Loading...
Tennis Ctr Exp-LR101029Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: PST:0341284-35/1 Post Tension Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE,  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX LOUIE LAUCK, Date of Issue: 11/1/2010 Date: Technician: 10/29/2010 Ronnie Yeoman Location: Floor: Tennis Courts #9 and #10 SOG Pour: Serial No. of Gauge: Serial No. of Ram: #1 313993 022101 Strand Heat No: Strand MFG.: N/A N/A Contractor: Schmoldt Construction Approved Drawings : S-1, 3/22/2010 (Strand Placement Shop Drawings) Stressed By: Verified By: American Tennis Courts Ronnie Yeoman TENDON GAUGE PRESSURE CALC MEASURED ELONGATION % NO. ELONG JACKING LIFT OFF END 1 END 2 TOTAL 1/S-45 7300 0 3.500 3.380 3.380 0 2/S-52 7300 0 4.000 4.000 4.000 0 3/S-59 7300 0 4.500 4.250 4.250 -5.6 4/S-129 7300 0 10.380 10.000 10.000 -3.7 5/S-129 7300 0 10.380 10.000 10.000 -3.7 6/S-129 7300 0 10.380 10.250 10.250 -1.3 7/S-129 7300 0 10.380 10.000 10.000 -3.7 8/S-129 7300 0 10.380 10.130 10.130 -2.4 9/S-129 7300 0 10.380 10.130 10.130 -2.4 10/S-129 7300 0 10.380 10.130 10.130 -2.4 11/S-129 7300 0 10.380 10.000 10.000 -3.7 12/S-129 7300 0 10.380 9.750 9.750 -6.1 13/S-129 7300 0 10.380 10.000 10.000 -3.7 14/S-129 7300 0 10.380 10.000 10.000 -3.7 15/S-129 7300 0 10.380 10.130 10.130 -2.4 16/S-129 7300 0 10.380 10.130 10.130 -2.4 17/S-129 7300 0 10.380 10.000 10.000 -3.7 Review is only for conformance with design concept of this project and compliance with the intent of the contract documents. No exceptions observed by: Ronnie Yeoman Make corrections observed by: equivalent decimal fraction. Page 1 of 5  Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: PST:0341284-35/1 Post Tension Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE,  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX LOUIE LAUCK, Date of Issue: 11/1/2010 Date: Technician: 10/29/2010 Ronnie Yeoman Location: Floor: Tennis Courts #9 and #10 SOG Pour: Serial No. of Gauge: Serial No. of Ram: #1 313993 022101 Strand Heat No: Strand MFG.: N/A N/A Contractor: Schmoldt Construction Approved Drawings : S-1, 3/22/2010 (Strand Placement Shop Drawings) Stressed By: Verified By: American Tennis Courts Ronnie Yeoman TENDON GAUGE PRESSURE CALC MEASURED ELONGATION % NO. ELONG JACKING LIFT OFF END 1 END 2 TOTAL 18/S-129 7300 0 10.380 10.130 10.130 -2.4 19/S-129 7300 0 10.380 10.250 10.250 -1.3 20/S-129 7300 0 10.380 10.500 10.500 1.2 21/S129 7300 0 10.380 10.250 10.250 -1.3 22/S129 7300 0 10.380 10.130 10.130 -2.4 23/S129 7300 0 10.380 10.130 10.130 -2.4 24/S129 7300 0 10.380 10.000 10.000 -3.7 25/S129 7300 0 10.380 9.880 9.880 -4.8 26/S129 7300 0 10.380 10.000 10.000 -3.7 27/S129 7300 0 10.380 10.000 10.000 -3.7 28/S129 7300 0 10.380 10.000 10.000 -3.7 29/S129 7300 0 10.380 10.380 10.380 0 30/S129 7300 0 10.380 10.380 10.380 0 31/S129 7300 0 10.380 10.130 10.130 -2.4 32/S129 7300 0 10.380 10.000 10.000 -3.7 33/S-120 7300 0 9.630 10.000 10.000 3.8 34/S-113 7300 0 9.000 9.000 9.000 0 Review is only for conformance with design concept of this project and compliance with the intent of the contract documents. No exceptions observed by: Ronnie Yeoman Make corrections observed by: Page 2 of 5  Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: PST:0341284-35/1 Post Tension Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE,  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX LOUIE LAUCK, Date of Issue: 11/1/2010 Date: Technician: 10/29/2010 Ronnie Yeoman Location: Floor: Tennis Courts #9 and #10 SOG Pour: Serial No. of Gauge: Serial No. of Ram: #1 313993 022101 Strand Heat No: Strand MFG.: N/A N/A Contractor: Schmoldt Construction Approved Drawings : S-1, 3/22/2010 (Strand Placement Shop Drawings) Stressed By: Verified By: American