Sales Tax 09-LR101221IIII
GEOTECHNICML
..o
Acct ID:
1770
Report Date:
12/21/2010
Project:
Heartz Road
Location:
Heartz Road
Consulting Engineering * Ceotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
File No: C10 -1013 Date Sampled: 12/16/2010
Sampled By: Hanks, Marvin
By Order Of: Cruz w /RKM
Order Number: 1770
Client: The City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 96054
Test Method: See Below
TEST RESULTS
Report No: 96054
Page 1 of 3
Set: 1 of 3 Material: CONCRETE
Number of Specimens: 4
Location: N.bound Heartz Rd, station 1 +95
Maximum
Compressive Average
Spec Age Tested Diameter Area
Load Cure
Strength Strength
Nbr (days) (in) (in')
(lbs) Break Type Loc
(PSI) (PSI) Comments
A 4 6.00 28.27
100,450 Type 2 Lab
3,550 3,550
B 7 6.00 28.27
Lab
C 28 6.00 28.27
Lab
D 28 6.00 28.27
Lab
_....� �._....._.
, ......
i
L ...I
Type 1
Type 2 Type 3 Type 4
Type 5 Type 6
Specification: 3,600 psi @ 28 days
Date Received: 12/17/2010
Slump: 4.5 Inches
Transported By: Redi -Mix
Curing Method: Standard
Air Content: 4.1%
Source /Sampled At: Truck / Center
Time Sampled: 9:05 am
Plant: Redi -Mix
Temp.: Ambient: 43 °F Mix: 54 °F
Mix Code: 1 OL11504
Truck/Ticket No: N/A / 25279300
Quantity Represented: 10 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and 0138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Ong: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
GROUr
Acct ID: 1770
Report Date: 12/21/2010
Project: Heartz Road
Location: Heartz Road
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
File No: C10 -1013 Date Sampled: 12/16/2010
Sampled By: Hanks, Marvin
By Order Of: Cruz w /RKM
Order Number: 1770
Client: The City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 96054
T est Method: See B
TEST RESULTS
Report No: 96054
Page 2 of 3
Set: 2 of 3
Material: CONCRETE
Number of Specimens: 4
Location: N.bound Heartz Road at 117 Heartz Rd
Maximum
Compressive Average
Spec Age Tested Diameter
Area
Load Cure
Strength Strength
Nbr (days) (in)
(in 2)
(Ibs) Break Type Loc
(PSI) (PSI) Comments
A 4 6.00
28.27
114,100 Type 1 Lab
4,040 4,040
B 7 6.00
28.27
Lab
C 28 6.00
28.27
Lab
D 28 6.00
28.27
Lab
Type 1
Type 2 Type 3 Type 4
Type 5 Type 6
Specification: 3,600 psi @ 28 days
Date Received: 12/17/2010
Slump: 4.0 Inches
Transported By: Redi -Mix
Curing Method: Standard
Air Content: 4.5%
Source /Sampled At: Truck / Center
Time Sampled: 10:47 am
Plant: Redi -Mix
Temp.: Ambient: 45 °F Mix: 56 °F
Mix Code: 1 01_1 1504
Truck/Ticket No: N/A / 25279439
Quantity Represented: 110 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin: P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
FILLIMICE
G EOTECHNICIfiL
GROur
Acct ID: 1770
Report Date: 12/21/2010
Project: Heartz Road
Location: Heartz Road
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
File No: C10 -1013 Date Sampled: 12/16/2010
Sampled By: Hanks, Marvin
By Order Of: Cruz w /RKM
Order Number: 1770
Client: The City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 96054
Te M See Below
TEST RESULTS Report No: 96054
Page 3 of 3
Set: 3 of 3 Material: CONCRETE
Location: N.bound Heartz Rd at 133 Heartz Rd
Maximum
Spec Age Tested Diameter
Area
Nor (days) (in)
(in')
A 4 6.00
28.27
B 7 6.00
28.27
C 28 6.00
28.27
D 28 6.00
28.27
Lab
Type 1
Specification: 3,600 psi @ 28 days
Date Received: 12/17/2010
Curing Method: Standard
Time Sampled: 12:49 pm
Temp.: Ambient: 50 °F Mix: 56 °F
Load
(Ibs) Break Type
107,675 Type 2
Number of Specimens: 4
Type 2 Type 3 Type 4 Type 5 Type 6
Slump: 4.5 Inches Transported By: Redi -Mix
Air Content: 4.6% Source /Sampled At: Truck / Center
Plant: Redi -Mix
Mix Code: 101_11504 Truck/Ticket No: N/A / 25279542
Quantity Represented: 210 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E,
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
f
� k ,
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Compressive
Average
Cure
Strength
Strength
Loc
(PSI)
(PSI) Comments
Lab
3,810
3,810
Lab
Lab
Lab
Type 2 Type 3 Type 4 Type 5 Type 6
