UTILITIES SHOWN WITHIN THE PLANS ARE PROVIDED BY THE BEST AVAILABLE INFORMATION PROVIDED BY COOPERATING UTILITY COMPANIES. NEITHER REDFLEX NOR THE CITY A55UME RESPONSIBILITY AS TO THE PRECISE LOCATION OR ACCURACY OF SHOWN UTILITIES. THE CONTRACTOR SHALL PROPERLY FIELD VERIFY UTILITY LOCATIONS AND SHALL PROPERLY PROTECT, MAINTAIN AND /OR REPAIR ANY DAMAGE OF ALL KNOWN AND ANY EXPOSED UNKNOWN UTILITIES SHOWN WITHIN THE PLANS. REDFLEX AND THE CITY ASSUME NO LIABILITY RESULTING IN POSSIBLE DEFICIENCIES IN UTILITY LOCATIONS AND NO REMEDIAL OR ADDITIONAL COMPENSATION WILL BE ALLOWED. 2. ALL WORK SHALL CONFORM TO ALL NATIONAL BUILDING AND ELECTRICAL CODES EXCEPT WHEN THE STATE D.O.T. AND /OR THE CITY STANDARDS SUPERSEDE. y � POLE 2 VIDEO LOOP DETECTION POWER PEDESTAL (120V) TRAFFIC SIGNAL RED PHASE (5 OR 7 CABLE CONDUCTOR) POWER CIRCUIT 1 (REDFLEX CABINET) POWER CIRCUIT 2 (REDFLEX CABINET) SOLID BARE BOND TRACE WIRE (FOR LOCATING) TELCO POINT OF SERVICE TOTAL NEW CONDUCTORS CONDUIT SIZE (INCHES) CONDUIT LENGTH (- FEET) C C� 10' 0 20' SCALE: 1"-20' CONDUCTORS RELEASED FO R SOURCE AWG# CONSTRUCTION POLE 1 CATS MAY 14, 2007 POLE 1 TSP #14 14 10 10 9 9 4 1 4 2 3 3 3 2 2 2 -- 2 10 18 30 33 5 9 4 19 18 N E E I N TY 4 14 p4 - - E BELT LINE RD. I � \ RTS VIOLATION LINE 6 ❑ 2 K J FEE i1 F— Q Q (n Z_� , h '7 Ati I r 1 w 4 w Q w J w a NEW/ ESTING O1 L I 8 PO WED ON POLE - — �- IsTINC CITY CABINET [AT 4 5 AND POWER 9. REDFLEX CABINET VIDEO VEHICLE DETECTION CAMERA ON POLE. MOUNT CAMERA 3D' UP. ROUTE COAXIAL CABLE BACK To RTS. CABINET. PLATE FLASH ON POLE W/250 WATT FLASH, MOUNTED 10' UP. ( D 7 E8 12 COMM PEDESTAL REDFLEX CAMERA ENCLOSURE W /250 WATT SCENE FLASH COP - MABL -01 ( U81 9 011 CONDUITS 4 5 6 C 7 8 9 3 3 3 2 2 1 #8 2 2 #14 1 #10 2 2 2 2 2 #10 2 2 2 #8 T #10 TERMINATION REDFLEX CABINET POLE 2 REDFLEX CABINET POLE 1 POLE 2 ALL REDFLEX EQUIPMENT ALL REDFLEX EQUIPMENT POLE SCHEDULE N0. TYPE HEIGHT NEW/ ESTING O1 REDFLEX 10' N O2 REDFLEX 30' N ® TRAFFIC CONTROL CABINET A POWER CABINET RTS REDFLEX CONTROL CABINET CAMERA W /FLASH VIDEO DET. CAMERA & PLATE FLASH a PULL /JUNCTION BOX ABBREVIATIONS CAT5 - CATEGORY FIVE CABLE DLC - DETECTOR LOOP CABLE (SHIELDED) TSP - TWISTED SHIELDED PAIR LED - LIGHT EMITTING DIODE R/W - RIGHT OF WAY E.O.P. = EDGE OF PAVEMENT SEAL �'�VSUNS RELAY " " " °° "FPM REVIEWED BY CITY STAFF APPROVED By CITY OF: ������� DATE SCHE REDFLEX PER INITIAL DESCRIPTION DESIGNED BYT DEPARTMENT INITIAL DATE (WMMDD) tD 570492 JL JM INITIAL RELEASE NB JB PUBLIC WORKS (OPEX) REDLIGHT PHOTO ENFORCEMENT DRAWING NP. 1.1 070426 JL JM JPTD NOTES 5 AND 14 