Loading...
ST0301A-CS100615 (2) Page 1 of 1 Keith Marvin - Bethel Road II, Phase I - Utility Submittal From:   Caleb Thornhill <bct@freese.com> To:   Engineer <Engineer@ci.coppell.tx.us>, Keith Marvin <kmarvin@coppelltx.gov> Date:   6/15/2010 11:21 AM Subject:   Bethel Road II, Phase I - Utility Submittal CC:   Chris Poteet <cjp@freese.com>, CPL03243 <CPL03243@freese.com>   Larry/Keith,   Below is our comments on the submittal package from JRJ Paving at the Traffic Control meeting/discussion.  This is all we have received to date.   1.JM Eagle AWWA C905 DR-18 PVC Water Pipe (16”) – Approved       2.JM Eagle AWWA C900 DR-18 PVC Water Pipe (6”-8”) – Approved       3.Star Pipe Company Ductile Iron Fittings C153 Import – Not approved       a.Fittings are called out as compact fittings and import.  Does not meeting Coppell’s list of approved        materials which call out full size and domestic. 4.Star Pipe Company 664S Valve Box - Approved       5.Mueller Company RW Gate Valves – Not approved       a.Submittals calls out RW.  Coppell and NCTCOG (502.6.2) require RS (resilient seat).        6.Mueller Company NST Fire Hydrant – Approved       7.EBAA Iron Company Series 2000 PV Megalugs – Not approved       a.Verify iron type.  Submittal shows 65-45-12.  NCTCOG calls for 60-42-10.         8.Smith Blair 665 Stainless Steel Tapping Sleeve – Approved       9.Cerro Inc. Type K soft copper (2”) – Approved pending City approval       a.City only allows flared connections.  Bullhead type services will only be used with approval from City        Engineer. 10.APCO 2” 145C.2 Combination Air Release Valve – Approved   11.JM Eagle AWWA SDR35 PVC Pipe (12”) – Approved pending City approval   a.City’s list of approved materials states SDR 35 to 15’ bury depth, plans calls out 15.93’ per topo.        12.Plastic Tends SDR 35 PVC Gasketed Sewer Fittings – Approved pending City approval   a.Verify SDR 35 acceptable per #12.        13.Bass and Hays Foundry 400# Manhole Ring and Cover – Approved   14.The Turner Company 60” Diameter Pre-Cast Manhole – Approved     Please review and call me with any questions you might have.   B. Caleb Thornhill P.E. Project Manager Freese and Nichols, Inc. Main: 214-217-2200  Direct: 214-217-2282  Fax: 214-920-2565  Email: bct@freese.com    This electronic mail message is intended exclusively for the individual or entity to which it is addressed. This message, together with any attachment, may contain the sender's organization's confidential and privileged information. The recipient is hereby notified to treat the information as confidential and privileged and to not disclose or use the information except as authorized by sender's organization. Any unauthorized review, printing, retention, copying, disclosure, distribution, retransmission, dissemination or other use of, or taking of any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited. If you received this message in error, please immediately contact the sender by reply email and delete all copies of the material from any computer. Thank you for your cooperation. file://C:\Documents and Settings\radloo\Local Settings\Temp\XPgrpwise\4C17623CCity_...1/21/2011