Slump: 4.5 Inches Transported By: Redi -Mix
Air Content: 4.6% Source /Sampled At: Truck / Center
Plant: Redi -Mix
Mix Code: 101_11504 Truck/Ticket No: N/A / 25279542
Quantity Represented: 210 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E,
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
f
� k ,
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
IIII III
GROUr
Acct I D:
Report Date
Project:
Location:
1770
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
File No: C10 -1013
12/21/2010
Heartz Road
Inlet depressions and manhole tops along S.bound Heartz Dr
Date Sampled: 12/13/2010
Sampled By: Hanks, Marvin
By Order Of: Ricardo
Order Number: 1770
Number of
Client: The City of Coppell Specimens: 4
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 95893
Material: CONCRETE
Test Method: See Below
Quantity Represented:
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39,
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
TEST RESULTS
Report No: 95893
Page 1 of 1
Maximum
Compressive Average
Spec Age Tested Diameter
Area
Load Cure
Strength Strength
Nbr (days) (in)
(in')
(Ibs) Break Type LOG
(PSI) (PSI) Comments
A 7 6.00
28.27
132,005 Type 1 Lab
4,670 4,670
B 28 6.00
28.27
Lab
C 28 6.00
28.27
Lab
D
HOLD (see remarks) -
I .._... -J
............
Type 1
Type 2 Type 3 Type 4
Type 5 Type 6
Specification: 3,600 psi @ 28 days
Date Received: 12/14/2010
Slump: 4.0 Inches
Transported By: Redi -Mix
Curing Method: Standard
Air Content: 4.2%
Source /Sampled At: Truck / Center
Time Sampled: 1:10 pm
Plant: Redi -Mix
Temp.: Ambient: 47 °F Mix: 56 °F
Mix Code: 1 01_1 1504
Truck/Ticket No: N/A / 25277885
Quantity Represented:
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173,
C1064 and C138. Compressive strength tests per ASTM C39,
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Orig: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
GEOTECHNICtIlL
Acct ID: 1770
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
File No: C10 -1013
Report Date: 12/21/2010 Previously Reported: 11/29/2010
Project: Heartz Road
Location: Southbound right lane of Heartz Rd. at Station 6 +50 and 4 +00
Date Sampled: 11/22/2010
Sampled By: Whitney, Steve
By Order Of: Cruz
Order Number: 1770
Quantity Represented: 7 cu. yds. at 7 cu. yds. placed of a 7 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or 0173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Ong: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
r ,
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED, THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Number of
Client: The City of Coppell
Specimens: 4
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 95144
Material: Concrete
Test Method: See Below
TEST RESULTS
Report No: 95144
Page 1 of 1
Maximum
Compressive Average
Spec Age Tested Diameter
Area
Load Cure
Strength Strength
Nbr (days) (in)
(in')
(lbs) Break Type Loc
(PSI) (PSI) Comments
A 4 6.00
28.27
109,960 Type 2 Lab
3,890 3,890
B 7 6.00
28.27
114,560 Type 1 Lab
4,050 4,050
C 28 6.00
28.27
137,365 Type 2 Lab
4,860
D 28 6.00
28.27
1 Type 2 Lab
4,870
]
( 4,88 ) 0
1
Type 1
Type 2 Type 3 Type 4
Type 5 Type 6
Specification: 3,600 psi @ 28 days
Date Received: 11/23/2010
Slump: 5.0 Inches
Transported By: LMC
Curing Method: Standard
Air Content: 3.5%
Source /Sampled At: Truck / Center
Time Sampled: 10:20 am
Plant: 6
Temp.: Ambient: 72 °F Mix: 77 °F
Mix Code: 8097
Truck/Ticket No: 7008 / 6381105
Quantity Represented: 7 cu. yds. at 7 cu. yds. placed of a 7 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or 0173,
C1064 and C138. Compressive strength tests per ASTM C39.
Charge: The City of Coppell Attn: Mr. Keith Marvin, P.E.
Ong: The City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
(1 -cc copy)
1 -cc The City of Coppell Attn: Rhonda Adloo
1 -cc The City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
r ,
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED, THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.