Loading...
MA1001-LR100704RLLIfII'ICE 6 GEOTECHIYICflL GROUP Consulting Engineering " Geotechnical Engineering ' Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C10 -0535 Date Sampled: 06/24/2010 Report Date: 07/04/2010 Previously Reported: 06/25/2010 Sampled By: Gatton, Tim Project: Denton Tap & Sandy Lake Brick Paver Replacement C.I.P Project By Order Of: Rick O'Dell MA 10 -01 Location: Denton Tap & Sandy Lake Intersection Order Number: Vendor #9176 Client: The City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 86823 Test Method: See Below TEST RESULTS Report No: 86823 Page 1 of 2 Set: 1 of 2 Material: Concrete Number of Specimens: 4 Location: Northbound Main Lanes East side of Denton Tap and Sandy Lake intersection, 8' west x 4' south of southeast corner Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nbr (days) (in) (in Z) (Ibs) Break Type Loc (PSI) (PSI) Comments A 1 6.00 28.27 76,935 Type 4 Lab 2,720 2,720 B 2 6.00 28.27 100,250 Type 4 Lab 3,550 3,550 C 7 6.00 28.27 111,650 Type 4 Lab 3,950 3,950 D 28 6.00 28.27 Lab Hl'�71 D M E] Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 4,000 psi @ 28 days Date Received: 06/25/2010 Slump: 3.0 Inches Transported By: LMC Curing Method: Standard Air Content: 4.1 % Source /Sampled At: Truck / Center Time Sampled: 7:44 am Plant: 6 Temp.: Ambient: 87 °F Mix: 92 °F Mix Code: 1701 Truck/Ticket No: 3012 / 6372799 Quantity Represented: 15 cu. yds. at 20 cu. yds. placed of a 150 cu. yd. total placement Remarks: 20 yard truck rejected by contractor for wrong color of concrete. 30 yard truck is now 20 yards. Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Charge: The City of Coppell Attn: George S. Marshall, P.E. Orig: The City of Coppell (Coppell, TX) Attn: George S. Marshall P.E. Respectfully Submitted, (1 eccopy) Alliance Geotechnical Group 1 -ec Jim Bowman Construction Company, L.P Attn: Lee Halencak, P.E. J�/ 1 -ec The City of Coppell Attn: Rick O'Dell r !f �V -.-.... Robert P. Nance, Sr. Project Manager RLL.IAMCE G cEoTecrirncAL GROW Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C10 -0535 Date Sampled: 06/24/2010 Report Date: 07/04/2010 Previously Reported: 06/25/2010 Sampled By: Gatton, Tim Project: Denton Tap & Sandy Lake Brick Paver Replacement C.I.P Project By Order Of: Rick O'Dell MA 10 -01 Location: Denton Tap & Sandy Lake Intersection Order Number: Vendor #9176 Client: The City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 86823 Test Method: See Below TEST RESULTS Report No: 86823 Page 2 of 2 Set: 2 of 2 Material: Concrete Number of Specimens: 4 Location: East side of Denton Tap and Sandy Lake intersection northbound Denton Tap Main Lanes D 28 6.00 28.27 �rl Type 1 Specification: 4,000 psi @ 28 days Date Received: 06/25/2010 Curing Method: Standard Time Sampled: 10:22 am Temp.: Ambient: 97 °F Mix: 92 °F Lab RD19 E Maximum Type 5 Type 6 Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nbr (days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) Comments A 1 6.00 28.27 71,500 Type 3 Lab 2,530 2,530 B 2 6.00 28.27 95,610 Type 4 Lab 3,380 3,380 C 7 6.00 28.27 110,250 Type 4 Lab 3,900 3,900 D 28 6.00 28.27 �rl Type 1 Specification: 4,000 psi @ 28 days Date Received: 06/25/2010 Curing Method: Standard Time Sampled: 10:22 am Temp.: Ambient: 97 °F Mix: 92 °F Lab RD19 E Type 2 Type 3 Type 4 Type 5 Type 6 Slump: 3.5 Inches Transported By: LMC Air Content: 3.7% Source /Sampled At: Truck / Center Plant: 3 Mix Code: 1701 Truck/Ticket No: 9141 / 3278346 Quantity Represented: 125 cu. yds. at 130 cu. yds. placed of a 150 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Charge: The City of Coppell Attn: George S. Marshall, P.E. Orig: The City of Coppell (Coppell, TX) Attn: George S. Marshall, P.E. (1 -ec copy) 1 -ec Jim Bowman Construction Company, L.P Attn: Lee Halencak, P.E. 1 -ec The City of Coppell Attn: Rick O'Dell Respectfully Submitted, Alliance Geotechnical Group Robert P. Nance, Sr. Project Manager