Sales Tax 09-LR101216' HLLIHi'iCE
GEOTECHf11CAL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID: 1770 File No: C10 -1013
Report Date: 12/16/2010 Previously Reported: 11/29/2010
Project: Heartz Road
Location: Heartz Road
Client: The City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Date Sampled: 11/17/2010
Sampled By: Spooner, Charles
By Order Of: Larry w/ RKM
Order Number: 1770
LAB NO: 95005
Test Method: See Below
TEST RESULTS
Set: 1 of 2 Material: CONCRETE
Location: Hand paving Heartz Road, stattion 1 +50, center lane
Maximum
Spec
Nbr
A
B
C
D
Age Tested Diameter Area Load
(days) (in) (in') (lbs) Break Tvoe
3
6.00
28.27
7
6.00
28.27
28
6.00
28.27
28
6.00
28.27
148,915
Type 2
Lab
5,270 5,250
Type 1
Specification: 3,600 psi @ 28 days
Date Received: 11/18/2010
Curing Method: Standard
Time Sampled: 10:05 am
Temp.: Ambient: 59 °F Mix: 64 °F
Slump: 4.75 Inches
Air Content: 3.8%
Mix Code: 1 01_1 1504
Transported By: Redi -Mix
Source /Sampled At: Truck / Center
Plant: Redi -Mix - Plant #P259
Truck/Ticket No: 1371 / 25269232
Quantity Represented: 9 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, Sr. Project Manager
Report No: 95005
Page 1 of 2
Number of Specimens: 4
Compressive Average
Cure Strength Strength
Loc (PSI) (PSI) Comments
83,575
Type 2
Lab
2,960 2,960
117,850
Type 2
Lab
4,170 4,170
147,730
Type 1
Lab
5,220
148,915
Type 2
Lab
5,270 5,250
Type 2
Type 3
Type 4
Type 5 Type 6
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
FILLINICE
Acct ID: 1770
Report Date: 12/16/2010
Project: Heartz Road
Location: Heartz Road
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
File No: C10 -1013
Previously Reported: 11/29/2010
Date Sampled: 11/17/2010
Sampled By: Spooner, Charles
By Order Of: Larry w/ RKM
Order Number: 1770
Client: The City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 95005
Test Method: See Below
TEST RESULTS
Report No: 95005
Page 2 of 2
Set: 2 of 2
Material: CONCRETE
Number of Specimens: 4
Location: Hand paving, Heartz Road,
station 4 +50, center lane
Maximum
Compressive Average
Spec Age Tested Diameter
Area
Load Cure
Strength Strength
Nbr (days) (in)
(in 2)
(Ibs) Break Type LOG
(PSI) (PSI) Comments
A 3 6.00
28.27
111,730 Type 2 Lab
3,950 3,950
B 7 6.00
28.27
149,755 Type 2 Lab
5,300 5,300
C 28 6.00
28.27
167,110 Type 2 Lab
5,910
D 28 6.00
28.27
166,485 Type 2 Lab
5,890 5,900
f,�
Type 1
Type 2 Type 3 Type 4
Type 5 Type 6
Specification: 3,600 psi @ 28 days
Date Received: 11/18/2010
Slump: 3.75 Inches
Transported By: Redi -Mix
Curing Method: Standard
Air Content: 4.2%
Source /Sampled At: Truck / Center
Time Sampled: 12:35 pm
Plant: Redi -Mix - Plant #259
Temp.: Ambient: 66 °F Mix: 73 °F
Mix Code: 1 01_1 1504
Truck/Ticket No: 1388 / 25269379
Quantity Represented: 91 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Ong: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
a�
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
FILLInNCE
GEOTECHNICRL
Consulting Engineering * Ceotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID: 1770 File No: C10 -1013
Date Sampled: 11/16/2010
Report Date: 12/16/2010 Previously Reported:
12/15/2010
Sampled By: Hanks, Marvin
Project: Heartz Road
By Order Of: Larry
Location: 145 Heartz Rd, S.bound
Order Number: 1770
Number of
Client: The City of Coppell
Specimens: 5
REPORT: REPORT OF CONCRETE COMPRESSIVE
STRENGTH TEST LAB NO: 94751
Material: CONCRETE
Test Method: See Below
TEST RESULTS
Report No: 94751
Page 1 of 1
Maximum
Compressive Average
Spec Age Tested Diameter Area
Load Cure
Strength Strength
Nor (days) (in) (in')
(Ibs) Break Type Loc
(PSI) (PSI) Comments
A 3 6.00 28.27
106,080 Type 2 Lab
3,750 3,750
B 7 6.00 28.27
134,650 Type 1 Lab
4,760 4,760
C 28 6.00 28.27
164,670 Type 1 Lab
5,820
D 28 6.00 28.27
166,360 Type 2 Lab
5,880 5,850
E
HOLD (see remarks) -
Type 1
Type 2 Type 3 Type 4
Type 5 Type 6
Specification: 3,600 psi @ 28 days
Date Received: 11/17/2010
Slump: 4.5 Inches
Transported By: Redi -Mix
Curing Method: Standard
Air Content: 4.6%
Source /Sampled At: Truck / Center
Time Sampled: 9:05 am
Plant: Redi -Mix
Temp.: Ambient: 52 °F Mix: 67 °F
Mix Code: 10L11504
Truck/Ticket No: N/A / 25268513
Quantity Represented: 10 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, Sr. Project Manager
THIS REPOR "i APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED, THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
ALLInNCE
.,
GEOTECHNIML
GROUr
Acct ID: 1770
Report Date: 12/16/2010
Project: Heartz Road
Location: Heartz Road
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
File No: C10 -1013
Previously Reported: 11/29/2010
Date Sampled: 11 /18/2010
Sampled By: Marvin Hanks
By Order Of: Larry
Order Number: 1770
Client: The City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 95048
Test Method: See Below
TEST RESULTS Report No: 95048
Page 1 of 3
Set: 1 of 3 Material: CONCRETE
Location: S.bound Heartz Rd, east half, sta 5 +55
Quantity Represented: 10 cu. yds.
