Loading...
PA0101-LR010510CONCRETE COMPRESSIVE STRENGTH TEST ~.,~,.~,,..onr~--~. E~il NEEPJ N(], L~...'. 8901 Carpenter Frwy., Suite #100 Report Number: 94011093.0010 Dallas, Texas 75247 Service Date: April 30, 2001 (214) 63O-lOlO Client: City of Coppell - Parks & Recreation Report Date: May 10, 2001 Attn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 10:00am Technician: Jessie Tipton Batch Time: 9:15am Plant: 41 Weather Conditions: Partly cloudy, light wind Supplier: TXI Accumulative Yards: 80 Truck No: 110 Ticket No: 2876396 Placement Method: Direct discharge Mix I.D. No.: 8272 Sample Locations: See placement location Placement Location: East wall of main parking & approximately 100' of east drive area Sample location: 25' S of N curbline, 40' W of E curbline Field Test Data Test Result Specification Test Method Slump, inches: 4.75 5.0 Max ASTM C-143 Air Content, %: 5.2 N/A ASTM C-172 Concrete Temperature,o F: 78 ASTM C-39 Ambient Temperature, 0 F: 68 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 1 1 6.00 05/07/2001 7 90,030 3,180 1 2 6.00 05/07/2001 7 81,730 2,890 Average 3,040 1 3 05/28/2001 28 1 4 05/28/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4 c. .... .;..~..,.,...~. CONCRETE COMPRESSIVE STRENGTH TEST '~-~}INEER.II~]. I~. 8901 Carpenter Frwy., Suite #100 Report Number: 94011093.0010 Dallas, Texas 75247 Service Date: April 30, 2001 (214) 63o-101o Client: City of Coppell - Parks & Recreation Report Date: May 10, 2001 Attn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Sample Information Specified Strength: 3000 psi ~; 28 Days Sample Time: 11:30am Technician: Jessie Tipton Batch Time: 10:56am Plant: 41 Weather Conditions: Partly cloudy, light wind Supplier: TXI Accumulative Yards: 170 Truck No: 483 Ticket No: 2876629 Placement Method: Direct discharge Mix I.D. No.: 8272 Sample Locations: See placement location Placement Location: See page 1 Sample location: 30' N of S curbline, 40' W of E curbline Field Test Data Test Result Specification Test Method Slump, inches: 5.00 5.0 Max ASTM C-143 Air Content, %: 4.8 N/A ASTM C-172 Concrete Temperature,O F: 79 ASTM C-39 Ambient Temperature, 0 F: 74 Plastic Unit Weight, pcf: Laboratorv Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 2 1 6.00 05/07/2001 7 92,760 3,280 2 2 6.00 05/07/2001 7 94,420 3,340 Average 3,310 2 3 05/28/2001 28 2 4 05/28/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4 ~, .L,;-~.o.~,.-,,.,~ CONCRETE COMPRESSIVE STRENGTH TEST ~o,~...,o,,o~r..--~. I~N(;I.~ -EF_PJ ~;. ~.~. 8901 Carpenter Fray., Suite #100 Report Number: 94011093.0010 Dallas, Texas 75247 Service Date: April 30, 2001 (214) 63O-lOlO Client: City of Coppell - Parks & Recreation Report Date: May 10, 2001 Attn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 2:30pm Technician: Jessie Tipton Batch Time: 1:45pm Plant: 41 Weather Conditions: Partly cloudy, warm Supplier: TXI Accumulative Yards: 280 Truck No: 280 Ticket No: 2877071 Placement Method: Direct discharge Mix I.D. No.: 8272 Sample Locations: See placement location Placement Location: See page 1 Sample location: 15' W of E curbline,80' S of N curbline Field Test Data Test Result Specification Test Method Slump, inches: 5.00 5.0 Max ASTM C-143 Air Content, %: 5.1 N/A ASTM C-172 Concrete Temperature, o F: 86 ASTM C-39 Ambient Temperature, o F: 80 Plastic Unit Weight, pcf: Laboratorv Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load SSt~ No. ID (inches) Tested (days) (lbs) 3 1 6.00 05/07/2001 7 85,890 3 2 6.00 05/07/2001 7 90,750 Average 3,130 3 3 05/28/2001 28 3 4 05/28/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicabie ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 ~" "-"-~ ........ CONCRETE COMPRESSIVE STRENGTH TEST [~q(H NEARING, 8901 Carpenter Frwy., Suite #100 Report Number: 94011093.0010 Dallas, Texas 75247 Service Date: April 30, 2001 (214) 63O-lOlO Client: City of Coppell - Parks & Recreation Report Date: May 10, 2001 Attn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 5:00pm Technician: Jessie Tipton ~3atch Time: 4:15pm Plant: 41 Weather Conditions: Light wind, warm Supplier: TXI l-ruck No: 110 Ticket No: 2877082 Placement Method: Mix I.D. No.: 8272 Sample Locations: See placement location Placement Location: See page 1 Sample location: 20' E of E curb, on E drive area Field Test Data Test Result Specification Test Method Slump, inches: 4.50 5.0 Max ASTM C-143 Air Content, %: 4.9 N/A ASTM C-172 Concrete Temperature,O F: 89 ASTM C-39 Ambient Temperature, o F: 83 Plastic Unit Weight, pcf: Laboratorv Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 4 1 6.00 05/07/2001 7 79,540 2,810 4 2 6.00 05/07/2001 7 85,660 3,030 Average 2,920 4 3 05/28/2001 28 4 4 05/28/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jessie Tipton //--, .~ / ~..,. Report Distribution: ~ Inc. (1) City of Coppell - Parks & Recreation (1) TLR Construction Reviewed by: (1) City of Coppell - Constr. Insp. Eric J. Cleveland. P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materia',s. Page 4 of 4 : ........ -"-~-"-' ....