Loading...
Tennis Ctr Exp-LR101027 (2)Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No:RSI:0341284-32/1 Reinforcing Steel Inspection Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A  reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX Date of Issue: 10/27/2010 Date: Technician: 10/20/2010 Quwan Shields Location Footing Slab-on-grade Elevated slab Piers Columns Beam Pilaster Wall Panel Foundation Wall Other Post Tension Tendons Building/Unit No. Tennis Courts 9 & 10 Elevation: Specific Location (grid lines): Plans Used: Contract Drawings Approved Shop Drawings Current Date and Revision/Submittal No. on Drawings: March 2010 Drawing (page) and Detail Nos.: S-1, S-3, Details # 1, 2, 3, & 5 Item Yes No N/A Item Yes No N/A Size & number of bars as specified Bars properly tied and positioned Lap lengths as specified Spacing of bars as specified Bars clean (no foreign matter) Dowels in place and tied Clearance around rebar as specified Epoxy coating specified Rebar epoxy coated Non-Conformance Items Description Who Notified How / Date Corrected Remarks: All P/T tendons installed in tennis courts 9 & 10 were all accounted for with chairs underneath. Page 1 of 1  Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No:RSI:0341284-26/1 Reinforcing Steel Inspection Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A  reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX Date of Issue: 10/27/2010 Date: Technician: 10/7/2010 Ronald Yeoman Location Footing Slab-on-grade Elevated slab Piers Columns Beam Pilaster Wall Panel Foundation Wall Other Building/Unit No. Courts # 11 & 12 Elevation: N/A Specific Location (grid lines): Entire Tennis Court Slabs Plans Used: Contract Drawings Approved Shop Drawings Current Date and Revision/Submittal No. on Drawings: 3/22/2010/45193 Drawing (page) and Detail Nos.: S-2, S-3, S-4 Item Yes No N/A Item Yes No N/A Size & number of bars as specified Bars properly tied and positioned Lap lengths as specified Spacing of bars as specified Bars clean (no foreign matter) Dowels in place and tied Clearance around rebar as specified Epoxy coating specified Rebar epoxy coated Non-Conformance Items Description Who Notified How / Date Corrected Cables will be chained in the morning before the PT cables were not chained per plans & Chris w/Schmoldt placement of concrete and it will be verified by a PSI specifications field technician. Proper clearance between leave outs and post Cables and leave outs were adjusted and fixed per tention cables was not met. plan and specifications while technician was on site. Remarks: Page 1 of 1  Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: PST:0341284-31/1 Post Tension Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE,  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX LOUIE LAUCK, Date of Issue: 10/27/2010 Date: Technician: 10/19/2010 Ronald Yeoman Location: Floor: Tennis Courts 11 & 12 S0G Pour: Serial No. of Gauge: Serial No. of Ram: #1 313993 022101 Strand Heat No: Strand MFG.: N/A N/A Contractor: Schmoldt Approved Drawings : S-1, Dated: 3/22/2010 (Strand Placement Shop Drawings) Stressed By: Verified By: Ronald Yeoman TENDON GAUGE PRESSURE CALC MEASURED ELONGATION % NO. ELONG JACKING LIFT OFF END 1 END 2 TOTAL 1/S-45 3.500 3.380 3.380 -3.4 2/S-52 4.000 4.000 4.000 0 3/S-59 4.250 4.000 4.000 -5.9 4/S-129 10.380 10.000 10.000 .3-7 5/S-129 10.380 10.000 10.000 -3.7 6/S-129 10.380 10.140 10.250 -1.3 7/S-129 10.380 9.880 9.880 -4.8 8/S-129 10.380 9.880 9.880 -4.8 9/S-129 10.380 10.000 10.000 -3.7 10/S-129 10.380 10.500 10.500 1.2 11/S-129 10.380 10.000 10.000 -3.7 12/S-129 10.380 10.250 10.250 -1.3 13/S-129 10.380 11.000 11.000 6.0 14/S-129 10.380 10.500 10.500 1.2 15/S-129 10.380 10.380 10.380 0 16/S-129 10.380 10.500 10.380 0 17//S-129 10.380 10.500 10.500 1.2 Review is only for conformance with design concept of this project and compliance with the intent of the contract documents. No exceptions observed by: Ronald Yeoman Make corrections observed by: Page 1 of 5  Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: PST:0341284-31/1 Post Tension Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE,  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX LOUIE LAUCK, Date of Issue: 10/27/2010 Date: Technician: 10/19/2010 Ronald Yeoman Location: Floor: Tennis Courts 11 & 12 S0G Pour: Serial No. of Gauge: Serial No. of Ram: #1 313993 022101 Strand Heat No: Strand MFG.: N/A N/A Contractor: Schmoldt Approved Drawings : S-1, Dated: 3/22/2010 (Strand Placement Shop Drawings) Stressed By: Verified By: Ronald Yeoman GAUGE PRESSURE MEASURED ELONGATION TENDON CALC % NO. ELONG JACKING LIFT OFF END 1 END 2 TOTAL 69/S-126 9.940 10.250 10.250 3.1 70/S-126 