Tennis Ctr Exp-LR101110Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: CON:0341284-28-C4 Concrete Test Report Issue No: 2 Client:CC: SCHMOLDT CONSTRUCTIONCARY SCHMOLDT These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may 5797 CR 126, SUITE ACHRIS HOUSE not be reproduced, except in full, without written permission by CELINA, 75009GEORGE MARSHAL Professional Service Industries, Inc. HILLARY WHITE JOHN ELIAS Project: COPPELL TENNIS CENTERJOHN FIELDER COPPELL, TX LARRY DAVIS Approved Signatory: Ronald Yeoman (Project Manager) LEE STONE Date of Issue:11/10/2010 Mix Data Supplier REDI-MIX Mix Identification 10J11504 Specified Design Strength (psi) 3000at age28days Details of Sample Date SampledDate ReceivedMeasuredSpecified 10/8/2010 Slump (in) 4.75 General LocationSlab on GradeSlump w/ plasticizer (in) N/A 10'N, 5'E of SW Corner of Court # 11 Sample LocationAir Temp (°F) 57 Curing MethodConcrete Temp (°F) 61 ASTM C 1064 Field Sample NoField Cure Temp (°F)HighAir Content (%) 4.80 ASTM C 231 LowUnit Weight (pcf) ASTM C 138 ContractorBatch Size (yd³) 10 Truck No.Ticket No.Water Added (gal)Before 137125255931 Sampled ByAfter Kirk See Submitted ByTime Batched17:21 Kirk See WeatherTime Sampled18:00 Mild and Clear Est. Wind (mph)Yd³ Placed320.0Time Placed17:58 Est. Rh (%)Time In Truck (mins)37 Compressive Strength of Concrete CylindersASTM C 39 Specimen IDDate TestedAgeDimensions (in)Area (in²)Type ofUltimateType ofCompressiveRequired (days)CapLoad (lbf)FractureStrength (psi)Strength (psi) DiameterHeight 0341284-28-C4\110/15/1074.008.0012.57U2984022370 0341284-28-C4\210/15/1074.008.0012.57U2696022150 0341284-28-C4\311/05/10284.008.0012.57U39620231503000 0341284-28-C4\411/05/10284.008.0012.57U40650232303000 NotesRemarks 1.Sampling to ASTM C 172FailureMode: 2 = C39: Vert crack/ cone opposite end; C1314: Cone & Shear 2.Specimen(s) Prepared to ASTM C 31 3.Capping B=Bonded ASTM C 617, U=Unbonded ASTM C 1231, C = Combined Form No: 18970.V1.00, Report No: CON:0341284-28-C4(c) 2000-2009 QESTLab by SpectraQEST.com Page 1 of 1 Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: SDFR:0341284-36/1 Summary Daily Field Report Issue: 1  CARY SCHMOLDT, Client: CC: These test results apply only to the specific locations and materials noted and SCHMOLDT CONSTRUCTION may not represent any other locations or elevations. This report may not be CHRIS HOUSE, 5797 CR 126, SUITE A reproduced, except in full, without written permission by Professional Service GEORGE MARSHAL, Industries, Inc. HILLARY WHITE, CELINA, 75009  JOHN ELIAS, JOHN FIELDER, LARRY Project: COPPELL TENNIS CENTER DAVIS  Approved Signatory: Ronald Yeoman (Project Manager) COPPELL TX Date of Issue: 11/10/2010  Date: 11/8/2010 WEATHER: CLEAR TEMPERATURE RANGE: TO 70 75 PSI REPRESENTATIVE: KIRK SEE TYPE OF INSPECTION BEING PERFORMED SOILS CONCRETE FOUNDATIONS BATCH PLANT CONTROLLED FILL (COMPACTION) PLACEMENT (JOB SITE) ASPHALT OTHER BATCH PLANT FIREPROOFING PLACEMENT (JOB SITE) BRIEF RESUME OF WORK ACCOMPLISHED THIS DATE: On this date, a PSI representative traveled to the above referenced project to perform an visual observation on fireproofing insulation for the clubhouse addition. Technician observed that the insulation being used in the ceiling was R-22 and R-30. R-21 was observed in the addition walls. These items were placed and meet the requirements of the plans and specifications provided at the time of inspection. Due to scheduling conflicts with short notice of pour time and concrete being late to project technician left cylinder molds with contractor on site to be filled by contractor. The items being placed are piers. Cylinders will be picked up on the following day. Page 1 of 1  Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: CON:0341284-28-C3 Concrete Test Report Issue No: 2 Client:CC: SCHMOLDT CONSTRUCTIONCARY SCHMOLDT These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may 5797 CR 126, SUITE ACHRIS HOUSE not be reproduced, except in full, without written