ADDED UTILITIES. TRAFFIC SYSTEMS CHECKED By PUBLIC WORKS (ENV.) PUBLIC WORKS DIRECTOR T CITY ENGINEER DATE L2 070504 A TELCO WAS LOCATED TO THE EAST OF THE SCENE CAMERA E B _ TITLE: Q 1.3 070525 JPM CHANGED POWER POLE LOCATION 15020 N. 74TH STREET PUBLIC WORKS (WATER) RECOMMENDED BY; RECOMMENDED BY: 3027 sB SG°ILF 480 60 Z o 0 RED OMMENDED BY: PUBLIC WORKS (TRAP.) MACARTHUR BLVD AT BELT LINE RD -104 p W # FIRE DEPT. DEPDTV CITY ENGINEER DEVELOPMENT SERVICES CONSTRUCTION NOTES ❑i INSTALL FOUNDATION AND REDFLEX CONTROL CABINET, 5/8 "x15' GROUND ROD AND BOND TO CABINET AND POLE BASES WITH #8 BARE Cu. SEE CABINET FOUNDATION DETAIL. 0 CONTRACTOR SHALL TERMINATE AND LAND ALL POWER CIRCUITS INTO REDFLEX CABINET. ❑3 INSTALL INURE FUSE HOLDER ON RED PHASE CONDUCTOR WITH 5 AMP FUSE INSIDE REDFLEX CABINET TO PROTECT CITY TRAFFIC CABINET. ® INSTALL A 40 AMP CIRCUIT BREAKER INTO EXISTING POWER PANEL FOR 120V SUPPLY TO REDFLEX CABINET.." ❑5 TERMINATE #14 WIRE 70 RED PHASE AND NEUTRAL INSIDE CITY TRAFFIC CABINET_ SEE CONDUCTOR SCHEDULE FOR APPROACHES. (NOTE: MUST BE DONE MONDAY— THURSDAY. NOTIFY CONDUCTORS SOURCE AWG# CONDUITS TERMINATION 1 2 3 4 5 6 7 8 9 10 11 2 1 4 1 THE TRAFFIC OPERATIONS DEPARTMENT OF THE CITY 24 HOURS BEFORE CONNECTION) FATE © INSTALL JUNCTION BOX OF THE SIZE AND TYPE PER STANDARDS OF THE CITY — VERIFY 3 BEFORE INSTALLATION. TRAFFIC SIGNAL RED ❑7 INSTALL VIDEO VEHICLE DETECTION CAMERA ON 30' POLE. ROUTE CCTV CABLE BACK TO RTS CABINET. O1 PC INSTALL FOUNDATION POLE AND GROUND ROD FOR REDFLEX EQUIPMENT. SEE DRAWING 10' FOR LOCATION, SEE POLE DETAIL. Q ❑9 INSTALL CAMERA AND FLASH ENCLOSURE ON REDFLEX POLE; AIM AT MONITORED #14 APPROACHES. INCLUDE 3 #14 AWG CONDUCTOR CABLES FROM CAMERA ENCLOSURE TO [� POLE 1 TSP FLASH. 1 — LIGHT EMITTING DIODE 2 DINSTALL A 250 WATT FLASH UNIT ON REDFLEX POLE, AIM AT MONITORED APPROACHS. Q 2 2 2 OF CONNECT POLE TO SOLID BARE BOND GROUND AND GROUNDING ROD IN POLE FOUNDATION AND TO SYSTEM GROUND BONDED BACK AT THE REDFLEX CABINET. Z POWER CIRCUIT 2 (REDFLEX CABINET) 0 2 12 TRACER WIRE TO BE RUN THROUGH ALL CONDUIT FROM THE REDFLEX CABINET TO ALL 'r POLE 2 REDFLEX EQUIPMENT. 1 1Y1„ LJ L SOLID BARE BOND 15 CONDUIT TO BE BORED UNDER ROADWAY TO MIN. STANDARD COVER DEPTH REQUIRED BY 0 1 THE CITY (24" MINIMUM). 1 14 EXISTING SIGNAL HEADS HAVE LED'S INSTALLED. IF NEEDED ADJUST SIGNAL HEAD SO IT IS VISIBLE TO THE REDFLEX CAMERA, MUST BE DONE WITH CITY SUPERVISION, 15 REFRESH STRIPING (VIOLATION LINE AND LANES ETC) AS NEEDED AT THE MONITORED W10 APPROACHES. 