9.940 10.000 10.000 0.6 71/S-126 9.940 10.130 10.130 1.9 72/S-126 9.940 10.250 10.250 3.1 73/S-126 9.940 10.000 10.000 0.6 74/S-126 9.940 10.130 10.130 1.9 75/S-119 9.250 9.000 9.000 -2.7 76/S-112 8.750 8.500 8.500 -2.9 77/S-105 8.250 8.000 8.000 -3.0 Review is only for conformance with design concept of this project and compliance with the intent of the contract documents. No exceptions observed by: Ronald Yeoman Make corrections observed by: Page 2 of 5  Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: PST:0341284-31/1 Post Tension Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE,  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX LOUIE LAUCK, Date of Issue: 10/27/2010 Date: Technician: 10/19/2010 Ronald Yeoman Location: Floor: Tennis Courts 11 & 12 S0G Pour: Serial No. of Gauge: Serial No. of Ram: #1 313993 022101 Strand Heat No: Strand MFG.: N/A N/A Contractor: Schmoldt Approved Drawings : S-1, Dated: 3/22/2010 (Strand Placement Shop Drawings) Stressed By: Verified By: Ronald Yeoman GAUGE PRESSURE MEASURED ELONGATION TENDON CALC % NO. ELONG JACKING LIFT OFF END 1 END 2 TOTAL 35/S-45 3.500 3.500 3.500 0 36/S-45 3.500 3.250 3.250 -7.14 37/S-52 4.000 4.130 4.130 0 38/S-59 4.250 4.380 4.380 3.1 39/S-59 4.250 4.000 4.000 -5.9 40/S-52 4.000 3.880 3.880 -3.0 41/S-45 3.500 3.750 3.750 7.1 42/S-105 8.250 8.250 8.250 0 43/S-112 8.750 8.500 8.500 -2.9 44/S-119 9.250 9.000 9.000 -2.7 45/S-126 9.940 10.000 10.000 0.6 46/S-126 9.940 10.000 10.000 0.6 47/S-126 9.940 10.000 10.000 0.6 48/S-126 9.940 10.130 10.130 1.9 49/S-126 9.940 10.000 10.000 0.6 50/S-126 9.940 9.880 9.880 -0.6 51/S-126 9.940 9.880 9.880 -0.6 Review is only for conformance with design concept of this project and compliance with the intent of the contract documents. No exceptions observed by: Ronald Yeoman Make corrections observed by: Page 3 of 5  Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: PST:0341284-31/1 Post Tension Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE,  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX LOUIE LAUCK, Date of Issue: 10/27/2010 Date: Technician: 10/19/2010 Ronald Yeoman Location: Floor: Tennis Courts 11 & 12 S0G Pour: Serial No. of Gauge: Serial No. of Ram: #1 313993 022101 Strand Heat No: Strand MFG.: N/A N/A Contractor: Schmoldt Approved Drawings : S-1, Dated: 3/22/2010 (Strand Placement Shop Drawings) Stressed By: Verified By: Ronald Yeoman GAUGE PRESSURE MEASURED ELONGATION TENDON CALC % NO. ELONG JACKING LIFT OFF END 1 END 2 TOTAL 52/S-126 9.940 10.250 10.250 3.1 53/S-126 9.940 10.500 10.250 3.1 54/S-126 9.940 10.380 10.380 4.4 55/S-126 9.940 10.250 10.250 3.1 56/S-126 9.940 9.130 9.130 -1.3 57/S-119 9.250 9.130 9.130 -1.3 58/S-112 8.750 8.750 8.750 0 59/S-105 8.250 8.130 8.130 -1.5 60/S-105 8.250 8.131 8.130 -1.5 61/S-112 8.750 8.500 8.500 -2.9 62/S-119 9.250 9.250 9.250 0 63/S-126 9.940 10.000 10.000 0.6 64/S-126 9.940 10.000 10.000 0.6 65/S-126 9.940 10.130 10.130 1.9 66/S-126 9.940 10.130 10.130 1.9 67/S-126 9.940 10.130 10.130 1.9 68/S-126 9.940 10.130 10.130 1.9 Review is only for conformance with design concept of this project and compliance with the intent of the contract documents. No exceptions observed by: Ronald Yeoman Make corrections observed by: Page 4 of 5  Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: PST:0341284-31/1 Post Tension Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE,  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX LOUIE LAUCK, Date of Issue: 10/27/2010 Date: Technician: 10/19/2010 Ronald Yeoman Location: Floor: Tennis Courts 11 & 12 S0G Pour: Serial No. of Gauge: Serial No. of Ram: #1 313993 022101 Strand Heat No: Strand MFG.: N/A N/A Contractor: Schmoldt Approved Drawings : S-1, Dated: 3/22/2010 (Strand Placement Shop Drawings) Stressed By: Verified By: Ronald Yeoman GAUGE PRESSURE MEASURED ELONGATION TENDON CALC % NO. ELONG JACKING LIFT OFF END 1 END 2 TOTAL 18/S-129 10.380 10.500 10.500 1.2 19/S-129 10.380 10.500 10.500 1.2 20/S-129 10.380 10.500 10.500 1.2 21/S-129 10.380 10.500 10.500 1.2 22/S-129 10.380 10.500 10.500 1.2 23/S-129 10.380 10.500 10.500 1.2 24/S-129 10.380 10.500 10.500 1.2 25/S-129 10.380 10.500 10.500 1.2 26/S-129 10.380 10.130 10.130 -2.4 27/S-129 10.380 10.130 10.130 -2.4 28/S-129 10.380 10.250 10.250 -1.3 29/S-129 10.380 10.250 10.250 -1.3 30/S-129 10.380 10.500 10.500 1.2 31/S-129 10.380 10.250 10.250 -1.3 32/S-129 10.380 10.250 10.250 -1.3 33/S-59 4.250 4.130 4.130 -2.8 34/S-52 4.000 4.000 4.000 0 Review is only for conformance with design concept of this project and compliance with the intent of the contract documents. No exceptions observed by: Ronald Yeoman Make corrections observed by: Note: Remarks: Page 5 of 5