Tennis Ctr Exp-LR100722Professional Service Industries, Inc.
4087 Shilling Way
Dallas, TX 75237
Texas Firm Registration No. F-03307
Phone: (214) 330-9211
Fax: (214) 333-2853
Report No: PTR:0341284-2-S2
Proctor Test Report
Issue No: 1
Client:CC:
SCHMOLDT CONSTRUCTIONCARY SCHMOLDT
These test results apply only to the specific locations and materials noted
and may not represent any other locations or elevations. This report may
5797 CR 126, SUITE ACHRIS HOUSE
not be reproduced, except in full, without written permission by
CELINA, 75009GEORGE MARSHAL
Professional Service Industries, Inc.
HILLARY WHITE
JOHN ELIAS
Project:
COPPELL TENNIS CENTERJOHN FIELDER
COPPELL, TX
LARRY DAVIS
Approved Signatory: Ronald Yeoman (Project Manager)
Date of Issue:7/28/2010
Sample Details
Sample ID:Date Sampled:
0341284-2-S27/21/2010
Sampling Method:
Stockpile/Trans - ASTM D 75 - 5.3.3
Source:Material:
Onsite MaterialDark Brown and Tan Clay
Specification:
95
Location:
North Half of Tennis Court Area, Elev: SG
Tested By:Date Tested:
Ronald Yeoman7/22/2010
Dry Density - Moisture Content RelationshipTest Results
ASTM D 698 - 07
Maximum Dry Density (lbf/ft³):89.7
Optimum Moisture Content (%):26.4
Method:A
Preparation Method:Moist
Apparent SG (Fines):2.65
Retained Sieve No 4 (4.75mm) (%):0
Comments
Page 1 of 1
Form No: 110031.V1.00, Report No: PTR:0341284-2-S2(c) 2000-2009 QESTLab by SpectraQEST.com