Loading...
ST0301A-LR100803 (2)R�UAncE G GEOTECHI'IfCRL GRC?UP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C10 -0631 Date Sampled: 07/28/2010 Report Date: 08/03/2010 Sampled By: Robert Nance Project: Bethel Road Paving & Utility Improvements By Order Of: Larry Davis Location: Bridge Bent #2 Order Number: Vendor #9176 Contractor: JRJ Paving Client: The City of Coppell REPORT: Reinforcing Steel Inspection LAB NO: 88532 TEST RESULTS Report No: 88532 Page 1 of 1 We visually inspected the reinforcing steel at Bridge Bent #2. Our inspection included verifying the proper size of the reinforcing steel including diameter, length, bends and anchorage, and the grade and the location of the bars including spacing and cover. We also verified proper splicing, checked stability of tying, and checked the reinforcing steel for excessive rust deposits. On the basis of our visual inspection, the reinforcing steel placement meets the requirements of the project plans and specifications. • Size: 4 - #11's top and bottom with #5 stirrups • Cover: 3" • Splice Length: bars were continuous • Cleanliness: Clean • Properly Tied: Yes • Cleanliness of Form Work: Clean • Proper Support: Yes Remarks: Plan Sheet ST -8 Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E. Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. (1 -ec copy) 1 -ec Freese & Nichols, Inc. Attn: B. Caleb Thornhill, P.E. 1 -ec JRJ Paving Attn: Mr. Marty Murphy 1 -ec The City of Coppell Attn: Mr. Larry Davis Respectfully Submitted, Alliance Geotechnical Group Robert P. Nance, Sr. Project Manager R�UAncE G GEOTECHI'IfCRL GRC?UP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C10 -0631 Date Sampled: 07/29/2010 Report Date: 08/03/2010 Sampled By: Robert Nance Project: Bethel Road Paving & Utility Improvements By Order Of: Larry Davis Location: Bridge Abutment #1 Order Number: Vendor #9176 Contractor: JRJ Paving Client: The City of Coppell REPORT: Reinforcing Steel Inspection LAB NO: 88459 TEST RESULTS Report No: 88459 Page 1 of 1 We visually inspected the reinforcing steel at the Bridge Abutment #1. Our inspection included verifying the proper size of the reinforcing steel including diameter, length, bends and anchorage, and the grade and the location of the bars including spacing and cover. We also verified proper splicing, checked stability of tying, and checked the reinforcing steel for excessive rust deposits. On the basis of our visual inspection, the reinforcing steel placement meets the requirements of the project plans and specifications. • Size: 6 - #11's • Cover: 2" • Splice Length: NA • Cleanliness: Clean • Properly Tied: Yes • Cleanliness of Form Work: Clean • Proper Support: Yes Remarks: Plan Sheet ST3 Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E. Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. (1 -ec copy) 1 -ec Freese & Nichols, Inc. Attn: B. Caleb Thornhill, P.E. 1 -ec JRJ Paving Attn: Mr. Marty Murphy 1 -ec The City of Coppell Attn: Mr. Larry Davis Respectfully Submitted, Alliance Geotechnical Group Robert P. Nance, Sr. Project Manager