permission by CELINA, 75009GEORGE MARSHAL Professional Service Industries, Inc. HILLARY WHITE JOHN ELIAS Project: COPPELL TENNIS CENTERJOHN FIELDER COPPELL, TX LARRY DAVIS Approved Signatory: Ronald Yeoman (Project Manager) LEE STONE Date of Issue:11/10/2010 Mix Data Supplier REDI-MIX Mix Identification 10J11504 Specified Design Strength (psi) 3000at age28days Details of Sample Date SampledDate ReceivedMeasuredSpecified 10/8/2010 Slump (in) 4.50 General LocationSlab on GradeSlump w/ plasticizer (in) N/A 110'S, 20'E of NW Corner of Court # 11 Sample LocationAir Temp (°F) 57 Curing MethodConcrete Temp (°F) 63 ASTM C 1064 Field Sample NoField Cure Temp (°F)HighAir Content (%) 4.70 ASTM C 231 LowUnit Weight (pcf) ASTM C 138 ContractorBatch Size (yd³) 10 Truck No.Ticket No.Water Added (gal)Before 138325255887 Sampled ByAfter Kirk See Submitted ByTime Batched16:37 Kirk See WeatherTime Sampled17:10 Mild and Clear Est. Wind (mph)Yd³ Placed250.0Time Placed17:03 Est. Rh (%)Time In Truck (mins)26 Compressive Strength of Concrete CylindersASTM C 39 Specimen IDDate TestedAgeDimensions (in)Area (in²)Type ofUltimateType ofCompressiveRequired (days)CapLoad (lbf)FractureStrength (psi)Strength (psi) DiameterHeight 0341284-28-C3\110/15/1074.008.0012.57U3946023140 0341284-28-C3\210/15/1074.008.0012.57U3944023140 0341284-28-C3\311/05/10284.008.0012.57U50480240203000 0341284-28-C3\411/05/10284.008.0012.57U55260244003000 NotesRemarks 1.Sampling to ASTM C 172FailureMode: 2 = C39: Vert crack/ cone opposite end; C1314: Cone & Shear 2.Specimen(s) Prepared to ASTM C 31 3.Capping B=Bonded ASTM C 617, U=Unbonded ASTM C 1231, C = Combined Form No: 18970.V1.00, Report No: CON:0341284-28-C3(c) 2000-2009 QESTLab by SpectraQEST.com Page 1 of 1 Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: CON:0341284-28-C2 Concrete Test Report Issue No: 2 Client:CC: SCHMOLDT CONSTRUCTIONCARY SCHMOLDT These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may 5797 CR 126, SUITE ACHRIS HOUSE not be reproduced, except in full, without written permission by CELINA, 75009GEORGE MARSHAL Professional Service Industries, Inc. HILLARY WHITE JOHN ELIAS Project: COPPELL TENNIS CENTERJOHN FIELDER COPPELL, TX LARRY DAVIS Approved Signatory: Ronald Yeoman (Project Manager) LEE STONE Date of Issue:11/10/2010 Mix Data Supplier REDI-MIX Mix Identification 10J11504 Specified Design Strength (psi) 3000at age28days Details of Sample Date SampledDate ReceivedMeasuredSpecified 10/8/2010 Slump (in) 4.25 General LocationSlab on GradeSlump w/ plasticizer (in) N/A 15'N, 30'W of SE Corner of Court # 12 Sample LocationAir Temp (°F) 58 Curing MethodConcrete Temp (°F) 66 ASTM C 1064 Field Sample NoField Cure Temp (°F)HighAir Content (%) 5.00 ASTM C 231 LowUnit Weight (pcf) ASTM C 138 ContractorBatch Size (yd³) 10 Truck No.Ticket No.Water Added (gal)Before 134925255843 Sampled ByAfter Kirk See Submitted ByTime Batched15:33 Kirk See WeatherTime Sampled16:09 Mild and Clear Est. Wind (mph)Yd³ Placed130.0Time Placed16:05 Est. Rh (%)Time In Truck (mins)32 Compressive Strength of Concrete CylindersASTM C 39 Specimen IDDate TestedAgeDimensions (in)Area (in²)Type ofUltimateType ofCompressiveRequired (days)CapLoad (lbf)FractureStrength (psi)Strength (psi) DiameterHeight 0341284-28-C2\110/15/1074.008.0012.57U4411033510 0341284-28-C2\210/15/1074.008.0012.57U4332023450 0341284-28-C2\311/05/10284.008.0012.57U57020245403000 0341284-28-C2\411/05/10284.008.0012.57U55750244403000 NotesRemarks 1.Sampling to ASTM C 172FailureMode: 2 = C39: Vert crack/ cone opposite end; C1314: Cone & Shear, 3 = C39: Vert 2.Specimen(s) Prepared to ASTM C 31cracking/no cones; C1314: Cone & Split 3.Capping B=Bonded ASTM C 617, U=Unbonded ASTM C 1231, C = Combined Form No: 18970.V1.00, Report No: CON:0341284-28-C2(c) 2000-2009 QESTLab by SpectraQEST.com Page 1 of 1 Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: CON:0341284-28-C1 Concrete Test Report Issue No: 2 Client:CC: SCHMOLDT CONSTRUCTIONCARY SCHMOLDT