ST8505-CS 870716HAYNES, HE~LLON ~, ASSOCIATES,
Testing. Inspeot~on ~, IVlater~als Engineers
7800 Brookhollow I~oad · P 0 Box ~5~81
[Dallas. Texas 75235 · (214) 631-4372
REPORT NO 1
JOB NO. 1 5 1 9 0
DATE 7/16/87
Ed Bell Construction Co.
PROJECT Belt Line Rd. TESTEDFOR P. O. Box 20871
E. B. Job No. 780 Dallas, Texas 75220
Attn: Mr. Melvin Ford
CONCRETE COMPRESSION TEST REPORT
I6 x 12 INCH) NOMINAL CYLINDER SIZE AREA-28.26 SO IN
COMPRESSIVE STRENGTH TEST RESULTS
CYLINDER NO, BL70801 BT.70802
AGE -DAYS 7 7
FIELD CURE-DAYS -- --
STANDARD CURE-DAYS 7 7
UNIT LOAD 126,000 118,000
PSI 4460 4170
DATE MOLDED 7/8/87 7/8/87
DATE RECEIVED -- --
DATE TESTED 7/15/87 7/15/87
SPECIFICATIONS:
AGE-DAYS 28 28
STRENGT,-~-.S, 3000 3000
LOCATIONS OF POURS REMARKS Unit Wt. = 149.7 p.c.f.
Our Laboratory Yield = 26.99 cu. ft.
CYLINDERS MOLDED 8Y HAYNES. HOLLON ~ ] CYLINDERS MOLDED BY ARCHITECT'S OR :
& ASSOCIATES, INC. REPRESENTATIVE L__~ CONTRACTOR'S REPRESENTATIVE i
CYLINDER NO, BL7080 1 -02
MIX DESIGN NO 3
SLUMP IN 1 3/4
AIR CONTENT % 3.8
AIR TEMP. "F 7 4
CONCRETE TEMP ° F 72
FIELD DATA SUBMITTED BY
MIX DATA SUBMITTED BY' L. Johnson
CYLINDERS PICKED UP BY HAYNES,
HOLLON & ASSOCIATES, INC. REP
I CYLINDERS DELIVERED TO HAYNES,
· j HOLLON & ASSOCIATES. INC.
DISTRIBUTION City of Coppell
OO4
FIELD DATA
CONCRETE BATCH PLANT
DELIVERY TICKET NO
MIX PROPORTIONS (SSD)
CEMENT {TYPE)
FINE AGGREGATE
COARSE AGGREGATE
WATER ( 2 7 · 6
gallons)
470
1270
2070
230
ADMIXTURES Daravair - M 2.25 fi. oz
Daratered - 17 14 fl. oz.
~ ~ COMPRESSIVE STRENGTH RESULTECOMPLY
L×J
WITH APPLICABLE SPECIFICATIONS
~---i COMPRESSIVE. STRENGTH RESULTS DO NOT
~___j COMPLY WITH APPLICABLE SPECIFICATIONS
RESPECTFULLY SUBMITTED.
HAYNES. HC3LLON & ASSOC:31ATES, !r~ORPORATEO
Testing, Inspeotion ~, Materials Engineers
7800 Brookhollo~, Road · P 0 ~ox ~5481
Dallas, Texas 75235 . (214) 631-4372
REPORT NO. 2
JOB NO. 15190
DATE 7/16/87
Ed Bell Construction Co.
PROJECT~ Belt Line Rd. TESTEDFOR P. O. BOX 20871
E.B. Job NO. 780 Dallas, Texas 75220
Attn: Mr. Melvin Ford
CONCRETE COMPRESSION TEST REPORT
lEx 12 INCH) NOMINAL CYLINDER SIZE AREA-28.26SO. IN
COMPRESSIVE STRENGTH TEST RESULTS
CYLINDER NO. BL70801 BL70802
AGE -DAYS 7 7
FIELD CURE-DAYS -- --
STANDARD CURE-DAYS 7 7
UNIT LOAD 137,000 132,500
PSI 4840 4690
DATE MOLDED 7/8/87 7/8/87
DATE RECEIVED -- --
DATE TESTED 7/15/87 7/15/87
SPECIFICATIONS:
AC, E--DAYS 28 28
3000 3000
STRENGTH-PSI
LOCATIONS OF POURS REMARKS
Unit Wt. = 148.3 p.c.f.
Our Laboratory Yield = 27.13 cu. ft.
- CYLINDERS MOLDED BY HAYNES. ROLLON ~ ~ CYLINDERS MOLDED BY ARCHITECT'S OR
& ASSOCIATES, INC REPRESENTATIVE [ i CONTRACTOR'S REPRESENTATIVE
FIELD DATA
CYLINDER NO. BLT 0801 - 02 CONCRETE BATCH PLANT
MIX DESIGN NO 4 DELIVERY TICKET NO
SLUMP IN 4 MIX PROPORTIONS {SSD):
AIR CONTENT % 3 . 9 CEMENT (TYPE) 564
AIR TEMP. 'F 74 FINE AGGREGATE 1 140
CONCRETE TEMP °F 75 COARSE AGGREGATE 2070
FIELD DATA SUBMITTED BY WATER ( 30.0 gallons ) 250
MIX DATA SUBMITTED BY: L. Johnson ADMIXTURES Daravair - M 2.75 fl.oz.
Daratard - 17 17 fl.oz.
CYLINDERS PICKED UP BY HAYNES.
HOLLON & ASSOCIATES, INC. REP
?-' ~ CYLINDERS DELIVERED TO HAYNES,
~ HOLLON & ASSOCIATES, INC
DISTRIBUTION
City of Coppell
~ OOa
~Xi COMPRESSIVE STRENGTH RESULTS COMPLY
WITH APPLICABLE SPECIFICATIONS
~-'~ COMPRESSIVE STRENGTH RESULTS DO NOT
] _ j COMPLY WITH APPLICABLE SPECIFICATIONS
RESPECTFULLY SUBMITTED,