Number of Specimens: 4
Compressive
Average
Maximum
Strength
(PSI)
Spec Age Tested Diameter
Area
Load
4,730
Cure
Nbr (days) (in)
(in')
(Ibs)
Break
Type Loc
A 3 6.00
28.27
113,370
Type 3
Lab
B 7 6.00
28.27
133,715
Type 2
Lab
C 28 6.00
28.27
163,280
Type 1
Lab
D 28 6.00
28,27
164,410
Type 2
Lab
Type 1
Type 2
Type 3 Type 4
Specification: 3,600 psi @ 28 days
Date Received: 11/19/2010
Slump:
4.25 Inches
Curing Method: Standard
Air Content:
3.4%
Time Sampled: 9:55 am
Temp.: Ambient: 48 °F Mix: 63 ° F
Mix
Code:
101-11504
Quantity Represented: 10 cu. yds.
Number of Specimens: 4
Compressive
Average
Strength
Strength
(PSI)
(PSI) Comments
4,010
4,010
4,730
4,730
5,770
( 5,810
5,790
Type 5 Type 6
Transported By: Redi -Mix
Source /Sampled At: Truck / Center
Plant: Redi -Mix
Truck/Ticket No: N/A / 25269712
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P,E.
Orig: The City of Coppell (Coppell, Tx) Attn: Mr. Keith Marvin, P. E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr, Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
�.M
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE Ol=
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED_ THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
FILLIMICE
GEOTECHNICIMIL
GROUr
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID: 1770 File No: C10 -1013 Date Sampled: 11/18/2010
Report Date: 12/16/2010 Previously Reported: 11/29/2010 Sampled By: Marvin Hanks
Project: Heartz Road By Order Of: Larry
Location: Heartz Road Order Number: 1770
Client: The City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 95048
T Me t h od: See B elow
TEST RESULTS Report No: 95048
Page 2 of 3
Set: 2 of 3 Material: CONCRETE
Location: S.bound Heartz Rd, E. side at 137 Heartz Rd
Quantity Represented: 130 cu. yds.
Number of Specimens: 4
Compressive
Average
Strength
Maximum
(PSI)
Spec Age Tested Diameter
Area
Load
Cure
Nor (days)
(in)
(in 2)
(Ibs)
Break Type Loc
A 3
6.00
28.27
101,805
Type 1 Lab
B 7
6.00
28.27
135,415
Type 1 Lab
C 28
6.00
28.27
147,385
Type 2 Lab
D 28
6.00
28.27
149,445
Type 2 Lab
P-_
1 'J,
Type 1
Type 2
Type 3 Type 4
Specification:
3,600 psi @ 28 days
Date Received:
11/19/2010
Slump: 4.5 Inches
Curing Method:
Standard
Air Content: 4.3%
Time Sampled:
12:30 pm
Temp.: Ambient:
54 °F Mix: 69 °F
Mix Code: 1 01_1 1504
Quantity Represented: 130 cu. yds.
Number of Specimens: 4
Compressive
Average
Strength
Strength
(PSI)
(PSI) Comments
3,600
3,600
4,790
4,790
5,210
l (5,290
1 5,250
Type 5 Type 6
Transported By: Redi -Mix
Source /Sampled At: Truck / Center
Plant: Redi -Mix
Truck/Ticket No: N/A / 25269891
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P. E.
Ong: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P,E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICAIIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
MLLIMICE
A - � GEOTECHNICML
GROUr
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID: 1770
File No: C10 -1013
Date Sampled: 11/18/2010
Report Date: 12/16/2010 Previously Reported: 11/29/2010
Sampled By: Marvin Hanks
Project: Heartz Road
By Order Of: Larry
Location: Heartz Road
Order Number: 1770
Client: The City of Coppell
REPORT: REPORT OF CONCRETE
COMPRESSIVE STRENGTH TEST LAB NO: 95048
Test Method: See Below
TEST RESULTS
Report No: 95048
Page 3 of 3
Set: 3 of 3
Material: CONCRETE
Number of Specimens: 4
Location: S.bound Heartz Rd, E. side, at 149 Heartz Rd
Maximum
Compressive Average
Spec Age Tested Diameter
Area Load Cure
Strength Strength
Nbr (days) (in)
(in') (Ibs) Break Type Loc
(PSI) (PSI) Comments
A 3 6.00
28.27 107,875 Type 2 Lab
3,820 3,820
B 7 6.00
28.27 135,000 Type 1 Lab
4,770 4,770
C 28 6.00
28.27 159,875 Type 1 Lab
5,650
D 28 6.00
28.27 159,370 Type 2 Lab
5,640 5,650
Type 1 Type 2 Type 3 Type 4
Type 5 Type 6
Specification: 3,600 psi @ 28 days
Date Received: 11/19/2010
Slump: 4.5 Inches
Transported By: Redi -Mix
Curing Method: Standard
Air Content: 4.6%
Source /Sampled At: Truck / Center
Time Sampled: 1:30 pm
Plant: Redi -Mix
Temp.: Ambient: 57 °F Mix: 69 °F
Mix Code: 1 01_1 1504
Truck/Ticket No:
Quantity Represented: 200 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppeil Attn: Mr. Keith Marvin, P.E.
Ong: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adioo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,