Tennis Ctr Exp-LR101007Professional Service Industries, Inc.
4087 Shilling Way
Dallas, TX 75237
Texas Firm Registration No. F-03307
Phone: (214) 330-9211
Fax: (214) 333-2853
Report No: CON:0341284-24-C1
Concrete Test Report
Issue No: 1
Client:CC:
SCHMOLDT CONSTRUCTIONCARY SCHMOLDT
These test results apply only to the specific locations and materials noted
and may not represent any other locations or elevations. This report may
5797 CR 126, SUITE ACHRIS HOUSE
not be reproduced, except in full, without written permission by
CELINA, 75009GEORGE MARSHAL
Professional Service Industries, Inc.
HILLARY WHITE
JOHN ELIAS
Project:
COPPELL TENNIS CENTERJOHN FIELDER
COPPELL, TX
LARRY DAVIS
Approved Signatory: Ronald Yeoman (Project Manager)
LEE STONE
Date of Issue:10/7/2010
Mix Data
Supplier
Lattimore Materials
Mix Identification
5077
Specified Design Strength (psi)
3000at age28days
Details of Sample
Date SampledDate ReceivedMeasuredSpecified
9/29/2010
Slump (in)
4.25
General LocationBldg. Slab AdditionSlump w/ plasticizer (in)
N/A
5'S/5'E of the NW Corner of Bldg. Slab
Sample LocationAir Temp (°F)
62
Curing MethodConcrete Temp (°F)
78
ASTM C 1064
Field Sample NoField Cure Temp (°F)HighAir Content (%)
4.60
ASTM C 231
LowUnit Weight (pcf)
ASTM C 138
ContractorBatch Size (yd³)
10
Truck No.Ticket No.Water Added (gal)Before
70586378070
Sampled ByAfter
Kevin Graham
Submitted ByTime Batched05:54
Kevin Graham
WeatherTime Sampled06:35
Mild and Clear
Est. Wind (mph)Yd³ Placed10.0Time Placed06:45
Est. Rh (%)Time In Truck (mins)51
Compressive Strength of Concrete CylindersASTM C 39
Specimen IDDate TestedAgeDimensions (in)Area (in²)Type ofUltimateType ofCompressiveRequired
(days)CapLoad (lbf)FractureStrength (psi)Strength (psi)
DiameterHeight
0341284-24-C1\110/06/1075.9712.0027.99U11339024050
0341284-24-C1\210/06/1075.9712.0027.99U11894034250
0341284-24-C1\310/27/1028U3000
0341284-24-C1\410/27/1028U3000
NotesRemarks
1.Sampling to ASTM C 172FailureMode: 2 = C39: Vert crack/ cone opposite end; C1314: Cone & Shear, 3 = C39: Vert
2.Specimen(s) Prepared to ASTM C 31cracking/no cones; C1314: Cone & Split
3.Capping B=Bonded ASTM C 617, U=Unbonded ASTM C 1231, C = Combined
Form No: 18970.V1.00, Report No: CON:0341284-24-C1(c) 2000-2009 QESTLab by SpectraQEST.com Page 1 of 1