Loading...
WA9903-CS000505' SHIMEK, JACOBS & FINKI.EA, L.L.P. CONSULTING ENGINEERS 8333 Douglas Avenue, #820 Dallas, Texas 75225-5816 Fax (214) 361-0204 Phone (214) 361-7900 RONALD V. CONWAY, P.E. JOHN W. BIRKHOFF, P.E. JOE R. CARTER, P.E. GARY C. HENDRICKS, P.E. PAUL A. CARLINE, P.E. MATT HICKEY, P.E. ROSS L. JACOBS, P.E. I. C. FINKLEA, P.E. JOHN R. BAUMGARTNER, P.E. May 5, 2000 Transmitted via Facsimile Architectur tilities, Inc., dba AUI General Contractors 300 W. msey Re: City of Coppell Addition of Pump Number 4 Gentlemen: After observing the physical condition of the 600 horsepower General Electric motor at the job site for the Addition of Pump Number 4 at the Village Parkway Pump Station, the City of Coppell has some doubts that the motor is in fact new. On behalf of the City we are requesting verification that the motor provided is new and not re-built or reconditioned. Using serial numbers on the motor housing, please have the motor manufacturer provide verification of the date of manufacture, customer name, shipping date and delivery location. In addition, we request a representative of the motor manufacturer meet with us at the job site to verify the data and operating condition of the motor. Any other data you, the pump supplier or the motor manufacturer can supply to verify the status of the motor would be helpful. In the meantime, it is advisable not to connect the motor to the pump nor otherwise start the motor until the motor is verified as new. Please coordinate and provide this information at your earliest convenience and notify us of the date for the meeting with the manufacmrer's representative. If you have any questions or need additional direction, please do not hesitate to contact this office. co: c~r.r. Kenneth M. Griffin, P.E Mr. Glenn D. Hollowell, P.E Mr. Larry Davis .Since ly;ur/ , ~Lks, I;.E. j:\clerical\coppell\ 1999-153\leUers\constLk~notor condition. doe ! ! 10:4~ FR G..~SUPPLY 9?2 389 ~036 TO '~43332~85 P.01/05 GE Industrial Control Systems Customer Service Dept Fort Wayne, IN 46802 (219) 439-2000 Customer: Customer Requested DataPaCk Genented by EDDS/CustomerLink Customer Order .................... :NONE Customer Part ....................... :None GEICS Reqn/Item ............... :None GEICS Job Number .............. : NONE MODJF. t. NUMa~R ............... : 5KSS13AN366M Outline Drawing .................... : 50DP4 109G004AG Connection Diagram ............. : GEM2034E-FIG7 Design Code ~ ...........................50DS3544CW Type .........................................KS Frame .......................................5013S Phases ......................................3 Poles .........................................6 Horsepower .............................600 RPM .........................................1190 Voltage .....................................4160 Hertz ........................................60 Amps - FL ...............................80.5 Service Factor .........................1.15 ESTIM~kTRD W'F, IC, HT ....... : 51110 Lbs (2349.65Kg) Time Rating .............................CONT Enclosure .................................WPI Encl Construction ................... OPEN Ambient ....... : ...........................40 Insulation Class ......................: F NEMA Design ......................... - NOminal Efficiency ................. 95.8 Guaranteed Efficiency ........... : 95.4 KVA Code ..............................: G Max KVAIL ............................: 2 123 Power Factor ..........................: 80.5 Bearing- DE ...........................: 6320ZC3 Bearing- ODE ........................ : 6320ZC3 Enclosure is Weather Protected One OPEN AddMonalMn~r Dam: GREASE RYKON PREM #2 HTR LDS H l15V 350W 6P-FORMCOIL-WPI FEAT-115V HTR LDS& 100 OHM WDG RTD LDS TO ACESS BOX *******SPIDER ARM SHAFT******************* ISIN~E VOLTAGE I )CTII3N a T1 T3/~.1.2 VOLT~ LL L.~ L,3 I a SINGLE TI T~ T3 Paue 1 FIG. 1 HEATER CONN. ---! ) · CONTROL VOLTAGE ONLY