Acct ID: 1770 File No: C10 -0631 Date Sampled: 07/08/2010
Report Date: 07/14/2010 Sampled By: Jon Schuler
Project: Bethel Road Paving & Utility Improvements By Order Of: Larry Davis
Location: Drilled Bridge Pier Observation Order Number: Vendor #9176
Contractor: JRJ Paving
Client: The City of Coppell
REPORT: Drilled Bridge Pier Observation LAB NO: 87379
TEST RESULTS Report No: 87379
Page 1 of 1
As requested, a representative of Alliance Geotechnical Group went to the project site to observe drilled pier
operations. Only one pier was worked on but not completed. DS3 -3 pier was initially drilled and poured in the wrong
location. Redrilling with an oversized auger was done through the concrete and into the bearing stratum.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -ec copy)
1 -ec Freese & Nichols, Inc. Attn: B. Caleb Thornhill, P.E.
1 -ec JRJ Paving Attn: Mr. Marty Murphy
1 -ec The City of Coppell Attn: Mr. Larry Davis
Respectfully Submitted,
Alliance Geotechnical Group
Robert P. Nance, Sr. Project Manager
RuUAncE
G cEorEcnrocAL
Cffi UP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID:
1770 File No: C10 -0631
Date Sampled: 07/07/2010
Report Date: 07/14/2010
Sampled By: Jon Schuler
Project:
Bethel Road Paving & Utility Improvements
By Order Of: Larry Davis
Location:
Bridge Piers
Order Number: Vendor #9176
Contractor:
JRJ Paving
Client:
The City of Coppell
REPORT:
Soils Attachment
LAB NO: 87260 -1
Test Method: See Below
TEST RESULTS Report No: 87260 -1
Page 1 of 1
Remarks: See attached report.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -ec copy)
1 -ec Freese & Nichols, Inc. Attn: B. Caleb Thornhill, P.E.
1 -ec JRJ Paving Attn: Mr. Marty Murphy
1 -ec The City of Coppell Attn: Mr. Larry Davis
Respectfully Submitted,
Alliance Geotechnical Group
Y 4 . 9--
Robert P. Nance, Sr. Project Manager
ALLIANCE GEOTECHNICAL GROUP
CONSULTING ENGINEERING * GEOTECHNICAL ENGINEERING * CONSTRUCTION MATERIALS
10610 Newkirk Street, Suite 202, Dallas, Texas 75220 Phone:972- 444 -8889 Fax: 972 - 444 -8893
DRILLED PIER INSPECTION REPORT
CLIENT: City of Coppell REPORT DISTRIBUTION:
PROJECT: Bethel Road II City of Coppell - Keith Marvin, P.E.
AGG REPORT #: C10- 0631 - 87260 -1 City of Coppell - Larry Davis
REPORT DATE: 7/9/2010 Freese & Nichols - B. Caleb Thornill, P.E.
INSPECTOR /DATE: 7/7/2010 JRJ Paving - Marty Murphy
DRILLING COMPANY: ATS
AGG Pier No.
7
6
10
9
5
Pier Location (grid lines)
DS 2 -3
DS 2 -2
DS 3 -3
DS 3 -2
DS 2 -1
Design Shaft Diameter (inches)
30.0 inches
30.0 inches
30.0 inches
30.0 inches
30.0 inches
Design Penetration (feet)
8.0 feet
8.0 feet
8.0 feet
8.0 feet
8.0 feet
Design Elevation of Bottom of Pier (feet)
466.0 feet
466.0 feet
466.0 feet
466.0 feet
466.0 feet
Ground Elevation (feet)
480.15 feet
481.93 feet
483.30 feet
482.15 feet
479.19 feet
Actual Shaft Diameter (inches)
30.0 inches
30.0 inches
30.0 inches
30.0 inches
30.0 inches
Depth to Bearing Stratum - Unweathered hard
Gray Limestone (feet)
3.60 feet
6.00 feet
5.75 feet
4.75 feet
5.00 feet
Required Pier Depth (using des. pen.) (J +A)
11.60 feet
14.00 feet
13.75 feet
12.75 feet
13.00 feet
Required Pier Depth (using des. pen.) (I +H)
14.15 feet
15.93 feet
17.30 feet
16.15 feet
13.19 feet
Actual Pier Depth (= or > B, Z and D)
14.20 feet
16.10 feet
17.70 feet
16.20 feet
13.20 feet
Actual Pier Penetration
10.60 feet
10.10 feet
11.95 feet
11.45 feet
8.20 feet
Pier Location within Tolerance
yes
yes
yes
yes
yes
Pier Plumb within Specifications
yes
yes
yes
yes
yes
Casing Required
no
no
no
no
no
Length of Casing
n.a.
n.a.
n.a.
n.a.
n.a.
