Loading...
WA9903-CS000505 (2)SHIMEK, JACOBS & FINKI.EA, L.L.P. CONSULTING ENGINEERS 8333 Douglas Avenue, #820 Dallas, Texas 75225-5816 Fax (214) 361-0204 Phone (214) 361-7900 RONALD V. CONV~/AY, P.E. JOHN W. BIRKHOFF, P.E. JOE R. CARTER, P.E. GARY C. HENDRICKS, P.E. PAUL A. CARLINE, P.E. MATT HICKEY, P.E. ROSS L. JACOBS, P.E. I. C. FINKLEA, P.E. JOHN R. BAUMGARTNER, P.E. · i ~ May 5, 2000 Transmitted via Facs Architectural Utilities, Inc., dba AUI General Contractors 300 W. Ramsey Fort Worth, Texas 76110 Re: City of Coppell Addition of Pump Number 4 Gentlemen: After observing the physical condition of the 600 horsepower General Electric motor at the job site for the Addition of Pump Number 4 at the Village Parkway Pump Station, the City of Coppell has some doubts that the motor is in fact new. On behalf of the City we are requesting verification that the motor provided is new and not re-built or reconditioned. Using serial numbers on the motor housing, please have the motor manufacturer provide verification of the date of manufacture, customer name, shipping date and delivery location. In addition, we request a representative of the motor manufacturer meet with us at the job site to verify the data and operating condition of the motor. Any other data you, the pump supplier or the motor manufacturer can supply to verify the status of the motor would be helpful. In the meantime, it is advisable not to connect the motor to the pump nor otherwise start the motor until the motor is verified as new. Please coordinate and provide this information at your earliest convenience and notify us of the date for the meeting with the manufacturer' s representative. If you have any questions or need additional direction, please do not hesitate to contact this office. P.E. cc: Mr. Kenneth M. Griffin, P.E Mr/Glenn D. Hollowell, P.E t,~r. Larry Davis j:\clerical\coppell\1999-153\letwrs\cons6kXmotor condition.doe '! I l' DEC 83 1999 18:47 FR G.~UPPLY 972 388 ?036 TO 9"~3332785 P.81/05 > q To ~A~I L F co~.p~. ~/~ ~T~ Control Systems Customer Service Dept Fort Wayne, IN 46802 (219) 439-2000 Customer: Customer Requested DataPack Genented by EDDS/CustomerLink Customer Order ....................: NONE Customer Part .......................:None GEICS Reqn / Item ...............: None GEICS Job Number ..............:NONE MODEl. NUMRF. R ...............: 5KSS13AN3661VI Outline Drawing ....................: 50DP4109G004AG Connection Diagram .............: GEM2034E-FIG7 Desi!~n Code: ..........................: 50DS3544CW Type ........................................: KS Frame ......................................: 5013S Phases .....................................: 3 Poles ........................................: 6 Horsepower .............................600 RPM .........................................1190 Voltage ....................................: 4160 Hertz ........................................60 Amps - FL ...............................80.5 Service Factor .........................1.15 I~.STIM~,T~.Y} WY.I~HT ....... : 5180 Lbs (2349.65Kg) Time Rating ............................: CONT Enclosure ................................: WPI Encl Construction ..................: OPEN Ambient ..................................: 40 Insulation Class ......................: F NEMA Design ........................: - Nominal Efficiency ................: 95.8 Guaranteed Effideney ...........: 95.4 KVA Code ..............................: G Max KVAR. ............................: 212.3 Power Factor ................' ..........: 80,5 Bearing - DE ...........................: 6320ZC3 Bearing - ODE ........................: 6320ZC3 Enclosure is Weather Protected One OPEN Addi~on~iMn~r Data: GREASE RYKON PREM #2 HTR LDS H ll5V 350W 6P-FORM COIL-WPI FEAT-115V HTR LDS & 100 0HMWDG RTD LDS TO ACESS BOX *******SPIDER ARM SET******************* C!:!N~CrInN TX T3 ~ T2 V0L'k'~ LL L~ L3 |& 5INC~E rl T2 T3 PaEe I FIG. 1 HEATER CONN. · · · VOLTAGE ONLY II ! I ,, I f