SW0801-LR110103OLLInNICE GEOT GROUr Acct I D: 1770 Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 File No: C10 -1036 Report Date: 01/03/2011 Project: Sidewalk Improvements Location: Sidewalk and drive on Denton Tap northbound drive into Braewood Shopping Center on Denton Tap south of Sandy Lake, Centerline of drive Date Sampled: 12/01/2010 Sampled By: Wingerd, Pierce By Order Of: Larry Davis Order Number: 1770 Quantity Represented: 5 Cu. yds. at 10 cu. yds. placed of a 30 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Orig: The City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group t� Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Number of Client: The City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 95491 Material: Concrete Test Method: See Below TEST RESULTS Report No: 95491 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nbr (days) (in) (in') (Ibs) Break Type Loc (PSI) (PSI) Comments A 7 4.00 12.57 59,645 Type 3 Lab 4,750 4,750 B 28 4.00 12.57 75,655 Type 2 Lab 6,020 C 28 4.00 12.57 76,310 Type 4 Lab 6,070 6,050 D HOLD (see remarks) - Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,600 psi @ 28 days Date Received: 12/02/2010 Slump: 5.0 Inches Transported By: Redi -Mix Curing Method: Standard Air Content: 3.8% Source /Sampled At: Truck / Center Time Sampled: 11:05 am Plant: P136 Temp.: Ambient: 55 °F Mix: 63 °F Mix Code: 1 01_1 1504 Truck/Ticket No: 1177 / 25273617 Quantity Represented: 5 Cu. yds. at 10 cu. yds. placed of a 30 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Orig: The City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group t� Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.