Depth to Top of Casing (" - " (minus) if above
ground)
na
na
na
na
na
Depth to Bottom of Casing (E + F)
na
na
na
na
na
Depth Required Due to Casing (G + A)
na
na
na
na
na
Water Present in Hole at Concrete Pour
no
no
no
no
no
Pier Bottom Clean
yes
yes
yes
yes
yes
Vertical Bars (number & Size)
849's
849's
849's
849's
849's
Horizontal Ties (Size & Spacing)
#3 spiral
#3 spiral
#3 spiral
#3 spiral
error
Steel Cage Diameter
24.0 inches
24.0 inches
24.0 inches
24.0 inches
24.0 inches
Length of Steel Cage
9.0 feet
9.0 feet
9.0 feet
9.0 feet
9.0 feet
Concrete Placed in Center of Pier Hole with a
Hopper or Inverted Chute
yes
yes
yes
yes
yes
KtMAKK
ALLIANCE GEOTECHNICAL GROUP
ALLIANCE GEOTECHNICAL GROUP
CONSULTING ENGINEERING * GEOTECHNICAL ENGINEERING * CONSTRUCTION MATERIALS
10610 Newkirk Street, Suite 202, Dallas, Texas 75220 Phone:972- 444 -8889 Fax: 972 - 444 -8893
DRILLED PIER INSPECTION REPORT
CLIENT: City of Coppell
PROJECT: Bethel Road II
AGG REPORT #: C10- 0631 - 87260 -1
REPORT DATE: 7/9/2010
INSPECTOR /DATE: 7/7/2010
REPORT DISTRIBUTION:
City of Coppell - Keith Marvin, P.E.
City of Coppell - Larry Davis
Freese & Nichols - B. Caleb Thornill, P.E.
JR.] Pavinn - Marty Murnhv
AGG Pier No.
Pier Location (grid lines)
DS 3 -1
Design Shaft Diameter (inches)
30.0 inches
Design Penetration (feet)
8.0 feet
Design Elevation of Bottom of Pier (feet)
466.0 feet
Ground Elevation (feet)
481.77 feet
Actual Shaft Diameter (inches)
30.0 inches
Depth to Bearing Stratum - Unweathered hard
Gray Limestone (feet)
1.00 feet
Required Pier Depth (using des. pen.) (J +A)
9.00 feet
Required Pier Depth (using des. pen.) (I +H)
15.77 feet
Actual Pier Depth (= or > B, Z and D)
16.70 feet
Actual Pier Penetration
15.70 feet
Pier Location within Tolerance
yes
Pier Plumb within Specifications
yes
Casing Required
no
Length of Casing
na
Depth to Top of Casing (" - " (minus) if above
ground)
na
Depth to Bottom of Casing (E + F)
na
Depth Required Due to Casing (G + A)
na
Water Present in Hole at Concrete Pour
no
Pier Bottom Clean
yes
Vertical Bars (number & Size)
849's
Horizontal Ties (Size & Spacing)
#3 spiral
Steel Cage Diameter
24.0 inches
Length of Steel Cage
9.0 feet
Concrete Placed in Center of Pier Hole with a
Hopper or Inverted Chute
yes
KtMAKKJ:
ALLIANCE GEOTECHNICAL GROUP
R1-UAncE
GEOTECHnPCRL
'GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID:
1770 File No: C10 -0631
Date Sampled: 07/06/2010
Report Date: 07/14/2010
Sampled By:
Schuler, Jon
Project:
Bethel Road Paving & Utility Improvements
By Order Of:
Larry Davis
Location:
10' Recess Curb Inlet Walls & Bottom on Storm Drain Line "D ",
Order Number:
Vendor #9176
Air Content: 2.8%
Station 3 +03.65
Time Sampled:
1:30 pm
Contractor:
JRJ Paving
Number of
92 °F Mix: 94 °F
Client:
The City of Coppell
Specimens:
4
REPORT:
REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
LAB NO:
87234
Material:
CONCRETE
Test Method:
See Below
TEST RESULTS Report No: 87234
Page 1 of 1
Spec
Age Tested
Nbr
(days)
A
7
B
28
C
28
D
Transported By: Southern Star
Diameter Area
(in)
(in')
6.00
28.27
6.00
28.27
6.00
28.27
Maximum
Load
(lbs) Break Type
103,570 Type 3
millmiul����
Average
Strength
(PSI) Comments
3,660
HOLD (see remarks) -
Compressive
Cure
Strength
Loc
(PSI)
Lab
3,660
Lab
07/07/2010
Lab
Transported By: Southern Star
millmiul����
Average
Strength
(PSI) Comments
3,660
HOLD (see remarks) -
Quantity Represented: 5 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -ec copy)
1 -ec Freese & Nichols, Inc. Attn: B. Caleb Thornhill, P.E.
