SW0801-LR101213GtOTECHNICML GR UP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C10 -1036 Date Sampled: 11/11/2010 Report Date: 12/13/2010 Previously Reported: 12/10/2010 Sampled By: Gatton, Tim Project: Sidewalk Improvements By Order Of: Client Location: Denton Tapp Order Number: 1770 Client: The City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 94795 Test Method: See Below TEST RESULTS Set: 1 of 2 Material: CONCRETE Location: Driveway approaches N.bound Denton Tapp Report No: 94795 Page 1 of 2 Number of Specimens: 4 Compressive Average Strength Strength (PSI) (PSI) Comments 4,270 4,270 5,680 5,510 5,590 HOLD (see remarks) - Maximum Spec Age Tested Diameter Area Load Cure Nbr (days) (in) (in 2) (Ibs) Break Type Loc A 7 4.00 12.57 53,710 Type 2 Lab B 28 4.00 12.57 71,330 Type 2 Lab C 28 4.00 12.57 69,275 Type 3 Lab D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,600 psi @ 28 days Report No: 94795 Page 1 of 2 Number of Specimens: 4 Compressive Average Strength Strength (PSI) (PSI) Comments 4,270 4,270 5,680 5,510 5,590 HOLD (see remarks) - Quantity Represented: 10 cu. yds. Remarks: Sampled: South driveway approach to Grow It Nursery Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Ong: The City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group r Perry G. Kakara, Sr. Proiect Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,600 psi @ 28 days MEETS REFERENCE VALUE Date Received: 11/12/2010 Slump: 5.0 Inches Transported By: Redi -Mix Curing Method: Standard Air Content: 6.0% Source /Sampled At: Truck / Center Time Sampled: 12:05 pm Plant: Redi -Mix -Plant #P136 Temp.: Ambient: 77 °F Mix: 76 °F Mix Code: 101-11504 Truck/Ticket No: 1183 / 25267647 Quantity Represented: 10 cu. yds. Remarks: Sampled: South driveway approach to Grow It Nursery Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Ong: The City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group r Perry G. Kakara, Sr. Proiect Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. GEOTECHNICIfiL GROUff Acct ID: 1770 Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 1W0►W4 a [IN [1XZ:9 Report Date: 12/13/2010 Previously Reported: 12/10/2010 Project: Sidewalk Improvements Location: Denton Tapp Date Sampled: 11/11/2010 Sampled By: Gatton, Tim By Order Of: Client Order Number: 1770 Client: The City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 94795 Test Method: See Below TEST RESULTS Report No: 94795 Page 2 of 2 Set: 2 of 2 Material: CONCRETE Number of Specimens: 4 Location: Sidewalk N.bound Denton Tapp Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nor (days) (in) (in') (lbs) Break Type Loc (PSI) (PSI) Comments A 7 4.00 12.57 48,775 Type 2 Lab 3,880 3,880 B 28 4.00 12.57 64,590 Type 3 Lab 5,140 C 28 4.00 12.57 64,885 Type 2 Lab 5,160 5 D HOLD (see remarks) - Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,000 psi @ 28 days MEETS REFERENCE VALUE Date Received: 11/12/2010 Slump: 4.5 Inches Transported By: Redi -Mix Curing Method: Standard Air Content: 5.7% Source /Sampled At: Truck / Center Time Sampled: 12:49 pm Plant: Redi -Mix -Plant #P136 Temp.: Ambient: 80 °F Mix: 79 °F Mix Code: 10J11504 Truck/Ticket No: 1193 / 25267697 Quantity Represented: 10 cu, yds. Remarks: Sampled 120' South of driveway to Grow It Nursery Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Orig: The City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.