Loading...
WA9903-CS000207SHIMEK, JACOBS & FINKLEA, L.L.P. CONSULTING ENGINEERS 8333 Douglas Avenue, #820 Dallas, Texas 75225-5816 Fax (214) 361-0204 ROSS L. JACOBS, P.E. RONALD V. CONWAY, P.E. JOHN W. BIRKHOFF, P.E. JOE R. CARTER, P.E. GARY C. HENDRICKS. P.E I C. FINKLEA, P.E. PAUL A. CARLINE, P.E. MATT HICKEY, P.E. February 7, 2000 Phone (214) 361-7900 Mr. Kenneth M. Griffin, P.E. CiW of Coppell Post Office Box 478 Coppell, Texas 75019 Re: Village Parkway Pump Station - Addition of Pump No. 4 TxU Transformer Replacement Dear Mr. Griffin: We are continuing to work with Texas Utilities to provide the necessary information they require in order to replace the transformers at the Village Parkway Pump Station. Attached is a copy of the electronic mail file we sent to Mr. Rick Fielding at TxU. This copy is provided for your information and files. We are available to discuss this project further at your convenience. Sincere Enclosures cc: Mr. Glen Hollowell, P.E. j'~clerical\coppell\1999-153\letters\corres\k\txu.doc Gary Hendricks From: Sent: To: Subject: Jeff York Thursday, February 03, 2000 11:22 AM Gary Hendricks FW: Coppell P,S. - Location and Load Information ..... Original Message--- From: William Goff [SMTP:billgoff@earthlink.net] Sent: Thursday, February 03, 2000 9:06 AM To: Rick Fielding Cc: Gary Hendricks Subject: Coppell P.S. - Location and Load Information SJF: Please route email copy to Gary Hendricks Rick Fielding, TXU Per our discussion, I have provided four (4) MS Powerpoint files as listed below for our use in assisting the project completion for the upgrade to the (~ity of Coppell Village Parkway P.S. 1. Location map file: Iocation.ppt 2, Single line file: 1-1ine,ppt 3. 2nd single line file: 1-line-b.ppt 4. load summary file: load summary.ppt You indicated in our discussion that you should be able to provide us your requirements or changes (if any) by 5-6 working days from providing the information. We will follow-up with you by the end of next week. Please call if you have any questions or if you need the data sent by mail. Thanks. 1-11ne-b.pl3t load summary.ppt 1-1lne.ppt I 1 480V & 208V ONE LINE DIACRA_M ' ITEM 1 2 3 4 DESCRIPTION HP KVA C.B. AMPS wp-1 water pump no. 1 450 401.08 wp-2 water pump no. 2' ....... 450 .............2~0~.08' ............................. wp-3 water pump no.3 450 40'COB wp-4 water pump no.4 ........................:4'50" ............40T'.08""' ...................... 5 xfmr 6 wp-5 water pump no.5 '/ wp-6 water pump no.6 8 ............................~]t'heater 9 el-4 exhaust fan no.4 10 dry type xfmr .... 500..00' .......... 25"0""227772' 2'~72' .... ........................................................................... 8T6'5 ...................................30 ............................ 3 2.96 Tf2TS0~,. .............. : 'fl ............ '(~51orine equipment skid ...............................................................;1'7729' .........."60 ............................. "f2 uh-1 unit heater no.1 ~ 10.'00~ 10 "'T3 uh-'2 unit heater no.2 ........................t"'TOTO0", .............................10 14 Uh-'3 unit heater no.3 i i0.00"4 ............. 10 ' i'5 el-1 exhaust fan no. 1 2 ..... ~' 16 Ipa Itg phi 43.23 15'0 1 i ef-f-f-~ exhaust fan no.2 ~'2 1.97 " "'~B ~fi3'~haust fan no.3 ......... 2 ......................'T797 ..................:: ................................... "'f9 uh-4 unit heater no.4 10.00 10 20 uh-'5 unit heater no. 5 ....................."t'0T00 ...................10 21 uh-6 unit heater no.6 T~ 10 "22 ~c condensing unit =1'7729 '60' 23 a/c air conditioner unit 1/.29 60 24 ammonia equipment skid "T7.29 60 ........ 25 ....lighting p~ifi~'l'i~i'"'f~ pump room additr6n ........................................q'7:29' ....................60 ........................ KVA Tota I for KVA Total randormers 401.08 401.08 2~0'~1":08 ...............................: ............ 40'~.08 40139'8 .......40~':'0'8 ...............................................40'C0'8' '500.'O'G 227.72 2277~ ...........................................................8;65 .................................................................... 2.96 .......... "~RF2.~ ............................... ~'7':29 ....................................................: .......................... "' 1.97 43.23 1.97 ................... ;1:97 ............................................................ ;[7729 1/729 17729 ........ ;[7:29 ............................................................... I otal kV,~ 2206.95 2216.80 i';::: 'T~tal'kVA'9'0% Load i-actor Tg'BG::2¢ ......... "19'9!{7f2 Note: Items 6 & 7 am low head pump ................ , used for low water winter requirements -- L-- I typically. ' ~ l<e co~~ I' ra nsforme r S~'2000'E~/~ ,IF-~ I ~ IF~ o Pt~-3/SO0 KClL,I2/O G,4"C ~ PI07-312,16 G.3'C ~ ~.14 G,2 t/2'c ~'-"11, t/2'C Pt w-312.~ Uto I1' VF*4 ~.4 _4160V ONE LINE DIAGRAM TANK TOWN(::DIT~ I ~T~ COUN1Y LOCATION MAP ':;:',.,-;:,r~,."=