Loading...
SW0801-LR101216I� fiLLI ry OEOTECHNICML GROUr Consulting Engineering * Ceotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C10 -1036 Date Sampled: 12/07/2010 Report Date: 12/16/2010 Sampled By: Wingerd, Pierce Project: Sidewalk Improvements By Order Of: Larry Davis Location: Entrance into United Community Bank on Denton Tap. S. of Order Number: 1770 Sandy Lake Rd Number of Client: The City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 95634 Material: CONCRETE Test Method: See Below TEST RESULTS Report No: 95634 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nbr (days) (in) (in') (lbs) Break Type LOG (PSI) (PSI) Comments A 7 4.00 12.57 67,965 Type 2 Lab 5,410 5,410 B 28 4.00 12.57 Lab C 28 4.00 12.57 Lab D HOLD (see remarks) - _IEf_til C� (111 �_ I r`11 C_ [_1111_­_ l I __I Type 1 Type 2 Type 3 Type 4 _` ---- Type 5 Type 6 Specification: 3,600 psi @ 28 days Date Received: 12/08/2010 Slump: 4.0 Inches Transported By: Redi -Mix Curing Method: Standard Air Content: 3.6% Source /Sampled At: Truck / Center Time Sampled: 10:50 am Plant: Redi -Mix - Plant #259 Temp.: Ambient: 53 °F Mix: 61 °F Mix Code: 1 01_1 1504 Truck/Ticket No: 1375 / 25275848 Quantity Represented: 10 cu. yds. Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Orig: The City of Coppell (Coppell, TX) Attn: Mr, Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Acct ID: 1770 Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 File No: C10 -1036 Report Date: 12/16/2010 Previously Reported: 11/29/2010 Project: Sidewalk Improvements Location: N.bound Denton Tap sidewalk from 220 Denton Tap to Braewood Dr. Client: The City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST Date Sampled: 11/17/2010 Sampled By: Wingerd, Pierce By Order Of: Larry Davis Order Number: 1770 Number of Specime 4 LAB NO: 95002 Material: CONCRETE Test Method: See Below TEST RESULTS Report No: 95002 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nbr (days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) Comments A 7 4.00 12.57 41,990 Type 2 Lab 3,340 3,340 B 28 4.00 12.57 59,395 Type 2 Lab 4,730 C 28 4.00 12.57 59,485 Type 2 Lab 4,730 4,730 D HOLD (see remarks) - I \-.7 I �Tli Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,000 psi @ 28 days Date Received: 11/18/2010 Slump: 5.5 Inches Transported By: Redi -Mix Curing Method: Standard Air Content: 4.2% Source /Sampled At: Truck / Center Time Sampled: 12:15 pm Plant: Redi -Mix - Plant #P136 Temp.: Ambient: 68 °F Mix: 75 °F Mix Code: 10J11504 Truck/Ticket No: 1168 / 25269365 Quantity Represented: 10 cu. yds. Remarks: *Slump exceeds specifications Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Ong: The City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.