1 i6 TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #1 (HOT AND NEUTRAL). T7 TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #2 (HOT AND NEUTRAL). TELCO POINT OF SERVICE MUST VERILY EXISTING UTILITY INFO AND LOCATION GENERAL NOTES 1. ALL EXISTING UTILITIES SHOWN WITHIN THE PLANS ARE PROVIDED BY THE BEST AVAILABLE INFORMATION PROVIDED BY COOPERATING UTILITY COMPANIES. NEITHER REDFLEX NOR THE CITY A55UME RESPONSIBILITY AS TO THE PRECISE LOCATION OR ACCURACY OF SHOWN UTILITIES. THE CONTRACTOR SHALL PROPERLY FIELD VERIFY UTILITY LOCATIONS AND SHALL PROPERLY PROTECT, MAINTAIN AND /OR REPAIR ANY DAMAGE OF ALL KNOWN AND ANY EXPOSED UNKNOWN UTILITIES SHOWN WITHIN THE PLANS. REDFLEX AND THE CITY ASSUME NO LIABILITY RESULTING IN POSSIBLE DEFICIENCIES IN UTILITY LOCATIONS AND NO REMEDIAL OR ADDITIONAL COMPENSATION WILL BE ALLOWED. 2. ALL WORK SHALL CONFORM TO ALL NATIONAL BUILDING AND ELECTRICAL CODES EXCEPT WHEN THE STATE D.O.T. AND /OR THE CITY STANDARDS SUPERSEDE. 'r� v �� COMM PEDESTAL 12 " CONDUCTORS SOURCE AWG# CONDUITS TERMINATION 1 2 3 4 5 6 7 8 9 10 11 2 1 4 1 POLE 1 FATE 3 3 3 TRAFFIC SIGNAL RED CAMERA W /FLASH EXISTING O1 REDFLEX 10' N Q PHASE (5 OR 7 CABLE CONDUCTOR) #14 REDFLEX CABINET POLE 1 TSP #14 1 — LIGHT EMITTING DIODE 2 # iD 2 2 2 POWER CIRCUIT 2 (REDFLEX CABINET) # 10 2 2 POLE 2 POLE 2 VIDEO LOOP 1 1Y1„ SOLID BARE BOND #8 1 1 1 TRACE WIRE (FOR LOCATING) W10 1 1 REDFLEX [ 4 1 51 EXISTING CITY CABINET 7 AND POWER POWER ON POLE — I I V I REDFLEX CAMERA ENCLOSURE W/250 WATT SCENE FLASH COP— SLDT -01 SANDY LAKE RD 0' 0 20' SCALE: 1 " =20' REDFLEX CABINET POLE 1 POLE 2 ALL REDFLEX EQUIPMENT ALL REDFLEX EQUIPMENT RELEASED FOR CONSTRUCTION MAY 14, 2007 I:IIY PUWER PEDESTAL (120V) # 2 NO. 2 3 NEW/ TRAFFIC SIGNAL RED CAMERA W /FLASH EXISTING O1 REDFLEX 10' N Q PHASE (5 OR 7 CABLE CONDUCTOR) #14 1 TSP 1 1 — LIGHT EMITTING DIODE POWER CIRCUIT 1 (REDFLEX CABINET) # iD 2 2 2 POWER CIRCUIT 2 (REDFLEX CABINET) # 10 2 2 SOLID BARE BOND #8 1 1 1 TRACE WIRE (FOR LOCATING) W10 1 1 1 1 1 1 TELCO POINT OF SERVICE CATS 1 1 1 TOTAL NEW CONDUCTORS 14 10 9 4 1 3 2 2 CONDUIT SIZE (INCHES) 3 2 2 2 2 2 CONDUIT LENGTH (- FEET). 4 46 41 8 3 16 158 9 NEW /EXISTING CONDUIT N N N N E E N N REDFLEX CAMERA ENCLOSURE W/250 WATT SCENE FLASH COP— SLDT -01 SANDY LAKE RD 0' 0 20' SCALE: 1 " =20' REDFLEX CABINET POLE 1 POLE 2 ALL REDFLEX EQUIPMENT ALL REDFLEX EQUIPMENT RELEASED FOR CONSTRUCTION MAY 14, 2007 SEAL HEVISIUNS RELAY " " " °° "FPM REVIEWED BY CITY STAFF APPROVED By CITY OF: ������� DATE SCHE REDFLEX PER INITIAL DESCRIPTION DESIGNED B'TT DEPARTMENT INITIAL DATE (WMMDD) 0 070402 dL JM INITIAL RELEASE NB JB PUBLIC