Tennis Courts Ronnie Yeoman TENDON GAUGE PRESSURE CALC MEASURED ELONGATION % NO. ELONG JACKING LIFT OFF END 1 END 2 TOTAL 35/S-106 7300 0 8.500 8.880 8.880 4.5 36/S-105 7300 0 8.250 8.380 8.380 1.6 37/S-112 7300 0 8.750 9.000 9.000 2.9 38/S-119 7300 0 9.250 9.500 9.500 2.7 39/S-126 7300 0 9.940 9.630 9.630 -3.1 40/S-126 7300 0 9.940 10.163 10.130 1.9 41/S-126 7300 0 9.940 9.750 9.750 -1.9 42/S-126 7300 0 9.940 10.250 10.250 3.1 43/S-126 7300 0 9.940 10.000 10.000 0.6 44/S-126 7300 0 9.940 10.250 10.250 3.1 44/S-126 7300 0 9.940 9.880 9.880 -0.6 45/S-126 7300 0 9.940 10.130 10.130 1.9 46/S-126 7300 0 9.940 9.750 9.750 -1.9 47/S-126 7300 0 9.940 9.500 9.500 -4.4 48/S-126 7300 0 9.940 10.250 10.250 3.1 49/S-126 7300 0 9.940 10.130 10.130 1.9 50/S-126 7300 0 9.940 10.250 10.250 3.1 Review is only for conformance with design concept of this project and compliance with the intent of the contract documents. No exceptions observed by: Make corrections observed by: Page 3 of 5  Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: PST:0341284-35/1 Post Tension Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE,  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX LOUIE LAUCK, Date of Issue: 11/1/2010 Date: Technician: 10/29/2010 Ronnie Yeoman Location: Floor: Tennis Courts #9 and #10 SOG Pour: Serial No. of Gauge: Serial No. of Ram: #1 313993 022101 Strand Heat No: Strand MFG.: N/A N/A Contractor: Schmoldt Construction Approved Drawings : S-1, 3/22/2010 (Strand Placement Shop Drawings) Stressed By: Verified By: American Tennis Courts Ronnie Yeoman TENDON GAUGE PRESSURE CALC MEASURED ELONGATION % NO. ELONG JACKING LIFT OFF END 1 END 2 TOTAL 52/S-120 7300 0 9.630 10.250 10.250 6.4 53/S-116 7300 0 9.250 9.000 9.000 -2.7 54/S-113 7300 0 9.000 8.500 8.500 -5.6 55/S-113 7300 0 9.000 8.630 8.630 -4.1 56/S-116 7300 0 9.250 9.750 9.750 5.4 57/S-120 7300 0 9.630 10.000 10.000 3.8 58/S-126 7300 0 9.940 10.000 10.000 0.6 59/S-126 7300 0 9.940 10.000 10.000 0.6 60/S-126 7300 0 9.940 9.880 9.880 -0.6 61/S-126 7300 0 9.940 10.250 10.250 3.1 62/S-126 7300 0 9.940 10.500 10.500 5.6 ¨« :­¬¨ 7300 0 9.940 10.130 10.130 1.9 64/S-126 7300 0 9.940 10.000 10.000 0.6 65/S-126 7300 0 9.940 9.500 9.500 -4.4 66/S-126 7300 0 9.940 9.630 9.630 -3.1 ¨§ :­¬¨ 7300 0 9.940 9.630 9.630 -3.1 68/S-126 7300 0 9.940 9.630 9.630 -3.1 Review is only for conformance with design concept of this project and compliance with the intent of the contract documents. No exceptions observed by: Ronnie Yeoman Make corrections observed by: Note: Page 4 of 5  Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: PST:0341284-35/1 Post Tension Report Issue No:1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS, LEE STONE,  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX LOUIE LAUCK, Date of Issue: 11/1/2010 Date: Technician: 10/29/2010 Ronnie Yeoman Location: Floor: Tennis Courts #9 and #10 SOG Pour: Serial No. of Gauge: Serial No. of Ram: #1 313993 022101 Strand Heat No: Strand MFG.: N/A N/A Contractor: Schmoldt Construction Approved Drawings : S-1, 3/22/2010 (Strand Placement Shop Drawings) Stressed By: Verified By: American Tennis Courts Ronnie Yeoman TENDON GAUGE PRESSURE CALC MEASURED ELONGATION % NO. ELONG JACKING LIFT OFF END 1 END 2 TOTAL 69/S-126 7300 0 9.940 9.750 9.750 -1.9 70/S-119 7300 0 9.250 9.130 9.130 -1.3 71/S-112 7300 0 8.750 8.250 8.250 -5.7 72/S-105 7300 0 8.130 8.500 8.500 4.6 73/S-59 7300 0 4.500 4.750 4.750 5.6 74/S-52 7300 0 4.000 4.130 4.130 3.0 75/S-45 7300 0 3.500 3.380 3.380 -3.4 Review is only for conformance with design concept of this project and compliance with the intent of the contract documents. No exceptions observed by: Ronnie Yeoman Make corrections observed by: equivalent decimal fraction. Remarks: Page 5 of 5