1 -ec JRJ Paving Attn: Mr. Marty Murphy
1 -ec The City of Coppell Attn: Mr. Larry Davis
Respectfully Submitted,
Alliance Geotechnical Group
r -
Robert P. Nance, Sr. Project Manager
Type 1
Type 2 Type 3 Type 4
Type 5 Type 6
Specification:
4,000 psi @ 28 days
Date Received:
07/07/2010
Slump: 2.5 Inches
Transported By: Southern Star
Curing Method:
Standard
Air Content: 2.8%
Source /Sampled At: Truck / Center
Time Sampled:
1:30 pm
Plant: #111
Temp.: Ambient:
92 °F Mix: 94 °F
Mix Code: 9363
Truck/Ticket No: 6235 / 1685133
Quantity Represented: 5 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -ec copy)
1 -ec Freese & Nichols, Inc. Attn: B. Caleb Thornhill, P.E.
1 -ec JRJ Paving Attn: Mr. Marty Murphy
1 -ec The City of Coppell Attn: Mr. Larry Davis
Respectfully Submitted,
Alliance Geotechnical Group
r -
Robert P. Nance, Sr. Project Manager
RuUAncE
G cEorEcnrocAL
Cffi UP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID:
1770 File No: C10 -0631
Date Sampled: 07/07/2010
Report Date: 07/14/2010
Sampled By: Jon Schuler
Project:
Bethel Road Paving & Utility Improvements
By Order Of: Larry Davis
Location:
Bridge Piers
Order Number: Vendor #9176
Contractor:
JRJ Paving
Client:
The City of Coppell
REPORT:
Soils Attachment
LAB NO: 87260 -1
Test Method: See Below
TEST RESULTS Report No: 87260 -1
Page 1 of 1
Remarks: See attached report.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -ec copy)
1 -ec Freese & Nichols, Inc. Attn: B. Caleb Thornhill, P.E.
1 -ec JRJ Paving Attn: Mr. Marty Murphy
1 -ec The City of Coppell Attn: Mr. Larry Davis
Respectfully Submitted,
Alliance Geotechnical Group
Y 4 . 9--
Robert P. Nance, Sr. Project Manager
MOISTURE DENSITY RELATIONSHIP REPORT
123 ! i . i • 1
I
1
i 1 I
118 I I I i
■
I
113 I , I , � I i
-- —
T
C i e
_
108 •
i 1'!
j ri.—:
I , ... Sp.G. _
_
i I _ 2.65
103
1
i
- -- - - - ■
6.5 9.0 11.5 14.0 16.5 19.0 21.5
Water content,
i
Test specification: ASTM D 698 -00 Procedure A Standard
i
Elev/ Classification Nat. % > % <
Sp.G. LL PI
Depth USCS AASHTO Moist. No,4 No.200
30 15
TEST RESULTS MATERIAL DESCRIPTION
Maximum dry density = 114.9 pcf ORANGE1SH YELLOW & LIGIIT BROWN
CLAYEY SAND
Optimum moisture = 13.3 %
Project No. C10 -0631 Client: The City of Coppell Remarks:
Project: Bethel Road II C10 -0631 - 87809 •' >
AGG 4/
• Location: STOCKPILE (SAMPLED 07-14-2010) -
MOISTURE DENSITY RELATIONSHIP REPORT
ALLIANCE GEOTECHNICAL GROUP Figure 8052
R�UAncE
G GI'IfCRL
GRC?UP EOTECH
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID:
1299 File No: C10 -0631
Date Sampled: 07/07/2010
Report Date: 07/14/2010
Sampled By: Jon Schuler
Project:
Bethel Road Paving & Utility Improvements
By Order Of: Larry Davis
Location:
Order Number: Vendor #9176
Contractor:
JRJ Paving
Client:
The City of Coppell
REPORT:
Cylinder Pick -Up
LAB NO: 87260 -2
TEST RESULTS Report No: 87260 -2
Page 1 of 1
Remarks: On this date a representative of AGG reported to the project site to pick -up cylinders.
Charge: JRJ Paving Attn: Mr. Marty Murphy
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -ec copy)
1 -ec Freese & Nichols, Inc. Attn: B. Caleb Thornhill, P.E.
1 -ec JRJ Paving Attn: Mr. Marty Murphy
1 -ec The City of Coppell Attn: Mr. Larry Davis
Respectfully Submitted,
Alliance Geotechnical Group
Robert P. Nance, Sr. Project Manager