WORKS (OPER.) REDLIGHT PHOTO ENFORCEMENT DRAWING NO, 1.1 070427 dL JM uPTD NOTES 5 AND 14 ADDED UTILITIES. TRAFFIC SYSTEMS CHECKED RY. PUBLIC WORKS DIRECTOR T CITY ENGINEER DATE L2 070504 A TELCO POLE WAS 150 FROM TRAFFIC CABINET BB PUBLC WORKS (ENV.) TITLE: O 13 D70525 JPM RELOCATED RTS EOUIP. AND POWER POLE LOCATIONS 15020 N. , 74TH STREET 027 sB SC °H7 480L Z o 0 BUBLC WORKS (WATER) 5 G° RECOMMENDED BY, PUBLIC WORKS (TRAP.) RECOMMENDED BY: RECOMMENDED BY: 3 DENTON TAP RD AT SANDY LAKE RD -105 p W # FIRE DEPT DEPUTY CITY ENGINEER I DEVELOPMENT SERVICES 14 14 LEGEND POLE SCHEDULE TRAFFIC CONTROL CABINET NO. APE HEIGHT NEW/ w CAMERA W /FLASH EXISTING O1 REDFLEX 10' N Q REDFLEX 30' N SEAL HEVISIUNS RELAY " " " °° "FPM REVIEWED BY CITY STAFF APPROVED By CITY OF: ������� DATE SCHE REDFLEX PER INITIAL DESCRIPTION DESIGNED B'TT DEPARTMENT INITIAL DATE (WMMDD) 0 070402 dL JM INITIAL RELEASE NB JB PUBLIC WORKS (OPER.) REDLIGHT PHOTO ENFORCEMENT DRAWING NO, 1.1 070427 dL JM uPTD NOTES 5 AND 14 ADDED UTILITIES. TRAFFIC SYSTEMS CHECKED RY. PUBLIC WORKS DIRECTOR T CITY ENGINEER DATE L2 070504 A TELCO POLE WAS 150 FROM TRAFFIC CABINET BB PUBLC WORKS (ENV.) TITLE: O 13 D70525 JPM RELOCATED RTS EOUIP. AND POWER POLE LOCATIONS 15020 N. , 74TH STREET 027 sB SC °H7 480L Z o 0 BUBLC WORKS (WATER) 5 G° RECOMMENDED BY, PUBLIC WORKS (TRAP.) RECOMMENDED BY: RECOMMENDED BY: 3 DENTON TAP RD AT SANDY LAKE RD -105 p W # FIRE DEPT DEPUTY CITY ENGINEER I DEVELOPMENT SERVICES 14 14 LEGEND ® TRAFFIC CONTROL CABINET A POWER CABINET 1771 REDFLEX CONTROL CABINET w CAMERA W /FLASH VIDEO GET. CAMERA & PLATE FLASH 0 PULL /JUNCTION BOX ABBREVIATIONS CAT5 — CATEGORY FIVE CABLE DLC — DETECTOR LOOP CABLE (SHIELDED) TSP — TWISTED SHIELDED PAIR LED — LIGHT EMITTING DIODE R/W — RIGHT OF WAY E.O.P. = EDGE OF PAVEMENT SEAL HEVISIUNS RELAY " " " °° "FPM REVIEWED BY CITY STAFF APPROVED By CITY OF: ������� DATE SCHE REDFLEX PER INITIAL DESCRIPTION DESIGNED B'TT DEPARTMENT INITIAL DATE (WMMDD) 0 070402 dL JM INITIAL RELEASE NB JB PUBLIC WORKS (OPER.) REDLIGHT PHOTO ENFORCEMENT DRAWING NO, 1.1 070427 dL JM uPTD NOTES 5 AND 14 ADDED UTILITIES. TRAFFIC SYSTEMS CHECKED RY. PUBLIC WORKS DIRECTOR T CITY ENGINEER DATE L2 070504 A TELCO POLE WAS 150 FROM TRAFFIC CABINET BB PUBLC WORKS (ENV.) TITLE: O 13 D70525 JPM RELOCATED RTS EOUIP. AND POWER POLE LOCATIONS 15020 N. , 74TH STREET 027 sB SC °H7 480L Z o 0 BUBLC WORKS (WATER) 5 G° RECOMMENDED BY, PUBLIC WORKS (TRAP.) RECOMMENDED BY: RECOMMENDED BY: 3 DENTON TAP RD AT SANDY LAKE RD -105 p W # FIRE DEPT DEPUTY CITY ENGINEER I DEVELOPMENT SERVICES 14 14