These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may 5797 CR 126, SUITE ACHRIS HOUSE not be reproduced, except in full, without written permission by CELINA, 75009GEORGE MARSHAL Professional Service Industries, Inc. HILLARY WHITE JOHN ELIAS Project: COPPELL TENNIS CENTERJOHN FIELDER COPPELL, TX LARRY DAVIS Approved Signatory: Ronald Yeoman (Project Manager) LEE STONE Date of Issue:11/10/2010 Mix Data Supplier REDI-MIX Mix Identification 10J11504 Specified Design Strength (psi) 3000at age28days Details of Sample Date SampledDate ReceivedMeasuredSpecified 10/8/2010 Slump (in) 6.50 General LocationSlab on GradeSlump w/ plasticizer (in) N/A 10'S, 20'W of NE Corner of Court # 12 Sample LocationAir Temp (°F) 58 Curing MethodConcrete Temp (°F) 62 ASTM C 1064 Field Sample NoField Cure Temp (°F)HighAir Content (%) 4.90 ASTM C 231 LowUnit Weight (pcf) ASTM C 138 ContractorBatch Size (yd³) 10 Truck No.Ticket No.Water Added (gal)Before 137725255805 Sampled ByAfter Kirk See Submitted ByTime Batched14:29 Kirk See WeatherTime Sampled15:00 Mild and Clear Est. Wind (mph)Yd³ Placed30.0Time Placed15:11 Est. Rh (%)Time In Truck (mins)42 Compressive Strength of Concrete CylindersASTM C 39 Specimen IDDate TestedAgeDimensions (in)Area (in²)Type ofUltimateType ofCompressiveRequired (days)CapLoad (lbf)FractureStrength (psi)Strength (psi) DiameterHeight 0341284-28-C1\110/15/1074.008.0012.57U4107023270 0341284-28-C1\210/15/1074.008.0012.57U3980023170 0341284-28-C1\311/05/10284.008.0012.57U51120240703000 0341284-28-C1\411/05/10284.008.0012.57U49880239703000 NotesRemarks 1.Sampling to ASTM C 172FailureMode: 2 = C39: Vert crack/ cone opposite end; C1314: Cone & Shear 2.Specimen(s) Prepared to ASTM C 31 3.Capping B=Bonded ASTM C 617, U=Unbonded ASTM C 1231, C = Combined Form No: 18970.V1.00, Report No: CON:0341284-28-C1(c) 2000-2009 QESTLab by SpectraQEST.com Page 1 of 1 Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F-03307 Phone: (214) 330-9211 Fax: (214) 333-2853 Report No: CON:0341284-27-C1 Concrete Test Report Issue No: 2 Client:CC: SCHMOLDT CONSTRUCTIONCARY SCHMOLDT These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may 5797 CR 126, SUITE ACHRIS HOUSE not be reproduced, except in full, without written permission by CELINA, 75009GEORGE MARSHAL Professional Service Industries, Inc. HILLARY WHITE JOHN ELIAS Project: COPPELL TENNIS CENTERJOHN FIELDER COPPELL, TX LARRY DAVIS Approved Signatory: Ronald Yeoman (Project Manager) LEE STONE Date of Issue:11/10/2010 Mix Data Supplier Lattimore Materials Mix Identification 5077 Specified Design Strength (psi) 3000at age28days Details of Sample Date SampledDate ReceivedMeasuredSpecified 10/7/2010 Slump (in) 1.00 General LocationLight Pole BasesSlump w/ plasticizer (in) N/A SW Pole for Practice Court Sample LocationAir Temp (°F) 81 Curing MethodConcrete Temp (°F) 83 ASTM C 1064 Field Sample NoField Cure Temp (°F)HighAir Content (%) 4.70 ASTM C 231 LowUnit Weight (pcf) ASTM C 138 ContractorBatch Size (yd³) 9 Truck No.Ticket No.Water Added (gal)Before 70373283180 Sampled ByAfter Kirk See Submitted ByTime Batched13:05 Kirk See WeatherTime Sampled14:10 Mild and Clear Est. Wind (mph)Yd³ Placed9.0Time Placed14:28 Est. Rh (%)Time In Truck (mins)83 Compressive Strength of Concrete CylindersASTM C 39 Specimen IDDate TestedAgeDimensions (in)Area (in²)Type ofUltimateType ofCompressiveRequired (days)CapLoad (lbf)FractureStrength (psi)Strength (psi) DiameterHeight 0341284-27-C1\110/14/1076.0012.0028.27U5976032110 0341284-27-C1\210/14/1076.0012.0028.27U6126022170 0341284-27-C1\311/04/10286.0012.0028.27U87690231003000 0341284-27-C1\411/04/10286.0012.0028.27U85610230303000 NotesRemarks 1.Sampling to ASTM C 172FailureMode: 2 = C39: Vert crack/ cone opposite end; C1314: Cone & Shear, 3 = C39: Vert 2.Specimen(s) Prepared to ASTM C 31cracking/no cones; C1314: Cone & Split 3.Capping B=Bonded ASTM C 617, U=Unbonded ASTM C 1231, C = Combined Form No: 18970.V1.00, Report No: CON:0341284-27-C1(c) 2000-2009 QESTLab by SpectraQEST.com Page 1 of 1